The DOI matches its Crossref record; 11 of the 13 references it cites were found in a registry or an index.
Artifact-resistant power-efficient design of finger-ring plethysmographic sensors
Abstract
A miniaturized, telemetric, photoplethysmograph (PPG) sensor for long-term, continuous monitoring is presented in this paper. The sensor, called a "ring sensor," is attached to a finger base for monitoring beat-to-beat pulsation, and the data is sent to a host computer via a radio-frequency transmitter. Two major design issues are addressed: one is to minimize motion artifact and the other is to minimize the consumption of battery power. An efficient double ring design is developed to lower the influence of external force, acceleration, and ambient light, and to hold the sensor gently and securely on the skin, so that the circulation at the finger may not be obstructed. Total power consumption is analyzed in relation to characteristics of individual components, sampling rate, and CPU clock speed. Optimal operating conditions are obtained for minimizing the power budget. A prototype ring sensor is designed and built based on the power budget analysis and the artifact-resistive attachment method. It is verified through experiments that the ring sensor is resistant to interfering forces and acceleration acting on the ring body. Benchmarking tests with FDA-approved PPG and electrocardiogram reveal that the ring sensor is comparable to those devices in detecting beat-to-beat pulsation despite disturbances.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This band would apply a skin pressure of about 75 mmHg and, due to its compliance, it would hold steady the applied pressure while the finger was in different positions.”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [213]
Citations
Cites
Holter, N. J. (1961) · Science · doi:10.1126/science.134.3486.1214 · Cited by 566
Berecek, K. H. (1975) · Nursing Clinics of North America · doi:10.1016/s0029-6465(22)00465-0 · Cited by 411
Etiologic factors in pressure sores: an experimental model.
Daniel, R. K., Priest, D., & Wheatley, D. (1981) · PubMed · Cited by 374
The ring sensor: a new ambulatory wearable sensor for twenty-four hour patient monitoring
Rhee, S., Yang, B.-H., Chang, K., & Asada, H. H. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1998.746970 · Cited by 90
Self-citationContinuous electrocardiographic monitoring during automobile driving
Bellet, S., Roman, L. R., Kostis, J. B., & Slater, A. (1968) · The American Journal of Cardiology · doi:10.1016/0002-9149(68)90183-5 · Cited by 72
A twenty-four hour tele-nursing system using a ring sensor
Yang, B.-H., Rhee, S., & Asada, H. H. (2002) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.1998.676438 · Cited by 63
Self-citationMeasurement of pulse-wave velocity using a beat-sampling technique
Pruett, J. D., BOURLAND, J. D., & Geddes, L. A. (1988) · Annals of Biomedical Engineering · doi:10.1007/bf02364622 · Cited by 53
Ischemic and pressure-induced hyperemia: A comparison
Rendell, M., & Wells, J. M. (1998) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(98)90243-x · Cited by 17
DEVELOPMENT OF A RING-TYPE VITAL SIGN TELEMETER
Yamashita, M., SHIMIZU, K., & Matsumoto, G. (1995) · Medical Entomology and Zoology · Cited by 13
Ambulatory monitoring of the cardiac patient.
David, D., Michelson, E. L., & Dreifus, L. S. (1988) · PubMed · Cited by 4
Flagged first, then by citations
2 of the 13 references couldn’t be matched to a known paper.
