Orderly stimulation of skeletal muscle motor units with tripolar nerve cuff electrode
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
An electrical nerve stimulation technique, using single tripolar electrode, was shown to be capable of recruiting motor units according to their size, while allowing simultaneous but independent control of firing rate in the active units. Test paradigms consisting of established fundamental physiological concepts of soleus-gastrocnemius architecture, motor units conduction velocity, firing rate behavior of motor units of different sizes, and their susceptibility to fatigue were employed to validate the technique and demonstrate its utility as a basic and applied research tool.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
FUNCTIONAL SIGNIFICANCE OF CELL SIZE IN SPINAL MOTONEURONS
Henneman, E., Somjen, G., & Carpenter, D. O. (1965) · Journal of Neurophysiology · doi:10.1152/jn.1965.28.3.560 · Cited by 2,294
PROPERTIES OF MOTOR UNITS IN A HOMOGENEOUS RED MUSCLE (SOLEUS) OF THE CAT
McPhedran, A. M., Wuerker, R. B., & Henneman, E. (1965) · Journal of Neurophysiology · doi:10.1152/jn.1965.28.1.71 · Cited by 323
Grimby, L., & Hannerz, J. (1977) · The Journal of Physiology · doi:10.1113/jphysiol.1977.sp011699 · Cited by 303
Cited by
Nerve conduction block utilising high-frequency alternating current
Kilgore, K. L., & Bhadra, N. (2004) · Medical & Biological Engineering & Computing · doi:10.1007/bf02344716 · Cited by 284
Selective stimulation of peripheral nerve fibers using dual intrafascicular electrodes
Yoshida, K., & Horch, K. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.243412 · Cited by 208
Horch, K., Meek, S., Taylor, T. G., & Hutchinson, D. T. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2162635 · Cited by 194
“Some investigators have had some success in eliciting more effective topographical and axonal size recruitment selectivity with cuff electrodes, but in general these techniques are awkward, require larger currents, and are limited in their effectiveness [26]–[28].”
BackgroundYoshida, K., & Horch, K. (1993) · Annals of Biomedical Engineering · doi:10.1007/bf02368649 · Cited by 69
Endoneural selective stimulating using wire-microelectrode arrays
Smit, J. P. A., Rutten, W. L. C., & Boom, H. B. K. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.808943 · Cited by 20
Metadata
- Authors
- Baratta, R., Ichie, M., Hwang, S. K., & Solomonow, M.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1989
- Volume
- 36
- Issue
- 8
- Pages
- 836-843
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2157546960
- Cited by
- 118
- References
- 3
- FWCI
- 0.93
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Orderly stimulation of skeletal muscle motor units with tripolar nerve cuff electrode. https://app.cochat.ai/papers/10.1109/10.30809
- The paper
- Baratta, R., Ichie, M., Hwang, S. K., & Solomonow, M. (1989). Orderly stimulation of skeletal muscle motor units with tripolar nerve cuff electrode. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/10.30809
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.