The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
A CAD system for the automatic detection of clustered microcalcifications in digitized mammogram films
Abstract
Clusters of microcalcifications in mammograms are an important early sign of breast cancer. This paper presents a computer-aided diagnosis (CAD) system for the automatic detection of clustered microcalcifications in digitized mammograms. The proposed system consists of two main steps. First, potential microcalcification pixels in the mammograms are segmented out by using mixed features consisting of wavelet features and gray level statistical features, and labeled into potential individual microcalcification objects by their spatial connectivity. Second, individual microcalcifications are detected by using a set of 31 features extracted from the potential individual microcalcification objects. The discriminatory power of these features is analyzed using general regression neural networks via sequential forward and sequential backward selection methods. The classifiers used in these two steps are both multilayer feedforward neural networks. The method is applied to a database of 40 mammograms (Nijmegen database) containing 105 clusters of microcalcifications. A free-response operating characteristics (FROC) curve is used to evaluate the performance. Results show that the proposed system gives quite satisfactory detection performance. In particular, a 90% mean true positive detection rate is achieved at the cost of 0.5 false positive per image when mixed features are used in the first step and 15 features selected by the sequential backward selection method are used in the second step. However, we must be cautious when interpreting the results, since the 20 training samples are also used in the testing step.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neural Networks: A Comprehensive Foundation
Haykin, S. (1998) · Cited by 30,070
Textural Features for Image Classification
Haralick, R. M., Shanmugam, K., & Dinstein, I. (1973) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1973.4309314 · Cited by 22,886
Daubechies, I. (1992) · doi:10.1137/1.9781611970104 · Cited by 15,979
Daubechies, I., & Heil, C. (1992) · Computers in Physics · doi:10.1063/1.4823127 · Cited by 15,631
On Estimation of a Probability Density Function and Mode
Parzen, E. (1962) · The Annals of Mathematical Statistics · doi:10.1214/aoms/1177704472 · Cited by 10,585
Neural networks: A comprehensive foundation
Tadeusiewicz, R. (1995) · Control Engineering Practice · doi:10.1016/0967-0661(95)90080-2 · Cited by 7,218
A general regression neural network
Specht, D. F. (1991) · IEEE Transactions on Neural Networks · doi:10.1109/72.97934 · Cited by 4,492
Strang, G., & Nguyen, T. Q. (1996) · Cited by 4,180
Wavelets and signal processing
Rioul, O., & Vetterli, M. (1991) · IEEE Signal Processing Magazine · doi:10.1109/79.91217 · Cited by 2,786
Neural Networks: Algorithms, Applications and Programming Techniques
Leave, C. (1992) · Journal of the Operational Research Society · doi:10.1057/jors.1992.170 · Cited by 1,283
Adapted wavelet analysis from theory to software
Wickerhauser, M. V. (1994) · CERN Document Server (European Organization for Nuclear Research) · Cited by 1,204
Jähne, B. (1993) · Springer eBooks · doi:10.1007/978-3-662-21817-4 · Cited by 1,139
Neural Networks: Algorithms, Applications and Programming Techniques.
Leave, C., Freeman, J. A., & Skapura, D. M. (1992) · The Journal of the Operational Research Society · doi:10.2307/2584109 · Cited by 924
Ten- to Fourteen-Year Effect of Screening on Breast Cancer Mortality 2
(1982) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/69.2.349 · Cited by 840
CHAN, H.-P., DOI, K., VYBRONY, C. J., SCHMIDT, R. A., METZ, C. E., LAM, K. L., OGURA, T., WU, Y., & MACMAHON, H. (1990) · Investigative Radiology · doi:10.1097/00004424-199010000-00006 · Cited by 359
Chan, H.-P., Doi, K., Galhotra, S., Vyborny, C. J., MacMahon, H., & Jokich, P. M. (1987) · Medical Physics · doi:10.1118/1.596065 · Cited by 342
Wavelet transforms for detecting microcalcifications in mammograms
Strickland, R. N., & Hahn, H. I. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.491423 · Cited by 336
Kittler, J. (1978) · Pattern Recognition and Signal Processing · doi:10.1007/978-94-009-9941-1_3 · Cited by 218
A novel approach to microcalcification detection using fuzzy logic technique
Cheng, H.-D., Lui, Y. M., & Freimanis, R. I. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.712133 · Cited by 208
Analysis of mammographic microcalcifications using gray-level image structure features
Dhawan, A. P., Chitre, Y. S., & Bonasso, C. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.500063 · Cited by 186
Scale-space signatures for the detection of clustered microcalcifications in digital mammograms
Netsch, T., & Peitgen, H. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.802755 · Cited by 137
Zheng, B., Qian, W., & Clarke, L. P. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.538936 · Cited by 97
Using neural networks to select wavelet features for breast cancer diagnosis
Kocur, C. M., Rogers, S. K., Myers, L. R., Burns, T., Kabrisky, M., Hoffmeister, J. W., Bauer, K. W., & Steppe, J. M. (1996) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.499766 · Cited by 48
Automation in mammography: computer vision and human perception
Astley, S., Hutt, I., Adamson, S., Miller, P., Rose, P., Boggis, C. R. M., Taylor, C., Valentine, T., Davies, J. D., & Armstrong, J. (1993) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.148683 · Cited by 32
Wavelet transforms for detecting microcalcifications in mammography
Strickland, R. N., & Hahn, H. I. (2002) · Proceedings - International Conference on Image Processing · doi:10.1109/icip.1994.413344 · Cited by 24
Recognition of clustered microcalcifications using a random field model
Karssemeijer, N. (1993) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.148689 · Cited by 23
Cited by
Computer-Aided Detection and Diagnosis of Breast Cancer With Mammography: Recent Advances
Tang, J., Rangayyan, R. M., Xu, J., El Naqa, I., & Yang, Y. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2008.2009441 · Cited by 619
A support vector machine approach for detection of microcalcifications
El-Naqa, I., Yang, Y., Wernick, M. N., Galatsanos, N. P., & Nishikawa, R. M. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.806569 · Cited by 571
Computer-aided detection and classification of microcalcifications in mammograms: a survey
Cheng, H. D., Cai, X., Chen, X., Hu, L., & Lou, X. (2003) · Pattern Recognition · doi:10.1016/s0031-3203(03)00192-4 · Cited by 563
Exploring feature-based approaches in PET images for predicting cancer treatment outcomes
El Naqa, I., Grigsby, P. W., Apte, A., Kidd, E., Donnelly, E., Khullar, D., Chaudhari, S., Yang, D., Schmitt, M., Laforest, R., et al. (2009) · Pattern Recognition · doi:10.1016/j.patcog.2008.08.011 · Cited by 480
A review of computer-aided diagnosis of breast cancer: Toward the detection of subtle signs
Rangayyan, R. M., Ayres, F. J., & Leo Desautels, J. E. (2007) · Journal of the Franklin Institute · doi:10.1016/j.jfranklin.2006.09.003 · Cited by 337
Metadata
- Authors
- Yu, S., & Guan, L.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2000
- Volume
- 19
- Issue
- 2
- Pages
- 115-126
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2099105076
- Cited by
- 324
- References
- 26
- FWCI
- 14.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.