Research works printed but not linked: 2
- hayes, 1998, quantitative investigation of artefact in photo-plethysmography and pulse-oximetry for respiratory exercise testing, Proc CNVD 97 Frontiers in Computer-Aided Visualization of Vascular Functions, 117
- dinsdale, 1970, Mechanical factors in pathogenesis of ischemic skin ulcers in swine
Cited by
Sorted by citations
Items 201–234 of 234
Daisy-chain Shape Wearable Health Monitoring System by Using Fuzzy Logic Heart-Rate Extraction
Fujita, T., Tanaka, T., Sonoda, K., Nii, M., Kanda, K., Higuchi, K., & Maenaka, K. (2013) · International Journal of Intelligent Computing in Medical Sciences & Image Processing · doi:10.1080/1931308x.2013.847621 · Cited by 1
Thiagarajan, S., & Balleda, K. (2014) · International Conference on High Performance Computing and Applications (ICHPCA) · doi:10.1109/ichpca.2014.7045358 · Cited by 1
A Correlation Study on Motion Artifact using Photodiode and Three Axis Accelerometer Signals
Hasan, M. A., Samsuri, F., & Gan, K. B. (2017) · Indian Journal of Science and Technology · doi:10.17485/ijst/2017/v10i7/111457 · Cited by 1
Detección de las frecuencias cardiaca y respiratoria mediante una báscula electrónica
Landaeta, R. G., Casas, Ó., & Pallas-Areny, R. (2007) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-540-74471-9_104 · Cited by 1
Neural Network based Activity Tracker
Abu-Khalaf, J., Bouri, S. E., Giha, N., Al-Chalabi, L., & Al-Halhouli, A. T. (2018) · International Conference on Research and Education in Mechatronics (REM) · doi:10.1109/rem.2018.8421775 · Cited by 1
Early Detection of Inpatient Deterioration Using Wearable Monitors
Bonnici, T. (2019) · doi:10.13140/rg.2.2.26843.92967 · Cited by 1
Sensors for Vital Signs: Oxygen Sensors
Glaros, K. N., Rogers, M. L., Boutelle, M. G., & Drakakis, E. M. (2022) · Springer eBooks · doi:10.1007/978-1-4614-3447-4_3 · Cited by 1
TAMURA, T. (2006) · Encyclopedia of Medical Devices and Instrumentation · doi:10.1002/0471732877.emd131 · Cited by 1
Işık, C. (2006) · Encyclopedia of Medical Devices and Instrumentation · doi:10.1002/0471732877.emd038 · Cited by 1
Signal quality classification for an ambulatory monitoring system
Fu, Y., Bryan, H. S., Yang, I., & Lai, K. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5627482 · Cited by 1
Wearable Cyberphysical Systems for Biomedicine
Latif, T., Dieffenderfer, J. P., da Silva, R. L., Lobaton, E. J., & Bozkurt, A. Y. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-822548-6.00124-2 · Cited by 1
Characterisation and biomedical application of fabric sensors
Mestrovic, M. A. (2012) · RMIT Research Repository (RMIT University Library) · doi:10.25439/rmt.27351072
Schwarz, L., Paim, F. C. A., Sovierzoski, M. A., Neto, J. M., & Marques, J. L. B. (2007) · Springer eBooks · doi:10.1007/978-3-540-36841-0_199
A Ubiquitous Blood Pressure Sensor Worn at the Ear
Koizumi, H., Shimada, J., Uenishi, Y., & Tochikubo, O. (2009) · Japanese Journal of Applied Physics · doi:10.1143/jjap.48.127001
Design and Implementation of a Portable Pulse Wave Velocity Measuring Prototype
Guo, C., Wang, H. Y., Li, Y., Chen, Z. B., & Li, S. Y. (2014) · Applied Mechanics and Materials · doi:10.4028/www.scientific.net/amm.602-605.1829
Representation of Vital Signs in Minimal Parameter Set
Zhao, J., Wang, L., Mei, Z., & Guo, Y. W. (2010) · International Conference on Bioinformatics and Biomedical Engineering · doi:10.1109/icbbe.2010.5514798
A Fully Digital Approach in Sensing and Processing Photoplethysmographic Signal
