The DOI matches its Crossref record; 11 of the 13 references it cites were found in a registry or an index.
Artifact-resistant power-efficient design of finger-ring plethysmographic sensors
Abstract
A miniaturized, telemetric, photoplethysmograph (PPG) sensor for long-term, continuous monitoring is presented in this paper. The sensor, called a "ring sensor," is attached to a finger base for monitoring beat-to-beat pulsation, and the data is sent to a host computer via a radio-frequency transmitter. Two major design issues are addressed: one is to minimize motion artifact and the other is to minimize the consumption of battery power. An efficient double ring design is developed to lower the influence of external force, acceleration, and ambient light, and to hold the sensor gently and securely on the skin, so that the circulation at the finger may not be obstructed. Total power consumption is analyzed in relation to characteristics of individual components, sampling rate, and CPU clock speed. Optimal operating conditions are obtained for minimizing the power budget. A prototype ring sensor is designed and built based on the power budget analysis and the artifact-resistive attachment method. It is verified through experiments that the ring sensor is resistant to interfering forces and acceleration acting on the ring body. Benchmarking tests with FDA-approved PPG and electrocardiogram reveal that the ring sensor is comparable to those devices in detecting beat-to-beat pulsation despite disturbances.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This band would apply a skin pressure of about 75 mmHg and, due to its compliance, it would hold steady the applied pressure while the finger was in different positions.”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [213]
Citations
Cites
Holter, N. J. (1961) · Science · doi:10.1126/science.134.3486.1214 · Cited by 566
Berecek, K. H. (1975) · Nursing Clinics of North America · doi:10.1016/s0029-6465(22)00465-0 · Cited by 411
Etiologic factors in pressure sores: an experimental model.
Daniel, R. K., Priest, D., & Wheatley, D. (1981) · PubMed · Cited by 374
The ring sensor: a new ambulatory wearable sensor for twenty-four hour patient monitoring
Rhee, S., Yang, B.-H., Chang, K., & Asada, H. H. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1998.746970 · Cited by 90
Self-citationContinuous electrocardiographic monitoring during automobile driving
Bellet, S., Roman, L. R., Kostis, J. B., & Slater, A. (1968) · The American Journal of Cardiology · doi:10.1016/0002-9149(68)90183-5 · Cited by 72
A twenty-four hour tele-nursing system using a ring sensor
Yang, B.-H., Rhee, S., & Asada, H. H. (2002) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.1998.676438 · Cited by 63
Self-citationMeasurement of pulse-wave velocity using a beat-sampling technique
Pruett, J. D., BOURLAND, J. D., & Geddes, L. A. (1988) · Annals of Biomedical Engineering · doi:10.1007/bf02364622 · Cited by 53
Ischemic and pressure-induced hyperemia: A comparison
Rendell, M., & Wells, J. M. (1998) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(98)90243-x · Cited by 17
DEVELOPMENT OF A RING-TYPE VITAL SIGN TELEMETER
Yamashita, M., SHIMIZU, K., & Matsumoto, G. (1995) · Medical Entomology and Zoology · Cited by 13
Ambulatory monitoring of the cardiac patient.
David, D., Michelson, E. L., & Dreifus, L. S. (1988) · PubMed · Cited by 4
Flagged first, then by citations
2 of the 13 references couldn’t be matched to a known paper.
