The DOI matches its Crossref record.
10-MW GTO converter for battery peaking service
Abstract
A bidirectional 18-pulse voltage-source converter utilizing gate-turnoff thyristors (GTOs) is described. The converter, which is rated 10 MVA, was placed in service in early 1988 to connect an energy storage battery to a utility grid. The converter is rated and controlled to operate in all four quadrants (discharge, charge, leading VAr, or lagging VAr) at the full 10 MVA rating. It is capable of independent rapid control of real and reactive power with a transient response of 16 ms to changes in commanded value of real or reactive power. Thus it is usable as a reactive power controller (static VAr control), voltage control, frequency control, power system stabilizer, or real power peaking station. For use as a reactive power controller only, no battery would be needed. The design, construction, control, and application of the converter are described, and performance data taken at factory power test and at the installation are given.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Multilevel converters-a new breed of power converters
Lai, J.-S., & Peng, F. Z. (2002) · IAS '95. Conference Record of the 1995 IEEE Industry Applications Conference Thirtieth IAS Annual Meeting · doi:10.1109/ias.1995.530601 · Cited by 2,665
Multilevel converters-a new breed of power converters
Lai, J.-S., & Peng, F. Z. (1996) · IEEE Transactions on Industry Applications · doi:10.1109/28.502161 · Cited by 2,604
A Review of Three-Phase Improved Power Quality AC–DC Converters
Singh, B., Singh, B. N., Chandra, A., Al-Haddad, K., Pandey, A., & Kothari, D. P. (2004) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2004.825341 · Cited by 1,728
Energy storage systems for advanced power applications
Ribeiro, P. F., Johnson, B. K., Crow, M. L., Arsoy, A., & Liu, Y. (2001) · Proceedings of the IEEE · doi:10.1109/5.975900 · Cited by 1,058
Maharjan, L., Inoue, S., Akagi, H., & Asakura, J. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2014868 · Cited by 590
Multipulse AC–DC Converters for Improving Power Quality: A Review
Singh, B., Gairola, S., Singh, B. N., Chandra, A., & Al-Haddad, K. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.911880 · Cited by 412
Energy Management and Optimization Methods for Grid Energy Storage Systems
Byrne, R. H., Nguyen, T. A., Copp, D. A., Chalamala, B. R., & Gyuk, I. (2018) · IEEE Access · doi:10.1109/access.2017.2741578 · Cited by 406
Gabash, A., & Li, P. (2012) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2012.2187315 · Cited by 335
Dynamic Optimal Power Flow for Active Distribution Networks
Gill, S., Kockar, I., & Ault, G. W. (2014) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2013.2279263 · Cited by 334
Akagi, H., & Sato, H. (2002) · IEEE Transactions on Power Electronics · doi:10.1109/63.988676 · Cited by 332
A comparison of high-power converter topologies for the implementation of FACTS controllers
Soto, D., & Green, T. C. (2002) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2002.803217 · Cited by 288
Maharjan, L., Yamagishi, T., & Akagi, H. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2059045 · Cited by 278
Metadata
- Authors
- Walker, L. H.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 1990
- Volume
- 26
- Issue
- 1
- Pages
- 63-72
- ISSN
- 0093-9994 (ISSN-L)
- OpenAlex
- W2166151136
- Cited by
- 172
- References
- 0
- FWCI
- 2.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.