Stojanovic, R. D., Ašanin, B., & Karadaglić, D. (2009) · International Conference on Biomedical Engineering and Informatics (BMEI) · doi:10.1109/bmei.2009.5305351
Kim, S.-J., & Lee, Y. (2012) · The Journal of the Korean Institute of Information and Communication Engineering · doi:10.6109/jkiice.2012.16.1.160
A pilot study on low power pulse rate detection based on compressive sampling
Huang, B., Wang, L., Wang, B., Lin, S., Wu, D., & Zhang, Y. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5332700
HASEGAWA, K., Kim, J., & NAKAJIMA, K. (2014) · Transactions of the Society of Instrument and Control Engineers · doi:10.9746/sicetr.50.588
THE EFFECTS OF EMISSION LIGHT PULSE WIDTH ON NON INVASIVE OPTICAL PLETHYSMOGRAPHIC DEVICES
Fang, Y.-C., & Tai, C.-C. (2014) · Instrumentation Science & Technology · doi:10.1080/10739149.2014.917427
Development of Disposable Adhesive Wearable Human-Monitoring System
Chan, A. C. K., Higuchi, K., & Maenaka, K. (2018) · CRC Press eBooks · doi:10.1201/9781351229067-15
Sensors for Vital Signs: Oxygen Sensors
Glaros, K. N., Rogers, M. L., Boutelle, M. G., & Drakakis, E. M. (2017) · Springer eBooks · doi:10.1007/978-1-4614-6623-9_3-1
Development of Disposable Adhesive Wearable Human-Monitoring System
Chan, A. C. K., Higuchi, K., & Maenaka, K. (2015) · CRC Press eBooks · doi:10.1201/b19210-19
Pamula, V. R., Hoof, C. A. V., & Verhelst, M. (2019) · Analog circuits and signal processing/Analog circuits and signal processing series · doi:10.1007/978-3-030-05870-8_6
Hung, K., & Zhang, Y. (2006) · Wiley Encyclopedia of Biomedical Engineering · doi:10.1002/9780471740360.ebs1178
(2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6345853
Investigation on Optical Sensors for Heart Rate Monitoring
Kaveri, V. V., Meenakshi, V., Kousika, N., & Pushpalatha, A. (2023) · doi:10.1002/9781119839569.ch1
Tactile Intelligence Enabled Pulse Oximeter for Motion Artifacts Removal
Zhou, S., Zhao, L., Fang, J., & Pan, T. (2025) · IEEE International Conference on Flexible and Printable Sensors and Systems (FLEPS) · doi:10.1109/fleps65444.2025.11105693
Exercise Heart Rate Measurement and Analysis Using Wearable Photoplethysmography
Zhang, C., Chen, T., Liu, H., Li, K., & Liu, G. (2026) · International Conference on Bioinformatics and Computational Biology (ICBCB) · doi:10.1109/icbcb69424.2026.11621331
AI Enabled IoT Vital Sign Monitoring System
Ahashmi, A., Alabbas, A., Alnaqbi, M., Belachew, C., & Alyammahi, M. (2026) · Student Multidisciplinary Innovation and Research Conference (SMIRC) · doi:10.1109/smirc70459.2026.11706678
Metadata
- Authors
- Rhee, S., Yang, B.-H., & Asada, H. H.
- Affiliations
- Massachusetts Institute of Technology (US)
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2001-07
- Volume
- 48
- Issue
- 7
- Pages
- 795-805
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2159079926
- Cited by
- 235
- References
- 13
- Citations by year
- 2026: 3 · 2025: 4 · 2024: 4 · 2023: 10 · 2022: 5 · 2021: 9 · 2020: 9 · 2019: 10 · 2018: 16 · 2017: 10 · 2016: 3 · 2015: 7 · 2014: 16 · 2013: 9 · 2012: 18
- FWCI
- 3.17
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Keywords
- photoplethysmography, power consumption, telemetry monitoring, wearable sensors, ambient light interference, sampling rate optimization
- MeSH terms
- Adult, Algorithms, Equipment Design, Fingers, Humans, Male, Plethysmography, Electric Power Supplies, Pressure, Pulsatile Flow, Reference Values, Signal Processing, Computer-Assisted, Reproducibility of Results, Artifacts, Monitoring, Ambulatory, Benchmarking
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review