An advanced demultiplexing system for physiological stimulation
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
A CMOS very large scale integration (VLSI) chip has been designed and built to implement a scheme developed for multiplexing/demultiplexing the signals required to operate an intracortical stimulating electrode array. Because the use of radio telemetry in a proposed system utilizing this chip may impose limits upon the rate of data transmission to the chip, the scheme described herein was used to reduce the amount of digital information which must be sent to control a large quantity (up to several hundred) of stimulating electrodes. By incorporating multiple current sources on chip, many channels may be stimulated simultaneously. By incorporating on-chip timers, control over pulse timing is assigned to the chip, reducing by up to fourfold the amount of control data which must be sent. By incorporating on-chip RAM, information associated with the desired stimulus amplitude and pulse timing can be stored on chip. In this manner, it is necessary to send control information to the chip only when the information changes, rather than at the stimulus repeat rate for each channel. This further reduces the data rate by a factor of five to ten times or more. The architecture described here, implemented as an eight-channel stimulator, is scalable to a 625-channel stimulator while keeping data transmission rates under 2 Mbps.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The sensations produced by electrical stimulation of the visual cortex
Brindley, G. S., & Lewin, W. S. (1968) · The Journal of Physiology · doi:10.1113/jphysiol.1968.sp008519 · Cited by 1,170 · cited 1×
“Each pulse in the train would have a total duration of 50‐500 s, and these pulses would be repeated at a rate of 20‐300 Hz. The brightness of the individual phosphene would be controlled via the current amplitude, the pulse width, the pulse repeat rate, or some combination of the three [9], [ 10 ].”
BackgroundCampbell, P. K., Jones, K. E., Huber, R. J., Horch, K. W., & Normann, R. A. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83588 · Cited by 881 · cited 1×
“PREVIOUSLY, we have described the manufacture of an intracortical electrode array [1], [2].”
MethodSelf-citationSchmidt, E. M., Bak, M. J., Hambrecht, F. T., Kufta, C. V., O'Rourke, D. K., & Vallabhanath, P. (1996) · Brain · doi:10.1093/brain/119.2.507 · Cited by 672 · cited 1×
“In such a system, stimulation of an individual electrode in the visual cortex of a blind individual would produce the perception of a point of light, or phosphene [6], [ 7 ].”
BackgroundDobelle, W. H., & Mladejovsky, M. G. (1974) · The Journal of Physiology · doi:10.1113/jphysiol.1974.sp010766 · Cited by 468
Visual sensations produced by intracortical microstimulation of the human occipital cortex
Bak, M., Girvin, J. P., Hambrecht, F. T., Kufta, C. V., Loeb, G. E., & Schmidt, E. M. (1990) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442682 · Cited by 299
Simulation of a phosphene-based visual field: Visual acuity in a pixelized vision system
Cha, K., Horch, K., & Normann, R. A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368135 · Cited by 198
Self-citation
Cited by
Retinal Prosthesis for the Blind
Margalit, E., Maia, M., Weiland, J. D., Greenberg, R. J., Fujii, G. Y., Torres, G., Piyathaisere, D. V., O'Hearn, T. M., Liu, W., Lazzi, G., et al. (2002) · Survey of Ophthalmology · doi:10.1016/s0039-6257(02)00311-9 · Cited by 427
A neural interface for a cortical vision prosthesis
Normann, R. A., Maynard, E. M., Rousche, P. J., & Warren, D. J. (1999) · Vision Research · doi:10.1016/s0042-6989(99)00040-1 · Cited by 409
Self-citationWeiland, J. D., Liu, W., & Humayun, M. S. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.060804.100435 · Cited by 371
A Wideband Frequency-Shift Keying Wireless Link for Inductively Powered Biomedical Implants
Ghovanloo, M., & Najafi, K. (2004) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2004.838144 · Cited by 290
Ghovanloo, M., & Najafi, K. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.839797 · Cited by 137
Metadata
- Authors
- Jones, K. E., & Normann, R. A.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1997
- Volume
- 44
- Issue
- 12
- Pages
- 1210-1220
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2095812246
- Cited by
- 60
- References
- 6
- FWCI
- 0.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.