The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
A multichannel neural probe for selective chemical delivery at the cellular level
Abstract
A bulk-micromachined multichannel silicon probe capable of selectively delivering chemicals at the cellular level as well as electrically recording from and stimulating neurons in vivo has been developed. The process buries multiple flow channels in the probe substrate, resulting in a hollow-core device. Microchannel formation requires only one mask in addition to those normally used for probe fabrication and is compatible with on-chip signal-processing circuitry. Flow in these microchannels has been studied theoretically and experimentally. For an effective channel diameter of 10 microns, a channel length of 4 mm, and water as the injected fluid, the flow velocity at 11 torr is about 1.3 mm/s, delivering 100 pl in 1 s. Intermixing of chemicals with the tissue fluid due to natural diffusion through the outlet orifice becomes significant for dwell times in excess of about 30 min, and a shutter is proposed for chronic use. The probe has been used for acute monitoring of the neural responses to various chemical stimuli in guinea pig superior and inferior colliculus.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Seidel, H., Csepregi, L., Heuberger, A., & Baumgärtel, H. (1990) · Journal of The Electrochemical Society · doi:10.1149/1.2086277 · Cited by 1,633
Gamma (40-100 Hz) oscillation in the hippocampus of the behaving rat
Bragin, A., Jando, G., Nadasdy, Z., Hetke, J., Wise, K., & Buzsaki, G. (1995) · The Journal of Neuroscience · doi:10.1523/jneurosci.15-01-00047.1995 · Cited by 1,527
Self-citationDrake, K. L., Wise, K. D., Farraye, J., Anderson, D. J., & BeMent, S. L. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.7273 · Cited by 362
Self-citationLiquid transport in micron and submicron channels
Pfahler, J., Harley, J., Bau, H., & Zemel, J. (1990) · Sensors and Actuators A: Physical · doi:10.1016/0924-4247(89)80008-1 · Cited by 327
Fabrication of novel three-dimensional microstructures by the anisotropic etching of
Bassous, E. (1978) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1978.19249 · Cited by 309
A high-yield IC-compatible multichannel recording array
Najafi, K., Wise, K. D., & Mochizuki, T. (1985) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1985.22102 · Cited by 301
Self-citationThe history and development of microiontophoresis in experimental neurobiology
Hicks, T. P. (1984) · Progress in Neurobiology · doi:10.1016/0301-0082(84)90019-4 · Cited by 82
Characterization of drug iontophoresis with a fast microassay technique
Dionne, V. E. (1976) · Biophysical Journal · doi:10.1016/s0006-3495(76)85723-2 · Cited by 66
Multiple single-unit recordings from the CNS using thin-film electrode arrays
Carter, R. R., & Houk, J. C. (1993) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.279266 · Cited by 39
A technique for microiontophoretic study of single neurons in the freely moving rat
West, M. O., & Woodward, D. J. (1984) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(84)90036-0 · Cited by 36
Cited by
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
Microneedles for transdermal drug delivery
Prausnitz, M. R. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2003.10.023 · Cited by 1,521
Davis, S. P., Landis, B. J., Adams, Z. H., Allen, M. G., & Prausnitz, M. R. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.12.010 · Cited by 934
McAllister, D. V., Wang, P. M., Davis, S. P., Park, J.-H., Canatella, P. J., Allen, M. G., & Prausnitz, M. R. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2331316100 · Cited by 859
Microfluidic devices for cellomics: a review
Andersson, H., & van den Berg, A. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(03)00266-1 · Cited by 661
Metadata
- Authors
- Chen, J., Wise, K. D., Hetke, J. F., & Bledsoe, S. C.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1997
- Volume
- 44
- Issue
- 8
- Pages
- 760-769
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2111380284
- Cited by
- 280
- References
- 10
- FWCI
- 1.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.