Research works printed but not linked: 2
- hayes, 1998, quantitative investigation of artefact in photo-plethysmography and pulse-oximetry for respiratory exercise testing, Proc CNVD 97 Frontiers in Computer-Aided Visualization of Vascular Functions, 117
- dinsdale, 1970, Mechanical factors in pathogenesis of ischemic skin ulcers in swine
Cited by
Sorted by citations
Items 101–200 of 234
Costa, T. B. D. S., Dias, F. M., Cárdenas, D. A. C., de Toledo, M. A. F., de Lima, D. M., Krieger, J. E., & Gutierrez, M. A. (2023) · IEEE Access · doi:10.1109/access.2023.3284458 · Cited by 21
Investigating the impact of contact pressure on photoplethysmograms
Sirkiä, J., Panula, T., & Kaisti, M. (2024) · Biomedical Engineering Advances · doi:10.1016/j.bea.2024.100123 · Cited by 26
Motion tolerance in wearable sensors - The challenge of motion artifact
Such, O. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4352597 · Cited by 20
A 0.5-Hz High-Pass Cutoff Dual-Loop Transimpedance Amplifier for Wearable NIR Sensing Device
Wong, A., Leung, K. N., Pun, K., & Zhang, Y. (2010) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2010.2048401 · Cited by 20
Zhu, H., Yu, H., Zhang, J., Zhang, Y., Zhang, L., Liu, S., & Xie, W. (2024) · Laser & Photonics Review · doi:10.1002/lpor.202400042 · Cited by 19
Evaluation of Bluetooth Hands-Free profile for sensors applications in smartphone platforms
Dominicis, C. M. D., Mazzotti, D., Piccinelli, M., Rinaldi, S., Vezzoli, A., & Depari, A. (2012) · IEEE Sensors Applications Symposium (SAS) · doi:10.1109/sas.2012.6166305 · Cited by 18
Stimulating Student Learning With A Novel “In House” Pulse Oximeter Design
Warren, S., & Yao, J. (2020) · IEEE Lasers and Electro-Optics Society Annual Meeting (LEOS) · doi:10.18260/1-2--14974 · Cited by 18
Designing of a prototype of e-health monitoring system
Biswas, S., & Misra, S. (2015) · International Conference on Research in Computational Intelligence and Communication Networks (ICRCICN) · doi:10.1109/icrcicn.2015.7434248 · Cited by 18
Novel Design for a Wearable, Rapidly Deployable, Wireless Noninvasive Triage Sensor
Shaltis, P., Wood, L. B., Reisner, A. T., & Asada, H. H. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2005.1617250 · Cited by 17
Self-citationHome-Telecare of the elderly living alone using an new designed ear-wearable sensor
Wang, C., & Zheng, Y. (2008) · IEEE/EMBS International Summer School on Medical Devices and Biosensors (ISSS-MDBS) · doi:10.1109/issmdbs.2008.4575019 · Cited by 16
Chen, T., Liu, Z., Zhang, L., Wu, H., Wu, G., & Chen, H. (2023) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.3c10338 · Cited by 15
A Context-Aware Indoor Air Quality System for Sudden Infant Death Syndrome Prevention
de la Iglesia, D. H., Paz, J. F. D., González, G. V., Barriuso, A. L., & Bajo, J. (2018) · Sensors · doi:10.3390/s18030757 · Cited by 15
Pujary, C. J. (2004) · Digital WPI · Cited by 15
Julián, P. A., Kontaxis, S., Rapalis, A., Marozas, V., Laguna, P., Bailón, R., Gil, E., & Lázaro, J. M. (2022) · Frontiers in Electronics · doi:10.3389/felec.2022.906324 · Cited by 14
Wireless monitoring of cardiac activity: a critical review
Fariborzi, H., & Moghavvemi, M. (2008) · International Journal of Biomedical Engineering and Technology · doi:10.1504/ijbet.2009.021905 · Cited by 14
A 15/spl times/15 mm, 1 /spl mu/A, reliable sensor-net module: enabling application-specific nodes
