Nanoflow electrospinning serial femtosecond crystallography
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
An electrospun liquid microjet has been developed that delivers protein microcrystal suspensions at flow rates of 0.14–3.1 µl min−1 to perform serial femtosecond crystallography (SFX) studies with X-ray lasers. Thermolysin microcrystals flowed at 0.17 µl min−1 and diffracted to beyond 4 Å resolution, producing 14 000 indexable diffraction patterns, or four per second, from 140 µg of protein. Nanoflow electrospinning extends SFX to biological samples that necessitate minimal sample consumption.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Femtosecond X-ray protein nanocrystallography
Chapman, H. N., Fromme, P., Barty, A., White, T. A., Kirian, R. A., Aquila, A., Hunter, M. S., Schulz, J., DePonte, D. P., Weierstall, U., et al. (2011) · Nature · doi:10.1038/nature09750 · Cited by 2,086 · cited 3×
“SFX of photosystem I (PSI) using a GDVN consumed 5.1 ml of 1 mg ml 1 solution at 1 109 crystals ml 1 to produce 112 725 crystal diffraction patterns with 10 Bragg peaks (Chapman et al., 2011).”
BackgroundMethodInfluentialSelf-citationHenderson, R. (1995) · Quarterly Reviews of Biophysics · doi:10.1017/s003358350000305x · Cited by 1,194 · cited 1×
“However, damage owing to X-ray radiation limits the achievable resolution, especially for proteins containing redox-active (metal) cofactors (Henderson, 1995; Yano et al., 2005).”
BackgroundControlling the Fiber Diameter during Electrospinning
Fridrikh, S. V., Yu, J. H., Brenner, M. P., & Rutledge, G. C. (2003) · Physical Review Letters · doi:10.1103/physrevlett.90.144502 · Cited by 941 · cited 2×
“…system, instead of creating diverging droplet streams of protein crystals using an electrospray we apply a principle utilized in electrospinning (Fridrikh et al., 2003), in which the length of the microjet is extended and droplet formation is delayed by adding glycerol and/or polyethylene…”
BackgroundMethodHigh-Resolution Protein Structure Determination by Serial Femtosecond Crystallography
Boutet, S., Lomb, L., Williams, G. J., Barends, T. R. M., Aquila, A., Doak, R. B., Weierstall, U., DePonte, D. P., Steinbrener, J., Shoeman, R. L., et al. (2012) · Science · doi:10.1126/science.1217737 · Cited by 857 · cited 2×
“SFX using the Coherent X-ray Imaging (CXI) endstation (Boutet & Williams, 2010) at the Linac Coherent Light Source (LCLS) has already produced high-resolution ( 2 Å) protein structures (Boutet et al., 2012).”
MethodSelf-citationYano, J., Kern, J., Irrgang, K.-D., Latimer, M. J., Bergmann, U., Glatzel, P., Pushkar, Y., Biesiadka, J., Loll, B., Sauer, K., et al. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0505207102 · Cited by 589 · cited 1×
“However, damage owing to X-ray radiation limits the achievable resolution, especially for proteins containing redox-active (metal) cofactors (Henderson, 1995; Yano et al., 2005).”
BackgroundSelf-citationGas dynamic virtual nozzle for generation of microscopic droplet streams
DePonte, D. P., Weierstall, U., Schmidt, K., Warner, J., Starodub, D., Spence, J. C. H., & Doak, R. B. (2008) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/41/19/195505 · Cited by 501
Self-citationSelf-terminating diffraction gates femtosecond X-ray nanocrystallography measurements
Barty, A., Caleman, C., Aquila, A., Timneanu, N., Lomb, L., White, T. A., Andreasson, J., Arnlund, D., Bajt, S., Barends, T. R. M., et al. (2012) · Nature Photonics · doi:10.1038/nphoton.2011.297 · Cited by 344
Self-citationTime-resolved protein nanocrystallography using an X-ray free-electron laser
Aquila, A., Hunter, M. S., Doak, R. B., Kirian, R. A., Fromme, P., White, T. A., Andreasson, J., Arnlund, D., Bajt, S., Barends, T. R. M., et al. (2012) · Optics Express · doi:10.1364/oe.20.002706 · Cited by 260 · cited 2×
“The GDVN is a highly successful tool for SFX experiments (Koopmann et al., 2012; Johansson et al., 2012; Boutet et al., 2012; Aquila et al., 2012; Lomb et al., 2011; Chapman et al., 2011; Barty et al., 2011; Weierstall et al., 2012).”
