The DOI matches its Crossref record.
A wireless implantable multichannel digital neural recording system for a micromachined sieve electrode
Abstract
This paper reports the development of an implantable, fully integrated, multichannel peripheral neural recording system, which is powered and controlled using an RF telemetry link. The system allows recording of /spl plusmn/500 /spl mu/V neural signals from axons regenerated through a micromachined silicon sieve electrode. These signals are amplified using on-chip 100 Hz to 3.1 kHz bandlimited amplifiers, multiplexed, and digitized with a low-power (<2 mW), moderate speed (8 /spl mu/s/b) current-mode 8-b analog-to-digital converter (ADC). The digitized signal is transmitted to the outside world using a passive RF telemetry link. The circuit is implemented using a bipolar CMOS process. The signal processing CMOS circuitry dissipates only 10 mW of power from a 5-V supply while operating at 2 MHz and consumes 4/spl times/4 mm/sup 2/ of area. The overall circuit including the RF interface circuitry contains over 5000 transistors, dissipates 90 mW of power, and consumes 4/spl times/6 mm/sup 2/ of area.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656
Self-citationOptimal Frequency for Wireless Power Transmission Into Dispersive Tissue
Poon, A. S. Y., O'Driscoll, S., & Meng, T. H. (2010) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2010.2044310 · Cited by 469
Li, X., Tsui, C.-Y., & Ki, W.-H. (2015) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2014.2387832 · Cited by 302
A Wireless-Implantable Microsystem for Continuous Blood Glucose Monitoring
Ahmadi, M. M., & Jullien, G. A. (2009) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2009.2016844 · Cited by 266
Metadata
- Authors
- Akin, T., Najafi, K., & Bradley, R. M.
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 1998
- Volume
- 33
- Issue
- 1
- Pages
- 109-118
- ISSN
- 0018-9200 (ISSN-L)
- OpenAlex
- W2133897393
- Cited by
- 207
- References
- 0
- FWCI
- 1.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A wireless implantable multichannel digital neural recording system for a micromachined sieve electrode. https://app.cochat.ai/papers/10.1109/4.654942
- The paper
- Akin, T., Najafi, K., & Bradley, R. M. (1998). A wireless implantable multichannel digital neural recording system for a micromachined sieve electrode. IEEE Journal of Solid-State Circuits. https://doi.org/10.1109/4.654942
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.