Yamashita, S., Shimura, T., Aiki, K., Ara, K., Ogata, Y., Shimokawa, I., Tanaka, T., Kuriyama, H., Shimada, K., & Yano, K. (2006) · ACM/IEEE International Conference on Information Processing in Sensor Networks (IPSN) · doi:10.1109/ipsn.2006.243877 · Cited by 14
Development of reusable and expandable communication for wearable medical sensor network
Park, D. G., & Kang, S. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2004.1404502 · Cited by 13
Mao, P., Li, H., Shan, X., Davis, M., Tang, T., Zhang, Y., Tong, X., Xin, Y., Cheng, J., Li, L., et al. (2023) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.3c04494 · Cited by 12
Sawangjai, P., Seesawad, N., & Wilaiprasitporn, T. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3529546 · Cited by 13
From Enabling Technology to Clinical Applications
Bonato, P. (2010) · Cited by 12
Application of photoplethysmography in blood flow measurement
Sangurmath, S., & Daimiwal, N. (2015) · International Conference on Industrial Instrumentation and Control · doi:10.1109/iic.2015.7150877 · Cited by 12
PPG pulse direction determination algorithm for PPG waveform inversion by wrist rotation
Choi, C., Ko, B.-H., Lee, J., Yoon, S. K., Kwon, U.-K., Kim, S. J., & Kim, Y. (2017) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2017.8037755 · Cited by 12
Wearable Photoplethysmographic Sensor System with PSoC Microcontroller
Sonoda, K., Kishida, Y., Tanaka, T., Kanda, K., Fujita, T., Higuchi, K., & Maenaka, K. (2013) · International Journal of Intelligent Computing in Medical Sciences & Image Processing · doi:10.1080/1931308x.2013.795034 · Cited by 11
Design of a Low-power Microcontroller-based Wireless ECG Monitoring System
Fariborzi, H., Moghavvemi, M., & Mehrkanoon, S. (2007) · IEEE Student Conference on Research and Development (SCOReD) · doi:10.1109/scored.2007.4451383 · Cited by 11
Wood, L. B. (2008) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 11
Calculation of blood pulse transit time from PPG
Bhavirisetty, R. T. (2012) · Cited by 11
From Telemedicine to Ubiquitous M-Health
Raŝković, D., Milenković, A., de Groen, P. C., & Jovanov, E. (2008) · Elsevier eBooks · doi:10.1016/b978-012373583-6.50026-8 · Cited by 10
Reflective Photoplethysmograph Earpiece Sensor for Ubiquitous Heart Rate Monitoring
Wang, L., Lo, B. P. L., & Yang, G. Z. (2007) · Springer eBooks · doi:10.1007/978-3-540-70994-7_31 · Cited by 10
Chiang, P.-Y., Chao, P. C.-P., Yang, C., & Tarng, D. (2018) · Microsystem Technologies · doi:10.1007/s00542-018-3892-4 · Cited by 10
A Novel Photodiode for Reflectance Pulse Oximetry in low-power applications
Haahr, R. G., Duun, S., Birkelund, K., Raahauge, P., Petersen, P., Dam, H. F., Nørgaard, L., & Thomsen, E. V. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4352798 · Cited by 10
An Overview of Technologies Related to Care for Venous Leg Ulcers
Hegarty‐Craver, M., Grant, E., & Reid, L. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2036009 · Cited by 10
A Photoplethysmograph Experiment for Microcontroller Labs
Gingl, Z. (2012) · International Journal of Electrical Engineering Education · doi:10.7227/ijeee.49.1.4 · Cited by 9
Plug-and-play, single-chip photoplethysmography
Chandrasekar, D., Arnetz, B. B., Levy, P., & Basu, A. S. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346656 · Cited by 9
Development of a wearable system integrated with novel biomedical sensors for ubiquitous healthcare
Hung, K., Lee, C. C., Chan, W.-M., Choy, S., & Kwok, P. C. K. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6347313 · Cited by 10