BackgroundMethodSelf-citationInjector for scattering measurements on fully solvated biospecies
Weierstall, U., Spence, J. C. H., & Doak, R. B. (2012) · Review of Scientific Instruments · doi:10.1063/1.3693040 · Cited by 225 · cited 2×
“Protein-crystal settling during sampleline transit or during storage in a reservoir reduces the acquisition rate of useful data in SFX by decreasing the crystal concentration in the X-ray-interaction region (Weierstall et al., 2012; Lomb et al., 2012).”
BackgroundMethodIn vivo protein crystallization opens new routes in structural biology
Koopmann, R., Cupelli, K., Redecke, L., Nass, K., DePonte, D. P., White, T. A., Stellato, F., Rehders, D., Liang, M., Andreasson, J., et al. (2012) · Nature Methods · doi:10.1038/nmeth.1859 · Cited by 212 · cited 1×
“The GDVN is a highly successful tool for SFX experiments (Koopmann et al., 2012; Johansson et al., 2012; Boutet et al., 2012; Aquila et al., 2012; Lomb et al., 2011; Chapman et al., 2011; Barty et al., 2011; Weierstall et al., 2012).”
MethodSelf-citation
Cited by
Linac Coherent Light Source: The first five years
Bostedt, C., Boutet, S., Fritz, D. M., Huang, Z., Lee, H. J., Lemke, H. T., Robert, A., Schlotter, W. F., Turner, J. J., & Williams, G. J. (2016) · Reviews of Modern Physics · doi:10.1103/revmodphys.88.015007 · Cited by 618
Self-citationSimultaneous Femtosecond X-ray Spectroscopy and Diffraction of Photosystem II at Room Temperature
Kern, J., Alonso-Mori, R., Tran, R., Hattne, J., Gildea, R. J., Echols, N., Glöckner, C., Hellmich, J., Laksmono, H., Sierra, R. G., et al. (2013) · Science · doi:10.1126/science.1234273 · Cited by 440
Self-citationStructure of photosystem II and substrate binding at room temperature
Young, I. D., Ibrahim, M., Chatterjee, R., Gul, S., Fuller, F. D., Koroidov, S., Brewster, A. S., Tran, R., Alonso-Mori, R., Kroll, T., et al. (2016) · Nature · doi:10.1038/nature20161 · Cited by 382
Self-citationSerial femtosecond crystallography: the first five years
Schlichting, I. (2015) · IUCrJ · doi:10.1107/s205225251402702x · Cited by 308
De novo protein crystal structure determination from X-ray free-electron laser data
Barends, T. R. M., Foucar, L., Botha, S., Doak, R. B., Shoeman, R. L., Nass, K., Koglin, J. E., Williams, G. J., Boutet, S., Messerschmidt, M., et al. (2014) · Nature · doi:10.1038/nature12773 · Cited by 266
Self-citationShort-wavelength free-electron laser sources and science: a review
Seddon, E. A., Clarke, J. A., Dunning, D. J., Masciovecchio, C., Milne, C. J., Parmigiani, F., Rugg, D., Spence, J. C. H., Thompson, N. R., Ueda, K., et al. (2017) · Reports on Progress in Physics · doi:10.1088/1361-6633/aa7cca · Cited by 252
Kern, J., Tran, R., Alonso-Mori, R., Koroidov, S., Echols, N., Hattne, J., Ibrahim, M., Gul, S., Laksmono, H., Sierra, R. G., et al. (2014) · Nature Communications · doi:10.1038/ncomms5371 · Cited by 233
Self-citationBotha, S., Nass, K., Barends, T. R. M., Kabsch, W., Latz, B., Dworkowski, F., Foucar, L., Panepucci, E., Wang, M., Shoeman, R. L., et al. (2015) · Acta Crystallographica Section D Biological Crystallography · doi:10.1107/s1399004714026327 · Cited by 215
“…crystallography (SFX) at X-ray FELs allows the acquisition of high-resolution undamaged snapshot diffraction patterns at ambient temperature (Chapman et al., 2011; Boutet et al., 2012) by constantly supplying fresh crystals in a liquid microjet (Weierstall et al., 2012, 2014; Sierra et al., 2012).”
