The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
An Externally Powered, Multichannel, Implantable Stimulator for Versatile Control of Paralyzed Muscle
Abstract
Through the use of semicustom integrated circuit technology, an implantable muscle stimulator has been developed. The unit is small, lightweight, has low power consumption, and is intended for permanent usage. The stimulator circuitry is externally controlled and powered by a single encoded radio frequency carrier. Up to eight independently controlled stimulus output channels are provided, with output channel selection, stimulus pulse width, and stimulus pulse frequency under external control. A constant current biphasic stimulus pulse is used, in which the stimulus current amplitude can be preset by a single resistor value. The stimulator circuitry has been implemented in thick film hybrid form, and has undergone laboratory evaluation for 48 months.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Analysis and Design of Analog Integrated Circuits
Betts, W. R. (1978) · Electronics and Power · doi:10.1049/ep.1978.0296 · Cited by 3,827
Design of radio-frequency powered coils for implant instruments
Ko, W. H., Liang, S. P., & Fung, C. D. F. (1977) · Medical & Biological Engineering & Computing · doi:10.1007/bf02457921 · Cited by 374
Electrical Stimulation of the Brain
MCCRUM, W. R. (1962) · American Journal of Psychiatry · doi:10.1176/ajp.119.4.389-a · Cited by 311
Peckham, P. H., Marsolais, E. B., & Mortimer, J. T. (1980) · The Journal of Hand Surgery · doi:10.1016/s0363-5023(80)80076-1 · Cited by 166
Self-citationPeckham, P. H., Mortimer, J. T., & Marsolais, E. B. (1980) · Annals of Biomedical Engineering · doi:10.1007/bf02363440 · Cited by 145
Self-citationRecruitment properties of monopolar and bipolar epimysial electrodes
Grandjean, P. A., & Mortimer, J. T. (1986) · Annals of Biomedical Engineering · doi:10.1007/bf02364648 · Cited by 134
Closed-Loop Control of Force During Electrical Stimulation of Muscle
Crago, P. E., Mortimer, J. T., & Peckham, P. H. (1980) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1980.326738 · Cited by 134
Self-citationIntramuscular electrical stimulation: Tissue damage
Mortimer, J. T., Kaufman, D., & Roessmann, U. (1980) · Annals of Biomedical Engineering · doi:10.1007/bf02364479 · Cited by 123
Multichannel Implantable Stimulator for Control of Paralyzed Muscle
Peckham, P. H., Cw, P., Ko, W. H., Marsolais, E. B., & Rosen, J. J. (1981) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1981.324740 · Cited by 37
Self-citationThrope, G. B., Peckham, P. H., & Crago, P. E. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325461 · Cited by 36
Self-citation
Cited by
Functional Electrical Stimulation for Neuromuscular Applications
Peckham, P. H., & Knutson, J. S. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140103 · Cited by 784
Self-citationWireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656
Neuromuscular electrical stimulation in neurorehabilitation
Sheffler, L. R., & Chae, J. (2007) · Muscle & Nerve · doi:10.1002/mus.20758 · Cited by 529
Weiland, J. D., Liu, W., & Humayun, M. S. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.060804.100435 · Cited by 371
Peckham, P. H., Keith, M. W., Kilgore, K. L., Grill, J. H., Wuolle, K. S., Thrope, G. B., Gorman, P., Hobby, J., Mulcahey, M. J., Carroll, S., et al. (2001) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.25910 · Cited by 319
Self-citation
Metadata
- Authors
- Smith, B., Peckham, P. H., Keith, M. W., & Roscoe, D. D.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1987-07
- Volume
- BME-34
- Issue
- 7
- Pages
- 499-508
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W1967848970
- Cited by
- 281
- References
- 10
- FWCI
- 2.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An Externally Powered, Multichannel, Implantable Stimulator for Versatile Control of Paralyzed Muscle. https://app.cochat.ai/papers/10.1109/tbme.1987.325979
- The paper
- Smith, B., Peckham, P. H., Keith, M. W., & Roscoe, D. D. (1987). An Externally Powered, Multichannel, Implantable Stimulator for Versatile Control of Paralyzed Muscle. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.1987.325979
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.