The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
A semiclosed-loop algorithm for the control of blood glucose levels in diabetics
Abstract
In this paper, a theoretical analysis of the control of plasma glucose levels in diabetic individuals is undertaken using a simple mathematical model of the dynamics of glucose and insulin interaction in the blood system. Mathematical optimization techniques are applied to the mathematical model to derive insulin infusion programs for the control of blood levels in diabetic individuals. Based on the results of the mathematical optimization, a semiclosed-loop algorithm is proposed for continuous insulin delivery to diabetic patients. The algorithm is based on three hourly plasma glucose samples. A theoretical evaluation of the effectiveness of this algorithm shows that it is superior to two existing algorithms in controlling hyperglycemia. A glucose infusion term representing the effect of glucose intake resulting from a meal is then introduced into the model equations. Various insulin infusion programs for the control of plasma glucose levels following a meal are then assessed. The theoretical results suggest that the most effective short-term control is achieved by an insulin infusion program which incorporates an injection to coincide with the meal.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantitative estimation of insulin sensitivity.
Bergman, R. N., Ider, Y. Z., Bowden, C. R., & Cobelli, C. (1979) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1979.236.6.e667 · Cited by 1,874
Bergman, R. N., Phillips, L. S., & Cobelli, C. (1981) · Journal of Clinical Investigation · doi:10.1172/jci110398 · Cited by 1,640
Assessment of Insulin Sensitivity in Vivo*
Bergman, R. N., Finegood, D. T., & Ader, M. (1985) · Endocrine Reviews · doi:10.1210/edrv-6-1-45 · Cited by 1,066
Bergman, R. N., Prager, R., Volund, A., & Olefsky, J. M. (1987) · Journal of Clinical Investigation · doi:10.1172/jci112886 · Cited by 772
Continuous subcutaneous insulin infusion: an approach to achieving normoglycaemia.
Pickup, J. C., Keen, H., Parsons, J. A., & Alberti, K. G. (1978) · BMJ · doi:10.1136/bmj.1.6107.204 · Cited by 563
A threshold distribution hypothesis for packet storage of insulin and its mathematical modeling
Grodsky, G. M. (1972) · Journal of Clinical Investigation · doi:10.1172/jci107011 · Cited by 395
Principles of Optimal Control Theory
Gamkrelidze, R. V. (1978) · Springer eBooks · doi:10.1007/978-1-4684-7398-8 · Cited by 320
Pfeiffer, E., Thum, C., & Clemens, A. (1974) · Hormone and Metabolic Research · doi:10.1055/s-0028-1093841 · Cited by 238
Model studies of blood-glucose regulation
Ackerman, E., Gatewood, L. C., Rosevear, J. W., & Molnar, G. D. (1965) · The Bulletin of Mathematical Biophysics · doi:10.1007/bf02477259 · Cited by 210
Applications of Optimal Control Theory in Biomedicine
Swan, G. W. (1984) · Medical Entomology and Zoology · Cited by 135
Pickup, J. C., Shaw, G. W., & Claremont, D. J. (1989) · Diabetologia · doi:10.1007/bf00265097 · Cited by 114
Practical Closed-Loop Insulin Delivery
White, N. H., SKOR, D., & SANTIAGO, J. V. (1982) · Annals of Internal Medicine · doi:10.7326/0003-4819-97-2-210 · Cited by 110
Stable-Label Intravenous Glucose Tolerance Test Minimal Model
Avogaro, A., Bristow, J., Bier, D., Cobelli, C., & Toffolo, G. (1989) · Diabetes · doi:10.2337/diab.38.8.1048 · Cited by 107
Insulin responses to varying profiles of subcutaneous insulin infusion: kinetic modelling studies
Kraegen, E. W., & Chisholm, D. J. (1984) · Diabetologia · doi:10.1007/bf00252409 · Cited by 96
Optimal insulin infusion resulting from a mathematical model of blood glucose dynamics
Fisher, M. E., & Teo, K. L. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.18755 · Cited by 89
Self-citationApplication of optimal control theory to diabetes mellitus
Ollerton, R. (1989) · International Journal of Control · doi:10.1080/00207178908953512 · Cited by 89
Timing of Insulin Delivery with Meals
Kraegen, E. W., Chisholm, D. J., & McNamara, M. (1981) · Hormone and Metabolic Research · doi:10.1055/s-2007-1019271 · Cited by 88
Mirouze, J., Selam, J. L., Pham, T. C., & Cavadore, D. (1977) · Diabetologia · doi:10.1007/bf01219712 · Cited by 86
Control of Hyperglycemia in Adult Diabetics by Pulsed Insulin Delivery
GENUTH, S. M., & Martin, P. J. (1977) · Diabetes · doi:10.2337/diab.26.6.571 · Cited by 66
Marliss, E. B., Murray, F. T., Stokes, E. F., et al. (1977) · Diabetes · doi:10.2337/diab.26.7.663 · Cited by 65
Control of Blood Glucose in Diabetics using an Artificial Pancreas*
Kraegen, E. W., Campbell, L. V., Chia, Y. O., Meier, H., & Lazarus, L. (1977) · Australian and New Zealand Journal of Medicine · doi:10.1111/j.1445-5994.1977.tb03687.x · Cited by 57
Pfeiffer, E. F. (1987) · Diabetologia · doi:10.1007/bf00274572 · Cited by 45
Service, F. J. (1978) · PubMed · Cited by 28
Insulin treatment: A non-stop revolution
Mirouze, J. (1983) · Diabetologia · doi:10.1007/bf00279931 · Cited by 19
Cited by
In Silico Preclinical Trials: A Proof of Concept in Closed-Loop Control of Type 1 Diabetes
Kovatchev, B. P., Breton, M., Dalla Man, C., & Cobelli, C. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300106 · Cited by 760
A model-based algorithm for blood glucose control in Type I diabetic patients
Parker, R. S., Doyle, F. J., & Peppas, N. A. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.740877 · Cited by 500
A System Model of Oral Glucose Absorption: Validation on Gold Standard Data
Man, C. D., Camilleri, M., & Cobelli, C. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.883792 · Cited by 311
Metadata
- Authors
- Fisher, M. E.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1991
- Volume
- 38
- Issue
- 1
- Pages
- 57-61
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2122549537
- Cited by
- 271
- References
- 24
- FWCI
- 0.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.