Artifact reduction in magnetoneurography based on time-delayed second-order correlations
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Artifacts in magnetoneurography data due to endogenous biological noise sources, like the cardiac signal, can be four orders of magnitude higher than the signal of interest. Therefore, it is important to establish effective artifact reduction methods. We propose a blind source separation algorithm using only second-order temporal correlations for cleaning biomagnetic measurements of evoked responses in the peripheral nervous system. The algorithm showed its efficiency by eliminating disturbances originating from biological and technical noise sources and successfully extracting the signal of interest. This yields a significant improvement of the neuro-magnetic source analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Information-Maximization Approach to Blind Separation and Blind Deconvolution
Bell, A. J., & Sejnowski, T. J. (1995) · Neural Computation · doi:10.1162/neco.1995.7.6.1129 · Cited by 8,986
Multiple dipole modeling and localization from spatio-temporal MEG data
Mosher, J. C., Lewis, P. S., & Leahy, R. M. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.141192 · Cited by 1,048
Separation of a mixture of independent signals using time delayed correlations
Molgedey, L., & Schuster, H. G. (1994) · Physical Review Letters · doi:10.1103/physrevlett.72.3634 · Cited by 882 · cited 2×
“For two lagged correlation matrices and the optimization problem can be solved directly as the (nonsymmetric) eigenvalue problem [ 19 ]”
Method
Cited by
Nonlinear Component Analysis as a Kernel Eigenvalue Problem
Schölkopf, B., Smola, A., & Müller, K.-R. (1998) · Neural Computation · doi:10.1162/089976698300017467 · Cited by 8,084
Probabilistic Principal Component Analysis
Tipping, M. E., & Bishop, C. M. (1999) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/1467-9868.00196 · Cited by 3,679
Independent Component Analysis: Principles and Practice
(2001) · Cambridge University Press eBooks · doi:10.1017/cbo9780511624148 · Cited by 1,917
Single-trial analysis and classification of ERP components — A tutorial
Blankertz, B., Lemm, S., Treder, M., Haufe, S., & Müller, K.-R. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.06.048 · Cited by 1,138
Self-citationIndependent component approach to the analysis of EEG and MEG recordings
Vigario, R., Sarela, J., Jousmiki, V., Hamalainen, M., & Oja, E. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.841330 · Cited by 796
Introduction to machine learning for brain imaging
Lemm, S., Blankertz, B., Dickhaus, T., & Müller, K.-R. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.11.004 · Cited by 630
An approach to blind source separation based on temporal structure of speech signals
Murata, N., Ikeda, S., & Ziehe, A. (2001) · Neurocomputing · doi:10.1016/s0925-2312(00)00345-3 · Cited by 565
Self-citationRitter, P., Moosmann, M., & Villringer, A. (2009) · Human Brain Mapping · doi:10.1002/hbm.20585 · Cited by 400
TDSEP — an efficient algorithm for blind separation using time structure
Ziehe, A., & Müller, K.-R. (1998) · Perspectives in Neural Computing · doi:10.1007/978-1-4471-1599-1_103 · Cited by 334
Self-citationRobust artifactual independent component classification for BCI practitioners
Winkler, I., Brandl, S., Horn, F., Waldburger, E., Allefeld, C., & Tangermann, M. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/3/035013 · Cited by 327
Barbati, G., Porcaro, C., Zappasodi, F., Rossini, P. M., & Tecchio, F. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2003.12.015 · Cited by 293
Arnstein, D., Cui, F., Keysers, C., Maurits, N. M., & Gazzola, V. (2011) · The Journal of Neuroscience · doi:10.1523/jneurosci.0963-11.2011 · Cited by 245
“In EEGlab, an independent component analysis was performed using the TDsep (Ziehe et al., 2000) algorithm (http://sccn.ucsd.edu/eeglab/) and components visually identified as ocular artifacts or residual MRI artifacts were removed.”
MethodStone, J. V., Porrill, J., Porter, N. R., & Wilkinson, I. D. (2002) · NeuroImage · doi:10.1006/nimg.2001.0986 · Cited by 182
“It is possible that different results could have been obtained using second order blind source separation (BSS) methods (Ziehe et al., 2000; Stone, 2001), because such methods make minimal assumptions regarding the pdfs of data.”
MethodMagnetoneurography: theory and application to peripheral nerve disorders
Mackert, B.-M. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.07.028 · Cited by 36
Self-citation
Metadata
- Authors
- Ziehe, A., Muller, K.-R., Nolte, G., Mackert, B.-M., & Curio, G.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2000
- Volume
- 47
- Issue
- 1
- Pages
- 75-87
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2147955712
- Cited by
- 140
- References
- 3
- FWCI
- 20.35
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.