BackgroundImaging live cell in micro-liquid enclosure by X-ray laser diffraction
Kimura, T., Joti, Y., Shibuya, A., Song, C., Kim, S., Tono, K., Yabashi, M., Tamakoshi, M., Moriya, T., Oshima, T., et al. (2014) · Nature Communications · doi:10.1038/ncomms4052 · Cited by 208
Drop-on-demand sample delivery for studying biocatalysts in action at X-ray free-electron lasers
Fuller, F. D., Gul, S., Chatterjee, R., Burgie, E. S., Young, I. D., Lebrette, H., Srinivas, V., Brewster, A. S., Michels-Clark, T., Clinger, J. A., et al. (2017) · Nature Methods · doi:10.1038/nmeth.4195 · Cited by 207
Self-citationFixed-target protein serial microcrystallography with an x-ray free electron laser
Hunter, M. S., Segelke, B., Messerschmidt, M., Williams, G. J., Zatsepin, N. A., Barty, A., Benner, W. H., Carlson, D. B., Coleman, M., Graf, A., et al. (2014) · Scientific Reports · doi:10.1038/srep06026 · Cited by 206
Self-citationThe Coherent X-ray Imaging instrument at the Linac Coherent Light Source
Liang, M., Williams, G. J., Messerschmidt, M., Seibert, M. M., Montanez, P. A., Hayes, M., Milathianaki, D., Aquila, A., Hunter, M. S., Koglin, J. E., et al. (2015) · Journal of Synchrotron Radiation · doi:10.1107/s160057751500449x · Cited by 171
“Other slower flowing jets such as an electrospinning source (Sierra et al., 2012), a lipidic cubic phase jet (Weierstall et al., 2014) as well as other high-viscosity carrier media (Botha et al., 2015) are all used to form flowing columns of sample at various speeds.”
BackgroundSelf-citationAtomic-resolution structures from fragmented protein crystals with the cryoEM method MicroED
de la Cruz, M. J., Hattne, J., Shi, D., Seidler, P., Rodriguez, J., Reyes, F. E., Sawaya, M. R., Cascio, D., Weiss, S. C., Kim, S. K., et al. (2017) · Nature Methods · doi:10.1038/nmeth.4178 · Cited by 158
Self-citationGoniometer-based femtosecond crystallography with X-ray free electron lasers
Cohen, A. E., Soltis, S. M., González, A., Aguila, L., Alonso-Mori, R., Barnes, C. O., Baxter, E. L., Brehmer, W., Brewster, A. S., Brunger, A. T., et al. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1418733111 · Cited by 144
Self-citationWatching proteins function with time-resolved x-ray crystallography
Šrajer, V., & Schmidt, M. (2017) · Journal of Physics D: Applied Physics · doi:10.1088/1361-6463/aa7d32 · Cited by 67
Metadata
- Authors
- Sierra, R. G., Laksmono, H., Kern, J., Tran, R., Hattne, J., Alonso-Mori, R., Lassalle-Kaiser, B., Glöckner, C., Hellmich, J., Schafer, D. W., Echols, N., Gildea, R. J., Grosse-Kunstleve, R. W., Sellberg, J., McQueen, T. A., Fry, A. R., Messerschmidt, M. M., Miahnahri, A., Seibert, M. M., Hampton, C. Y., Starodub, D., Loh, N. D., Sokaras, D., Weng, T.-C., Zwart, P. H., Glatzel, P., Milathianaki, D., White, W. E., Adams, P. D., Williams, G. J., Boutet, S., Zouni, A., Messinger, J., Sauter, N. K., Bergmann, U., Yano, J., Yachandra, V. K., & Bogan, M. J.
- Venue
- Acta Crystallographica Section D Biological Crystallography
- Published
- 2012-10-18
- Volume
- 68
- Issue
- 11
- Pages
- 1584-1587
- ISSN
- 0907-4449 (ISSN-L)
- OpenAlex
- W2119477002
- Cited by
- 187
- References
- 21
- FWCI
- 8.25
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.