Han, B., Ivanov, K., Wang, L., & Yan, Y. (2015) · Wireless Mobile Communication and Healthcare · doi:10.4108/eai.14-10-2015.2261689 · Cited by 9
FitBeat: A Lightweight System for Accurate Heart Rate Measurement during Exercise
Tu, L., Huang, J., Bi, C., & Xing, G. (2017) · IEEE International Conference on Smart Computing · doi:10.1109/smartcomp.2017.7947009 · Cited by 9
An optical sensing approach based on light emitting diodes
Stojanovic, R. D., & Karadaglić, D. (2007) · Journal of Physics Conference Series · doi:10.1088/1742-6596/76/1/012054 · Cited by 9
Wang, L., Chen, F., Zhou, B., Xu, H., Meng, J., & Li, F. (2025) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5c09211 · Cited by 8
Ring sensor and heart rate monitoring system for sensor network applications
Jang, I.-H., Yeom, H.-G., & Sim, K.-B. (2008) · Electronics Letters · doi:10.1049/el:20082666 · Cited by 8
A Novel Ring Shaped Photodiode for Reflectance Pulse Oximetry in Wireless Applications
Duun, S., Haahr, R. G., Birkelund, K., Raahauge, P., Petersen, P., Dam, H. F., Noergaard, L., & Thomsen, E. V. (2007) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2007.4388469 · Cited by 8
TAMURA, T., & Maeda, Y. (2017) · Springer eBooks · doi:10.1007/978-3-319-69362-0_6 · Cited by 11
Kornikov, A. I., Kozlov, M. I., Vashchenko, A. A., Pavlov, A. A., Gordeeva, E. O., Latipov, E. V., Lepnev, L. S., Kozhevnikova, V. Y., & Utochnikova, V. V. (2023) · ACS Applied Optical Materials · doi:10.1021/acsaom.3c00124 · Cited by 7
Performance Evaluation of Healthcare Monitoring System over Heterogeneous Wireless Networks
Manfredi, S. (2012) · E-Health Telecommunication Systems and Networks · doi:10.4236/etsn.2012.13005 · Cited by 7
Trade-offs for low power integrated pulse oximeters
Glaros, K. N., & Drakakis, E. M. (2009) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2009.5372039 · Cited by 7
Heart Rate and Blood Pressure Estimation from Compressively Sensed Photoplethysmograph
Baheti, P. K., & Garudadri, H. (2009) · International Conference on Body Area Networks · doi:10.4108/icst.bodynets2009.6023 · Cited by 7
Pulse Oximetry in the External Auditory Canal– A New Method of Mobile Vital Monitoring
Buschmann, J. P., & Huang, J. (2011) · IEEE Sensors Journal · doi:10.1109/jsen.2011.2147780 · Cited by 7
Mendelson, Y. (2006) · Wiley Encyclopedia of Biomedical Engineering · doi:10.1002/9780471740360.ebs0990 · Cited by 7
A Robust PPG-based Heart Rate Monitor for Fitness and eHealth Applications
Shokrekhodaei, M., Quiñones, S., Martínek, R., & Nazeran, H. (2018) · IEEE International Conference on e-Health Networking, Applications and Services (Healthcom) · doi:10.1109/healthcom.2018.8531082 · Cited by 6
A personal healthcare system for contact-less estimation of cardiovascular parameters
Pasquadibisceglie, V., Zaza, G., & Castellano, G. (2018) · AEIT International Annual Conference · doi:10.23919/aeit.2018.8577458 · Cited by 6
A Novel Reflection Pulse Oximeter for Home Health Care Applications
Yuan, Z., Fang, Z., Chen, X. X., Xu, Z. H., Chen, D., Zhao, Z., & Xia, S. H. (2014) · International Conference on Intelligent System Design and Engineering Application (ISDEA) · doi:10.1109/isdea.2014.23 · Cited by 6
Portable photoplethysmogram acquisition and analysis instrument
Alam, S., & Gupta, R. (2016) · International Conference on Control, Instrumentation, Energy & Communication · doi:10.1109/ciec.2016.7513775 · Cited by 6
