A correction for powder diffraction peak asymmetry due to axial divergence
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Analysis of a crystal structure using the Rietveld profile technique requires a suitable description of the shape of the peaks. In general, modern refinement codes include accurate formulations for most effects; however, the functions used for peak asymmetry are semi-empirical and take very little account of diffraction optics. The deficiencies in these methods are most obvious for high-resolution instruments. This study describes the implementation of powder diffraction peak profile formulations devised by van Laar & Yelon [J. Appl. Cryst. (1984), 17, 47–54]. This formalism, which describes the asymmetry due to axial divergence in terms of finite sample and detector sizes, does not require any free parameters and contains intrinsic corrections for the angular dependence of the peak shape. The method results in an accurate description of the observed profiles for a variety of geometries, including conventional X-ray diffractometers, synchrotron instruments with or without crystal analyzers and neutron diffractometers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Savitzky-Golay Smoothing Filters
Press, W. H., & Teukolsky, S. A. (1990) · Computers in Physics · doi:10.1063/1.4822961 · Cited by 11,670
X-ray diffraction procedures for polycrystalline and amorphous materials
Klug, H. P., & Alexander, L. (1954) · Cited by 6,000
Cited by
GSAS-II: the genesis of a modern open-source all purpose crystallography software package
Toby, B. H., & Von Dreele, R. B. (2013) · Journal of Applied Crystallography · doi:10.1107/s0021889813003531 · Cited by 6,195
Rietveld refinement guidelines
McCusker, L. B., Von Dreele, R. B., Cox, D. E., Louër, D., & Scardi, P. (1999) · Journal of Applied Crystallography · doi:10.1107/s0021889898009856 · Cited by 2,361
Self-citationNoheda, B., Gonzalo, J. A., Cross, L. E., Guo, R., Park, S.-E., Cox, D. E., & Shirane, G. (2000) · Physical Review B · doi:10.1103/physrevb.61.8687 · Cited by 879
Self-citationPhase diagram of the ferroelectric relaxor(1−x)PbMg1/3Nb2/3O3−xPbTiO3
Noheda, B., Cox, D. E., Shirane, G., Gao, J., & Ye, Z.-G. (2002) · Physical Review B · doi:10.1103/physrevb.66.054104 · Cited by 851
Self-citationStability of the monoclinic phase in the ferroelectric perovskitePbZr1−xTixO3
Noheda, B., Cox, D. E., Shirane, G., Guo, R., Jones, B., & Cross, L. E. (2000) · Physical Review B · doi:10.1103/physrevb.63.014103 · Cited by 588
Self-citationRietveld analysis software for J-PARC
Oishi, R., Yonemura, M., Nishimaki, Y., Torii, S., Hoshikawa, A., Ishigaki, T., Morishima, T., Mori, K., & Kamiyama, T. (2009) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/j.nima.2008.11.056 · Cited by 569
Size–strain line-broadening analysis of the ceria round-robin sample
Balzar, D., Audebrand, N., Daymond, M. R., Fitch, A., Hewat, A., Langford, J. I., Le Bail, A., Louër, D., Masson, O., McCowan, C. N., et al. (2004) · Journal of Applied Crystallography · doi:10.1107/s0021889804022551 · Cited by 537
Beauvais, L. G., Shores, M. P., & Long, J. R. (2000) · Journal of the American Chemical Society · doi:10.1021/ja994186h · Cited by 501
Neutron and x-ray diffraction studies of liquids and glasses
Fischer, H. E., Barnes, A. C., & Salmon, P. S. (2006) · Reports on Progress in Physics · doi:10.1088/0034-4885/69/1/r05 · Cited by 486
Microstructures and Spectroscopic Properties of Cryptomelane-type Manganese Dioxide Nanofibers
Gao, T., Glerup, M., Krumeich, F., Nesper, R., Fjellvåg, H., & Norby, P. (2008) · The Journal of Physical Chemistry C · doi:10.1021/jp804924f · Cited by 473
Rietveld quantitative amorphous content analysis
De La Torre, A. G., Bruque, S., & Aranda, M. A. G. (2001) · Journal of Applied Crystallography · doi:10.1107/s0021889801002485 · Cited by 397
