Development of percutaneous intramuscular electrode for multichannel FES system
The DOI matches its Crossref record.
Abstract
A percutaneous intramuscular electrode was developed for controlling paralyzed extremities by FES. The electrode was made of a Teflon-coated 19 strand rope wound from ultrafine SUS 316L stainless steel wires and was helically coiled for giving high flexibility. Because of low percentages of electrode failure in the body, stable and reliable FES was achieved for a long time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 17
- handa, 1987, EMG-based stimulation patterns of FES for the paralyzed upper extremities, Proc 9th Int Symp ECHE, 329
- 10.1007/978-94-009-3361-3_6 · DOI
- 10.1109/10.32108 · DOI · Paper page
- handa, 1987, Percutaneous electrode for restoration of upper extremity function by FES, IEEE/9th Ann Conf EMBS, 1374
- handa, 1986, Studies on percutaneous wire electrode for FNS, IECE Japan
- marsolais, 1986, Implantation techniques and experience with percutaneous intramuscular electrodes in the lower extremities, J Rehab Res Develop, 23, 1
- peckham, 1987, Intramuscular electrode for neuromuscular stimulation, IEEE/9th Ann Conf EMBS, 1569
- bibel, 1987, Artificial nerves designed with ultrafine stranded wire, Wire J Intern, 32
- 10.1007/BF02363440 · DOI
- schwanda, 1983, Requirements for the first implantation of a 16-channel stimulation device in humans, Prog Artific Org, 2, 942
- nathan, 1984, The development of a computerized upper limb electrical stimulation system, Der Orthop�de, 7, 1170
- 10.1016/S0363-5023(80)80076-1 · DOI · Paper page
- handa, 1984, Electrically induced hand movements and their application for daily living, Proc 7th Int Symp ECHE, 169
- 10.1109/TBME.1987.325979 · DOI · Paper page
- marsolais, 1987, Functional electrical stimulation for walking in paraplegia, J Bone Joint Surg, 69 a, 729
- 10.1097/00003086-198305000-00005 · DOI · Paper page
- handa, 1985, A voice-controlled functional electrical stimulation system for the paralyzed hand, Japan J MEBE, 23, 292
Cited by
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845
Neuromuscular electrical stimulation in neurorehabilitation
Sheffler, L. R., & Chae, J. (2007) · Muscle & Nerve · doi:10.1002/mus.20758 · Cited by 529
(2001) · PubMed · Cited by 28
Some aspects of functional neuromuscular stimulation
Devasahayam, S. R. (1992) · Bioelectrochemistry and Bioenergetics · doi:10.1016/0302-4598(92)87036-t · Cited by 1
Metadata
- Authors
- Handa, Y., Hoshimiya, N., Iguchi, Y., & Oda, T.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1989-07
- Volume
- 36
- Issue
- 7
- Pages
- 705-710
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2112212331
- Cited by
- 98
- References
- 0
- FWCI
- 1.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.