CoChat

Evaluation of shoulder movement as a command control source

Johnson, M.W., Peckham, P.H. · 1990 · IEEE Transactions on Biomedical Engineering
Cited by 74

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The purpose of this study was to evaluate the use of scapular shoulder movement as a command control source. The focus of this study was on the evaluation of movement signals from quadriplegic subjects as well as on the processing of these signals for use as command inputs to a functional neuromuscular stimulation (FNS) hand-grasp system. The shoulder movement of three C5-level quadriplegic and nine normal subjects was studied using externally mounted two-degree-of-freedom transducers overlying the sternum and clavicles. The C5-level quadriplegic subjects tested had a considerably poorer range of motion than the normal subjects. The range of motion was greatest in elevation but was coupled with a significant component of retraction. The vertical command resolution of the quadriplegic subjects ranged from eight to 13 command levels, whereas the horizontal range contained four or fewer command levels. Normal subjects were able to produce 26 to 79 command levels along the vertical axis and 18 to 85 along the horizontal axis. Subjects were able to maintain a static command level to within several percent of their range in trials lasting from 10 to 30 s. The quadriplegic subjects performed poorly in tasks where they were required to move to a point along the horizontal or vertical central axis and then along the opposite axis. The normal subjects were readily able to perform these tasks. The interference with the command signal due to movement of the opposite extremity was significant, with a maximum error ranging between 25 and 86% along the vertical axis and between 38 and 105% along the horizontal axis. Rise time and normalized velocity (velocity divided by the size of the movement) were found to be suitable for distinguishing different types of shoulder movements independent of the size of the movement. Shoulder movement in quadriplegics is suitable as a command control source for a FNS hand-grasp system requiring one proportional command signal and at least one logical command signal with appropriate processing of the signals. The available transducers are cosmetically acceptable and are easy to don and doff. Use of shoulder movement as a command control source does not interfere with other activities of the user such as eating or talking. Shoulder movement also provides a command control source that is easy for the user to learn and provides some feedback to the user through shoulder proprioception.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/10.58598

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Johnson, M. W., & Peckham, P. H.
Venue
IEEE Transactions on Biomedical Engineering
Published
1990
Volume
37
Issue
9
Pages
876-885
ISSN
0018-9294 (ISSN-L)
OpenAlex
W2105855451
Cited by
74
References
1
FWCI
2.78
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.