The DOI matches its Crossref record.
A comparison of high-power DC-DC soft-switched converter topologies
Abstract
The purpose of this paper is to compare the properties of several soft-switching converter topologies when used to achieve DC-DC conversion at high-power and high-voltage levels. As an example, a 100 kW transformer isolated converter with 700-1400 Vdc input is designed with an estimated mass in the 90-kg range and an energy efficiency of 95%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Forouzesh, M., Siwakoti, Y. P., Gorji, S. A., Blaabjerg, F., & Lehman, B. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2652318 · Cited by 2,123
Closed Form Solution for Minimum Conduction Loss Modulation of DAB Converters
Krismer, F., & Kolar, J. W. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2157976 · Cited by 635
Pwm control of dual active bridge: Comprehensive analysis and experimental verification
Jain, A. K., & Ayyanar, R. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2070519 · Cited by 567
Hou, N., & Li, Y. W. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2927930 · Cited by 553
Switching Control Strategy to Minimize Dual Active Bridge Converter Losses
Oggier, G. G., GarcÍa, G. O., & Oliva, A. R. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2020902 · Cited by 514
Characterization, Modeling, and Application of 10-kV SiC MOSFET
Wang, J., Zhao, T., Li, J., Huang, A. Q., Callanan, R., Husna, F., & Agarwal, A. (2008) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2008.926650 · Cited by 398
Bauman, J., & Kazerani, M. (2008) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2007.906379 · Cited by 363
High-Power Bidirectional DC–DC Converter for Aerospace Applications
Naayagi, R. T., Forsyth, A. J., & Shuttleworth, R. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2184771 · Cited by 305
An actively cooled high power, high frequency transformer with high insulation capability
Heinemann, L. (2003) · APEC. Seventeenth Annual IEEE Applied Power Electronics Conference and Exposition (Cat. No.02CH37335) · doi:10.1109/apec.2002.989270 · Cited by 135
Sfakianakis, G. E., Everts, J., & Lomonova, E. A. (2015) · 2015 Tenth International Conference on Ecological Vehicles and Renewable Energies (EVER) · doi:10.1109/ever.2015.7112939 · Cited by 47
Metadata
- Authors
- Steigerwald, R. L., De Doncker, R. W., & Kheraluwala, H.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 1996
- Volume
- 32
- Issue
- 5
- Pages
- 1139-1145
- ISSN
- 0093-9994 (ISSN-L)
- OpenAlex
- W2166967631
- Cited by
- 231
- References
- 0
- FWCI
- 2.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.