The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Locating blood vessels in retinal images by piecewise threshold probing of a matched filter response
Abstract
We describe an automated method to locate and outline blood vessels in images of the ocular fundus. Such a tool should prove useful to eye care specialists for purposes of patient screening, treatment evaluation, and clinical study. Our method differs from previously known methods in that it uses local and global vessel features cooperatively to segment the vessel network. We evaluate our method using hand-labeled ground truth segmentations of 20 images. A plot of the operating characteristic shows that our method reduces false positives by as much as 15 times over basic thresholding of a matched filter response (MFR), at up to a 75% true positive rate. For a baseline, we also compared the ground truth against a second hand-labeling, yielding a 90% true positive and a 4% false positive detection rate, on average. These numbers suggest there is still room for a 15% true positive rate improvement, with the same false positive rate, over our method. We are making all our images and hand labelings publicly available for interested researchers to use in evaluating related methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Detection of blood vessels in retinal images using two-dimensional matched filters
Chaudhuri, S., Chatterjee, S., Katz, N., Nelson, M., & Goldbaum, M. (1989) · IEEE Transactions on Medical Imaging · doi:10.1109/42.34715 · Cited by 1,668
Self-citationJähne, B. (1991) · Springer eBooks · doi:10.1007/978-3-662-11565-7 · Cited by 1,222
An experimental comparison of range image segmentation algorithms
Hoover, A., Jean-Baptiste, G., Jiang, X., Flynn, P. J., Bunke, H., Goldgof, D. B., Bowyer, K., Eggert, D. W., Fitzgibbon, A., & Fisher, R. B. (1996) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.506791 · Cited by 790
Self-citationA fuzzy vessel tracking algorithm for retinal images based on fuzzy clustering
Tolias, Y. A., & Panas, S. M. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.700738 · Cited by 365
Fischler, M. A., Tenenbaum, J. M., & Wolf, H. C. (1981) · Computer Graphics and Image Processing · doi:10.1016/0146-664x(81)90056-3 · Cited by 354
Pinz, A., Bernogger, S., Datlinger, P., & Kruger, A. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.730405 · Cited by 233
Empirical evaluation techniques in computer vision
Bowyer, K. W., & Phillips, P. J. (1998) · Medical Entomology and Zoology · Cited by 184
Back-propagation network and its configuration for blood vessel detection in angiograms
Nekovei, R., & Sun, Y. (1995) · IEEE Transactions on Neural Networks · doi:10.1109/72.363449 · Cited by 159
Object-based 3-D reconstruction of arterial trees from magnetic resonance angiograms
Fessler, J. A., & Macovski, A. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.75608 · Cited by 60
Cited by
Identifying Medical Diagnoses and Treatable Diseases by Image-Based Deep Learning
Kermany, D. S., Goldbaum, M., Cai, W., Valentim, C. C. S., Liang, H., Baxter, S. L., McKeown, A., Yang, G., Wu, X., Yan, F., et al. (2018) · Cell · doi:10.1016/j.cell.2018.02.010 · Cited by 4,842
Self-citationRidge-based vessel segmentation in color images of the retina
Staal, J., Abramoff, M. D., Niemeijer, M., Viergever, M. A., & van Ginneken, B. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.825627 · Cited by 4,202
U-Net and Its Variants for Medical Image Segmentation: A Review of Theory and Applications
Siddique, N., Paheding, S., Elkin, C. P., & Devabhaktuni, V. (2021) · IEEE Access · doi:10.1109/access.2021.3086020 · Cited by 1,960
Retinal vessel segmentation using the 2-D Gabor wavelet and supervised classification
Soares, J. V. B., Leandro, J. J. G., Cesar, R. M., Jelinek, H. F., & Cree, M. J. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.879967 · Cited by 1,497
Retinal Imaging and Image Analysis
Abramoff, M. D., Garvin, M. K., & Sonka, M. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2084567 · Cited by 1,439
Metadata
- Authors
- Hoover, A. D., Kouznetsova, V., & Goldbaum, M.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2000-03
- Volume
- 19
- Issue
- 3
- Pages
- 203-210
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2145305441
- Cited by
- 2,582
- References
- 9
- FWCI
- 9.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.