CoChat

Lower extremity angle measurement with accelerometers-error and sensitivity analysis

Open access
Willemsen, A.T.M., Frigo, C., Boom, H.B.K. · 1991 · IEEE Transactions on Biomedical Engineering
Cited by 92

The DOI matches its Crossref record.

Abstract

Closed-loop control techniques for the restoration of locomotion of paraplegic subjects are expected to improve the quality of functional neuromuscular stimulation (FNS). We investigated the use of accelerometers for the assessment of feedback parameters. Previously, the possibility of angle assessment of the lower extremities using accelerometers, but without integration, was demonstrated. The current paper evaluates and assesses this method by an error and sensitivity analysis using healthy subject data. Of three potential error sources, the reference system, the accelerometers, and the model assumptions, the last was found to be the most important. Model calculations based on data obtained by the Elite video motion analysis system showed the rigid-body assumption error to be dominant for high frequencies (greater than 10 Hz), with vibrations in the order of 1 mm resulting in errors of one radial or more. For low frequencies (less than 5 Hz), the imperfect fixation of the accelerometers combined with a nonhinge type knee joint gave an error contribution of +/- 0.03 rad. The walking pattern was assumed to be two-dimensional which was shown to result in an error of +/- 0.04 rad. Accelerations due to rotations of the segments could be neglected. The total error computed for low frequencies (+/- 0.07 rad) was comparable to the experimental difference between the current and the reference system.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/10.137284

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 92

Metadata

Authors
Willemsen, A. T. M., Frigo, C., & Boom, H. B. K.
Venue
IEEE Transactions on Biomedical Engineering
Published
1991
Volume
38
Issue
12
Pages
1186-1193
ISSN
0018-9294 (ISSN-L)
OpenAlex
W2096680411
Cited by
92
References
0
FWCI
0.85
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Lower extremity angle measurement with accelerometers-error and sensitivity analysis. https://app.cochat.ai/papers/10.1109/10.137284
The paper
Willemsen, A. T. M., Frigo, C., & Boom, H. B. K. (1991). Lower extremity angle measurement with accelerometers-error and sensitivity analysis. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/10.137284

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.