Lower extremity angle measurement with accelerometers-error and sensitivity analysis
Open accessThe DOI matches its Crossref record.
Abstract
Closed-loop control techniques for the restoration of locomotion of paraplegic subjects are expected to improve the quality of functional neuromuscular stimulation (FNS). We investigated the use of accelerometers for the assessment of feedback parameters. Previously, the possibility of angle assessment of the lower extremities using accelerometers, but without integration, was demonstrated. The current paper evaluates and assesses this method by an error and sensitivity analysis using healthy subject data. Of three potential error sources, the reference system, the accelerometers, and the model assumptions, the last was found to be the most important. Model calculations based on data obtained by the Elite video motion analysis system showed the rigid-body assumption error to be dominant for high frequencies (greater than 10 Hz), with vibrations in the order of 1 mm resulting in errors of one radial or more. For low frequencies (less than 5 Hz), the imperfect fixation of the accelerometers combined with a nonhinge type knee joint gave an error contribution of +/- 0.03 rad. The walking pattern was assumed to be two-dimensional which was shown to result in an error of +/- 0.04 rad. Accelerations due to rotations of the segments could be neglected. The total error computed for low frequencies (+/- 0.07 rad) was comparable to the experimental difference between the current and the reference system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Gait Analysis Using Wearable Sensors
Tao, W., Liu, T., Zheng, R., & Feng, H. (2012) · Sensors · doi:10.3390/s120202255 · Cited by 1,165
Mayagoitia, R. E., Nene, A. V., & Veltink, P. H. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00231-7 · Cited by 655
Assessment of Walking Features From Foot Inertial Sensing
Sabatini, A. M., Martelloni, C., Scapellato, S., & Cavallo, F. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.840727 · Cited by 650
Shull, P. B., Jirattigalachote, W., Hunt, M. A., Cutkosky, M. R., & Delp, S. L. (2014) · Gait & Posture · doi:10.1016/j.gaitpost.2014.03.189 · Cited by 388
Methods for gait event detection and analysis in ambulatory systems
Rueterbories, J., Spaich, E. G., Larsen, B., & Andersen, O. K. (2010) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2010.03.007 · Cited by 350
Estimating Three-Dimensional Orientation of Human Body Parts by Inertial/Magnetic Sensing
Sabatini, A. M. (2011) · Sensors · doi:10.3390/s110201489 · Cited by 349
“These accelerometer-based angle sensors were discussed in [12], where the most important error sources were analyzed in detail, namely not fulfilling the gait motion planar model and the rigid-body condition by external fixation of body-mounted sensors.”
BackgroundFong, D. T.-P., & Chan, Y.-Y. (2010) · Sensors · doi:10.3390/s101211556 · Cited by 286
A review of portable FES-based neural orthoses for the correction of drop foot
Lyons, G. M., Sinkjaer, T., Burridge, J. H., & Wilcox, D. J. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806832 · Cited by 277
Clinical Applications of Sensors for Human Posture and Movement Analysis: A Review
Wong, W. Y., Wong, M. S., & Lo, K. H. (2007) · Prosthetics & Orthotics International · doi:10.1080/03093640600983949 · Cited by 193
“Several locomotion studies have tried to use accelerometers to determine the stages of lower limb movement in gait analysis (Veltink and Franken 1996; Veltink et al. 1998; Willemsen et al. 1991).”
BackgroundDetecting absolute human knee angle and angular velocity using accelerometers and rate gyroscopes
Williamson, R., & Andrews, B. J. (2001) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345283 · Cited by 185
“(1999) continued the tradition of using accelerometery to detect motion (SMIDT et at., 1971; MORRIS, 1973; SMIDT et at., 1977; WILLEMSEN et at., 1991; HEYN et at., 1996).”
BackgroundJoint-Angle Measurement Using Accelerometers and Gyroscopes—A Survey
Cheng, P., & Oelmann, B. (2010) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2009.2024367 · Cited by 140
“This method is reported in [11] and [12] and requires two biaxial accelerometers on both Li and Li−1 to calculate the joint angle θi.”
MethodSignal Quality and Compactness of a Dual-Accelerometer System for Gyro-Free Human Motion Analysis
Villeneuve, E., Harwin, W., Holderbaum, W., Sherratt, R. S., & White, R. (2016) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2582262 · Cited by 20
Joint Angle Measurement Using Strategically Placed Accelerometers and Gyroscope
Vikas, V., & Crane, C. D. (2016) · Journal of Mechanisms and Robotics · doi:10.1115/1.4031299 · Cited by 15
Metadata
- Authors
- Willemsen, A. T. M., Frigo, C., & Boom, H. B. K.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1991
- Volume
- 38
- Issue
- 12
- Pages
- 1186-1193
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2096680411
- Cited by
- 92
- References
- 0
- FWCI
- 0.85
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.