Evaluation of shoulder movement as a command control source
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The purpose of this study was to evaluate the use of scapular shoulder movement as a command control source. The focus of this study was on the evaluation of movement signals from quadriplegic subjects as well as on the processing of these signals for use as command inputs to a functional neuromuscular stimulation (FNS) hand-grasp system. The shoulder movement of three C5-level quadriplegic and nine normal subjects was studied using externally mounted two-degree-of-freedom transducers overlying the sternum and clavicles. The C5-level quadriplegic subjects tested had a considerably poorer range of motion than the normal subjects. The range of motion was greatest in elevation but was coupled with a significant component of retraction. The vertical command resolution of the quadriplegic subjects ranged from eight to 13 command levels, whereas the horizontal range contained four or fewer command levels. Normal subjects were able to produce 26 to 79 command levels along the vertical axis and 18 to 85 along the horizontal axis. Subjects were able to maintain a static command level to within several percent of their range in trials lasting from 10 to 30 s. The quadriplegic subjects performed poorly in tasks where they were required to move to a point along the horizontal or vertical central axis and then along the opposite axis. The normal subjects were readily able to perform these tasks. The interference with the command signal due to movement of the opposite extremity was significant, with a maximum error ranging between 25 and 86% along the vertical axis and between 38 and 105% along the horizontal axis. Rise time and normalized velocity (velocity divided by the size of the movement) were found to be suitable for distinguishing different types of shoulder movements independent of the size of the movement. Shoulder movement in quadriplegics is suitable as a command control source for a FNS hand-grasp system requiring one proportional command signal and at least one logical command signal with appropriate processing of the signals. The available transducers are cosmetically acceptable and are easy to don and doff. Use of shoulder movement as a command control source does not interfere with other activities of the user such as eating or talking. Shoulder movement also provides a command control source that is easy for the user to learn and provides some feedback to the user through shoulder proprioception.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hogan, N., & Mann, R. W. (1980) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1980.326653 · Cited by 126
Cited by
Neuromuscular electrical stimulation in neurorehabilitation
Sheffler, L. R., & Chae, J. (2007) · Muscle & Nerve · doi:10.1002/mus.20758 · Cited by 529
Peckham, P. H., Keith, M. W., Kilgore, K. L., Grill, J. H., Wuolle, K. S., Thrope, G. B., Gorman, P., Hobby, J., Mulcahey, M. J., Carroll, S., et al. (2001) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.25910 · Cited by 319
Self-citationAn Implanted Upper-Extremity Neuroprosthesis. Follow-up of Five Patients*
KILGORE, K. L., PECKHAM, P. H., KEITH, M. W., THROPE, G. B., WUOLLE, K. S., BRYDEN, A. M., & HART, R. L. (1997) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199704000-00008 · Cited by 192
Self-citationHarrington, S., Padua, D., Battaglini, C., Michener, L. A., Giuliani, C., Myers, J., & Groff, D. (2011) · Journal of Cancer Survivorship · doi:10.1007/s11764-010-0168-0 · Cited by 159
Implanted stimulators for restoration of function in spinal cord injury
Bhadra, N., Kilgore, K. L., & Peckham, P. H. (2001) · Medical Engineering & Physics · doi:10.1016/s1350-4533(01)00012-1 · Cited by 92
“The implanted joint angle transducer (IJAT) senses joint angle in two degrees of freedom for use as an implanted command-control source [33], replacing the external shoulder position transducer [34] of the Freehand System (Fig.”
MethodSelf-citation
Metadata
- Authors
- Johnson, M. W., & Peckham, P. H.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1990
- Volume
- 37
- Issue
- 9
- Pages
- 876-885
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2105855451
- Cited by
- 74
- References
- 1
- FWCI
- 2.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.