Proposta de um sistema telemétrico para aquisição de sinais fisiológicos
Schwarz, L. (2007) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) · Cited by 6
Gui, H., & Liu, J. (2018) · arXiv (Cornell University) · doi:10.48550/arxiv.1802.01747 · Cited by 11
PPGANet: Removal of Motion Artifacts from the PPG Signal Using Generative Adversarial Networks
Sawangjai, P., & Wilaiprasitporn, T. (2023) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas58349.2023.10388620 · Cited by 5
Blood oxygen estimation from compressively sensed photoplethysmograph
Baheti, P. K., Garudadri, H., & Majumdar, S. (2010) · Wireless Health · doi:10.1145/1921081.1921084 · Cited by 5
Effect of change in intensity of infrared LED on a photoplethysmogram
Shriram, R., Sundhararajan, M., & Daimiwal, N. (2014) · doi:10.1109/iccsp.2014.6950010 · Cited by 5
Multi-Sensor Wireless Physiological Monitor Module
Ko, C. H., Chen, H. L., Kuo, C. ‐. J., Yang, G., Yeh, C.-Y., Tsai, B.-H., Chiou, Y. T., & Chu, C. H. (2006) · IEEE Electronic Components and Technology Conference (ECTC) · doi:10.1109/ectc.2006.1645723 · Cited by 5
Nonintrusive measurement of biological signals for ubiquitous healthcare
Park, K. S. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5334000 · Cited by 5
Pamula, V. R., Hoof, C. A. V., & Verhelst, M. (2017) · Springer eBooks · doi:10.1007/978-3-319-61285-0_8 · Cited by 5
Ibrahem, H. A., Atef, M., & Khaled, E. E. M. (2019) · National Radio Science Conference · doi:10.1109/nrsc.2019.8734533 · Cited by 5
Yen, C.-T., Chang, S., & Cai, C.-Y. (2021) · Journal of Nanomaterials · doi:10.1155/2021/6613817 · Cited by 5
Rhee, S., Yang, B.-H., & Asada, H. H. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2000.901444 · Cited by 5
Self-citationStone-Type Physiological Sensing Device for Daily Monitoring in an Ambient Intelligence Environment
Choi, A., Oh, Y., Park, G., & Woo, W. (2008) · Lecture notes in computer science · doi:10.1007/978-3-540-89617-3_22 · Cited by 5
Benchmarking of Sensor Configurations and Measurement Sites for Out-of-the-Lab Photoplethysmography
Supelnic, M. N., Ferreira, A. F., Bota, P. J., Rosário, L. B., & Silva, H. (2023) · Sensors · doi:10.3390/s24010214 · Cited by 4
System for Simultaneous Measurement of Breathing Rate and Heart Rate using Photoplethysmogram
Kagawa, T., 河本, 温., & Nakajima, N. (2013) · International Conference on Body Area Networks · doi:10.4108/icst.bodynets.2013.253646 · Cited by 4
Ultra Low Power ASIC for R-R Interval Extraction on Wearable Health Monitoring System
Fujita, T., Tanaka, T., Sonoda, K., Kanda, K., & Maenaka, K. (2013) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc.2013.645 · Cited by 4
Ratiometric Artefact Reduction in Low Power, Discrete-Time, Reflective Photoplethysmography
Patterson, J. A. C., & Yang, G. (2010) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2010.33 · Cited by 4
Low complexity sensors for body area networks
Garudadri, H., Baheti, P. K., & Majumdar, S. (2010) · International Conference on PErvasive Technologies Related to Assistive Environments (PETRA) · doi:10.1145/1839294.1839360 · Cited by 4
A Near-Infrared Non-invasive imager using Correlated Double Sampling
Wong, A., Gangavarapu, K. K., Newcomer, M., & Chance, B. (2006) · IEEE/EMBS International Summer School on Medical Devices and Biosensors (ISSS-MDBS) · doi:10.1109/issmd.2004.1689557 · Cited by 4
Wireless portable sensor for athletic monitoring