Cava, S., Tebcherani, S. M., Souza, I. A., Pianaro, S. A., Paskocimas, C. A., Longo, E., & Varela, J. A. (2007) · Materials Chemistry and Physics · doi:10.1016/j.matchemphys.2007.02.046 · Cited by 265
FERNANDEZJIMENEZ, A., DELATORRE, A., PALOMO, A., LOPEZOLMO, G., ALONSO, M., & ARANDA, M. (2006) · Fuel · doi:10.1016/j.fuel.2005.08.014 · Cited by 262
Moreira, M. L., Paris, E. C., do Nascimento, G. S., Longo, V. M., Sambrano, J. R., Mastelaro, V. R., Bernardi, M. I. B., Andrés, J., Varela, J. A., & Longo, E. (2009) · Acta Materialia · doi:10.1016/j.actamat.2009.07.019 · Cited by 258
Rietveld quantitative phase analysis of Yeelimite-containing cements
Álvarez-Pinazo, G., Cuesta, A., García-Maté, M., Santacruz, I., Losilla, E. R., la Torre, A. G. D., León-Reina, L., & Aranda, M. A. G. (2012) · Cement and Concrete Research · doi:10.1016/j.cemconres.2012.03.018 · Cited by 254
Covalent organic frameworks as efficient adsorbent for sulfamerazine removal from aqueous solution
Zhuang, S., Liu, Y., & Wang, J. (2020) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2019.121126 · Cited by 249
Bocher, L., Aguirre, M. H., Logvinovich, D., Shkabko, A., Robert, R., Trottmann, M., & Weidenkaff, A. (2008) · Inorganic Chemistry · doi:10.1021/ic800463s · Cited by 234
Steele, J. A., Solano, E., Hardy, D., Dayton, D., Ladd, D., White, K., Chen, P., Hou, J., Huang, H., Saha, R. A., et al. (2023) · Advanced Energy Materials · doi:10.1002/aenm.202300760 · Cited by 230
De La Torre, Á. G., Bruque, S., Campo, J., & Aranda, M. A. G. (2002) · Cement and Concrete Research · doi:10.1016/s0008-8846(02)00796-2 · Cited by 227
Fernández-Jiménez, A., de la Torre, A. G., Palomo, A., López-Olmo, G., Alonso, M. M., & Aranda, M. A. G. (2006) · Fuel · doi:10.1016/j.fuel.2006.04.006 · Cited by 221
“Rietveld refinement was used to analyse the powder patterns [10,11], applying GSAS software [12] with a pseudo-Voigt function [13] and including a correction for asymmetry due to axial divergence [14].”
MethodHydration studies of calcium sulfoaluminate cements blended with fly ash
García-Maté, M., De la Torre, A. G., León-Reina, L., Aranda, M. A. G., & Santacruz, I. (2013) · Cement and Concrete Research · doi:10.1016/j.cemconres.2013.07.010 · Cited by 218
Alonso, J. A., Martínez-Lope, M. J., Casais, M. T., Aranda, M. A. G., & Fernández-Díaz, M. T. (1999) · Journal of the American Chemical Society · doi:10.1021/ja984015x · Cited by 201
Synchrotron powder X-ray diffraction study of the structure and dehydration behavior of sepiolite
Post, J. E., Bish, D. L., & Heaney, P. J. (2007) · American Mineralogist · doi:10.2138/am.2007.2134 · Cited by 177
Development of ferroelectric order in relaxor(1−x)Pb(Mg1/3Nb2/3)O3–xPbTiO3(0<~x<~0.15)
Ye, Z.-G., Bing, Y., Gao, J., Bokov, A. A., Stephens, P., Noheda, B., & Shirane, G. (2003) · Physical Review B · doi:10.1103/physrevb.67.104104 · Cited by 172
Crystal structures of quinacridones
Paulus, E. F., Leusen, F. J. J., & Schmidt, M. U. (2007) · CrystEngComm · doi:10.1039/b613059c · Cited by 163
Properties of adsorbents used for bleaching of vegetable oils and animal fats
Kuuluvainen, V., Mäki‐Arvela, P., Rautio, A., Kordas, K., Roine, J., Aho, A., Toukoniitty, B., Österholm, H., Toivakka, M., & Murzin, D. Y. (2015) · Journal of Chemical Technology & Biotechnology · doi:10.1002/jctb.4621 · Cited by 21
X-ray Total Scattering Study of Phases Formed from Cement Phases Carbonation
Cuesta, A., De la Torre, A. G., & Aranda, M. A. G. (2021) · Minerals · doi:10.3390/min11050519 · Cited by 14
“A pseudo-Voigt peak shape function with the asymmetry correction included [42,43] was used.”
Method
Metadata
- Authors
- Finger, L. W., Cox, D. E., & Jephcoat, A. P.
- Venue
- Journal of Applied Crystallography
- Published
- 1994-12-01
- Volume
- 27
- Issue
- 6
- Pages
- 892-900
- ISSN
- 0021-8898 (ISSN-L)
- OpenAlex
- W2086510160
- Cited by
- 1,242
- References
- 2
- FWCI
- 2.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.