The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Chronic neural stimulation with thin-film, iridium oxide electrodes
Abstract
Experiments were conducted to assess the effect of chronic stimulation on the electrical properties of the electrode-tissue system, as measured using electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). Silicon, micromachined probes with multiple iridium oxide stimulating electrodes (400-1600 micron 2) were implanted in guinea pig cortex. A 10-17 day post-operative recovery period was followed by five days of monopolar stimulation, two hours/electrode each day using biphasic, constant current stimulation (5-100 microA, 100 microseconds/phase). EIS and CV data were taken before and after stimulation. The post-stimulation impedance [at mid-range frequencies (100 Hz-100 kHz)] consistently and significantly decreased relative to prestimulation levels. Impedance magnitude increased permanently at low frequencies (< 100 Hz), correlating to a change in the charge storage capacity (the area under a cyclic voltammagram). Impedance magnitude significantly increased during the recovery period, though this increase could be mostly reversed by applying small currents. A mathematical model of the electrode-tissue system impedance was used to analyze in vivo behavior. The data and modeling results shows that applying charge to the electrode can consistently reduce the impedance of the electrode-tissue system. Analysis of explanted probes suggests that the interaction between the tissue and electrode is dependent on whether chronic pulses were applied. It is hypothesized that the interface between the tissue and metal is altered by current pulsing, resulting in a temporary impedance shift.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transition from “Supercapacitor” to “Battery” Behavior in Electrochemical Energy Storage
Conway, B. E. (1991) · Journal of The Electrochemical Society · doi:10.1149/1.2085829 · Cited by 2,339
(1986) · Springer eBooks · doi:10.1007/978-3-642-71010-0 · Cited by 2,123
Impedance spectroscopy: Emphasizing solid materials and systems
Hollins, P. (1988) · Spectrochimica Acta Part A: Molecular Spectroscopy · doi:10.1016/0584-8539(88)80155-7 · Cited by 1,583
Charge density and charge per phase as cofactors in neural injury induced by electrical stimulation
McCreery, D. B., Agnew, W. F., Yuen, T. G. H., & Bullara, L. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.102812 · Cited by 708
Note on the parameterization of the constant-phase admittance element
ROSSMACDONALD, J. (1984) · Solid State Ionics · doi:10.1016/0167-2738(84)90049-3 · Cited by 549
The electrical properties of metal microelectrodes
Robinson, D. A. (1968) · Proceedings of the IEEE · doi:10.1109/proc.1968.6458 · Cited by 464
Electrical properties of implant encapsulation tissue
Grill, W. M., & Thomas Mortimer, J. (1994) · Annals of Biomedical Engineering · doi:10.1007/bf02368219 · Cited by 376
Batch fabricated thin-film electrodes for stimulation of the central auditory system
Anderson, D. J., Najafi, K., Tanghe, S. J., Evans, D. A., Levy, K. L., Hetke, J. F., Xue, X., Zappia, J. J., & Wise, K. D. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.32101 · Cited by 229
Self-citationActivated Ir: An Electrode Suitable for Reversible Charge Injection in Saline Solution
Robblee, L. S., Lefko, J. L., & Brummer, S. B. (1983) · Journal of The Electrochemical Society · doi:10.1149/1.2119793 · Cited by 227
Historical evolution of circuit models for the electrode-electrolyte interface
Geddes, L. A. (1997) · Annals of Biomedical Engineering · doi:10.1007/bf02738534 · Cited by 221
Beebe, X., & Rose, T. L. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.2122 · Cited by 219
Brummer, S. B., Robblee, L. S., & Hambrecht, F. T. (1983) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1983.tb31628.x · Cited by 205
The A‐C Response of Iridium Oxide Films
Glarum, S. H., & MARSHALL, J. H. (1980) · Journal of The Electrochemical Society · doi:10.1149/1.2129932 · Cited by 178
Histopathologic evaluation of prolonged intracortical electrical stimulation
Agnew, W. F., Yuen, T. G. H., McCreery, D. B., & Bullara, L. A. (1986) · Experimental Neurology · doi:10.1016/0014-4886(86)90132-9 · Cited by 173
A model for anodic hydrous oxide growth at iridium
Pickup, P. G., & Birss, V. I. (1987) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(87)88006-3 · Cited by 137
Brummer, S. B., & Turner, M. J. (1975) · Bioelectrochemistry and Bioenergetics · doi:10.1016/0302-4598(75)80002-x · Cited by 132
Valency and Structure of Iridium in Anodic Iridium Oxide Films
Hüppauff, M., & Lengeler, B. (1993) · Journal of The Electrochemical Society · doi:10.1149/1.2056127 · Cited by 101
Neuronal activity evoked by chronically implanted intracortical microelectrodes
McCreery, D. B., Bullara, L. A., & Agnew, W. F. (1986) · Experimental Neurology · doi:10.1016/0014-4886(86)90131-7 · Cited by 65
A 16-channel CMOS neural stimulating array
Tanghe, S., & Wise, K. D. (1992) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.173111 · Cited by 55
Effects of Electrical Stimulation of Brain
Pudenz, R. H., Agnew, W. F., & Bullara, L. A. (2008) · Brain Behavior and Evolution · doi:10.1159/000125578 · Cited by 42
Impedance of hydrated iridium oxide electrodes
Aurian‐Blajeni, B., Beebe, X., Rauh, R. D., & Rose, T. L. (1989) · Electrochimica Acta · doi:10.1016/0013-4686(89)87112-9 · Cited by 41
Electrical Characteristics of Chronically Implanted Platinum-Irdium Electrodes
Creery, D. B. M., Agnew, W. F., & Hardy, J. M. (1987) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1987.325990 · Cited by 16
Integrity of ultramicro-stimulation electrodes determined from electrochemical measurements
Twardoch, U. M. (1994) · Journal of Applied Electrochemistry · doi:10.1007/bf00348771 · Cited by 9
Cited by
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078
Conducting polymers in biomedical engineering
Guimard, N. K., Gomez, N., & Schmidt, C. E. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.05.012 · Cited by 1,599
Wireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656
Self-citationBrain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
Surface modification of neural recording electrodes with conducting polymer/biomolecule blends
Cui, X., Lee, V. A., Raphael, Y., Wiler, J. A., Hetke, J. F., Anderson, D. J., & Martin, D. C. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200108)56:2<261::aid-jbm1094>3.0.co;2-i · Cited by 530
Self-citation
Metadata
- Authors
- Weiland, J. D., & Anderson, D. J.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2000-07
- Volume
- 47
- Issue
- 7
- Pages
- 911-918
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2103865918
- Cited by
- 262
- References
- 23
- FWCI
- 1.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.