Rossetto, L. T., Müller, I., Brusamarello, V. J., Fabris, E., & Pereira, C. E. (2012) · IEEE International Instrumentation and Measurement Technology Conference · doi:10.1109/i2mtc.2012.6229683 · Cited by 4
Jovanov, E., & Raŝković, D. (2007) · Springer eBooks · doi:10.1007/0-387-26559-7_3 · Cited by 4
Heart Rate Monitoring Using a Slow–Fast Adaptive Comb Filter to Eliminate Motion Artifacts
Chuang, C.-T., Chang, T., Chiang, Y.-T., & Chang, F. (2016) · Journal of Medical and Biological Engineering · doi:10.1007/s40846-016-0183-3 · Cited by 4
Bhattacharya, T., Gupta, A., Singh, S. T., Roy, S., & Prasad, A. (2017) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2017.8037624 · Cited by 3
Li, K., & Warren, S. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091812 · Cited by 3
An approach to monitoring of physiological signals using Bluetooth
Stojanovic, R. D., Tafa, Ž., & Lekić, N. (2006) · International Conference on Applied Electronics · doi:10.1109/ae.2006.4382995 · Cited by 3
Jayasree, V. K., Shaija, P. J., Nampoori, V. P. N., Girijavallabhan, C. P., & Radhakrishnan, P. (2007) · International Journal of Optomechatronics · doi:10.1080/15599610701779325 · Cited by 3
An ultra-low power, self-organizing wireless network and non-invasive biomedical instrumentation
Rhee, S., & Liu, S. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2002.1053033 · Cited by 3
Self-citationHeart Rate Monitor for Portable MP3 Player
Kim, J., Lee, M.-H., Lee, H.-K., Choi, K., Bang, S., & Kim, S. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2005.1615652 · Cited by 3
Ease of Use Considerations for Wearable Point-Of-Care Devices in Home Environments
Yao, J., Simmons, S., & Warren, S. (2006) · Transdisciplinary Conference on Distributed Diagnosis and Home Healthcare (D2H2) · doi:10.1109/ddhh.2006.1624784 · Cited by 3
Wireless monitoring and analysis of PPG signal for assessment of cardiovascular system in real time
Jayadevappa, B. M., & Holi, M. S. (2016) · International Journal of Bioinformatics Research and Applications · doi:10.1504/ijbra.2016.075397 · Cited by 3
Li, K., & Warren, S. (2020) · ASEE Annual Conference & Exposition · doi:10.18260/1-2--16621 · Cited by 3
Case Study on Measurement of SpO2 from PPG Signals in the Presence of Motion Artifact
Subhagya, D. S., Keshava Murthy., C., Aruna, N., Janardhan, L., & Ramakrishna, H. S. (2017) · International Conference on Recent Advances in Electronics and Communication Technology (ICRAECT) · doi:10.1109/icraect.2017.71 · Cited by 3
Chan, P.-K., Chang, T.-C., Chen, K.-W., & Yang, C. (2018) · IEEE MTT-S International Microwave Biomedical Conference (IMBioC) · doi:10.1109/imbioc.2018.8428881 · Cited by 3
Ioachimescu, O. C. (2022) · SLEEP · doi:10.1093/sleep/zsac057 · Cited by 3
Moghaddam, M., Collins, J. P., Gardner, C. E., & Rabel, M. C. (2025) · Sensors · doi:10.3390/s26010176 · Cited by 3
Photoplethysmography for Measuring Cognitive Load in XR Environments: A Systematic Review
Alshehhi, A., Abbasi, Q. H., & Ghannam, R. (2026) · Advanced Sensor Research · doi:10.1002/adsr.202500142 · Cited by 2
DAILY PHYSIOLOGICAL SIGNAL MONITORING SYSTEM FOR FOSTERING SOCIAL WELL-BEING IN SMART SPACES
Choi, A., & Woo, W. (2010) · Cybernetics & Systems · doi:10.1080/01969721003685128 · Cited by 2
Development of a multi-source, multi-detector, finger photoplethysmography system
Branan, K. L., McMurray, J. P., Hsiao, C., & Coté, G. L. (2023) · Optical Diagnostics and Sensing: Toward Point-of-Care Diagnostics · doi:10.1117/12.2648619 · Cited by 2
