The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A multichannel neural probe for selective chemical delivery at the cellular level
Abstract
A bulk-micromachined multichannel silicon probe capable of selectively delivering chemicals at the cellular level as well as electrically recording from and stimulating neurons in vivo has been developed. The process buries multiple flow channels in the probe substrate, resulting in a hollow-core device. Microchannel formation requires only one mask in addition to those normally used for probe fabrication and is compatible with on-chip signal-processing circuitry. Flow in these microchannels has been studied theoretically and experimentally. For an effective channel diameter of 10 microns, a channel length of 4 mm, and water as the injected fluid, the flow velocity at 11 torr is about 1.3 mm/s, delivering 100 pl in 1 s. Intermixing of chemicals with the tissue fluid due to natural diffusion through the outlet orifice becomes significant for dwell times in excess of about 30 min, and a shutter is proposed for chronic use. The probe has been used for acute monitoring of the neural responses to various chemical stimuli in guinea pig superior and inferior colliculus.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gamma (40-100 Hz) oscillation in the hippocampus of the behaving rat
Bragin, A., Jando, G., Nadasdy, Z., Hetke, J., Wise, K., & Buzsaki, G. (1995) · The Journal of Neuroscience · doi:10.1523/jneurosci.15-01-00047.1995 · Cited by 1,527
Self-citation
Cited by
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
McAllister, D. V., Wang, P. M., Davis, S. P., Park, J.-H., Canatella, P. J., Allen, M. G., & Prausnitz, M. R. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2331316100 · Cited by 859
Wireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656
Self-citationAldawood, F. K., Andar, A., & Desai, S. (2021) · Polymers · doi:10.3390/polym13162815 · Cited by 499
Silicon micromachined hollow microneedles for transdermal liquid transport
Gardeniers, H. J. G. E., Luttge, R., Berenschot, E. J. W., de Boer, M. J., Yeshurun, S. Y., Hefetz, M., van-t Oever, R., & van den Berg, A. (2003) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2003.820293 · Cited by 413
Metadata
- Authors
- Chen, J., Wise, K. D., Hetke, J. F., & Bledsoe, S. C.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1997
- Volume
- 44
- Issue
- 8
- Pages
- 760-769
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2111380284
- Cited by
- 280
- References
- 1
- FWCI
- 1.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A multichannel neural probe for selective chemical delivery at the cellular level. https://app.cochat.ai/papers/10.1109/10.605435
- The paper
- Chen, J., Wise, K. D., Hetke, J. F., & Bledsoe, S. C. (1997). A multichannel neural probe for selective chemical delivery at the cellular level. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/10.605435
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.