A Near-Infrared Heart Rate Sensor IC With Very Low Cutoff Frequency using Current Steering Technique
Wong, A., Pun, K., Zhang, Y., & Hung, K. (2005) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2005.1465189 · Cited by 2
Heartbeat Interval Error Compensation Method for Low Sampling Rates Photoplethysmography Sensors
Watanabe, K., Izumi, S., Yano, Y., Kawaguchi, H., & Yoshimoto, M. (2019) · IEICE Transactions on Communications · doi:10.1587/transcom.2019hmp0002 · Cited by 2
Shriram, R., Sundhararajan, M., & Daimiwal, N. (2014) · IEEE International Conference for Convergence in Technology (I2CT) · doi:10.1109/i2ct.2014.7092340 · Cited by 2
Li, K., & Warren, S. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346369 · Cited by 2
Mithun, J. A., Rajkumar, V. V., & Shanmugapriya (2006) · IEEE Annual Northeast Bioengineering Conference (NEBEC) · doi:10.1109/nebc.2006.1629822 · Cited by 2
Development of a digital finger photoplethysmogram sensor
Kulminskiy, D. D., Kurbako, A. V., Skazkina, V. V., Prokhorov, M. D., Пономаренко, В. И., Kiselev, A. R., Bezruchko, B. P., & Karavaev, A. S. (2021) · Izvestiya of Saratov University Physics · doi:10.18500/1817-3020-2021-21-1-58-68 · Cited by 2
Gan, K. B., & Pua, H. L. (2021) · International Journal on Robotics Automation and Sciences · doi:10.33093/ijoras.2021.3.2 · Cited by 2
Internet of Everything: Applications
Wajgi, R. D., Tembhurne, J. V., Wajgi, D. W., & Jain, T. K. (2023) · Internet of things · doi:10.1007/978-3-031-09955-7_9 · Cited by 2
Feasibility study of a wearable carbon monoxide warning system for construction workers
Forsyth, J. B., Martin, T. L., Young-Corbett, D. E., & Dorsa, E. (2011) · IEEE International Conference on Pervasive Computing and Communications · doi:10.1109/percom.2011.5767592 · Cited by 1
LED-LED PPG-SPO2 SENSOR-ACTUATOR
Stojanovic, R. D., Karadaglić, D., Perakis, K., Lutovac, B. M., Haritou, M., & Koutsoris, D. (2008) · Cited by 1
Liquid Metal Enabled Wearable Electronics
Liu, J., & Yi, L. (2018) · Springer series in biomaterials science and engineering · doi:10.1007/978-981-10-5607-9_14 · Cited by 1
Wearable electrochemical and biosensors for forensic analysis: Challenges and research directions
Kaswan, K. S., Dhatterwal, J. S., & Kumar, S. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-13792-1.00015-8 · Cited by 1
Metadata
- Authors
- Rhee, S., Yang, B.-H., & Asada, H. H.
- Affiliations
- Massachusetts Institute of Technology (US)
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2001-07
- Volume
- 48
- Issue
- 7
- Pages
- 795-805
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2159079926
- Cited by
- 235
- References
- 13
- Citations by year
- 2026: 3 · 2025: 4 · 2024: 4 · 2023: 10 · 2022: 5 · 2021: 9 · 2020: 9 · 2019: 10 · 2018: 16 · 2017: 10 · 2016: 3 · 2015: 7 · 2014: 16 · 2013: 9 · 2012: 18
- FWCI
- 3.17
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Keywords
- photoplethysmography, power consumption, telemetry monitoring, wearable sensors, ambient light interference, sampling rate optimization
- MeSH terms
- Adult, Algorithms, Equipment Design, Fingers, Humans, Male, Plethysmography, Electric Power Supplies, Pressure, Pulsatile Flow, Reference Values, Signal Processing, Computer-Assisted, Reproducibility of Results, Artifacts, Monitoring, Ambulatory, Benchmarking
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review