The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Pulsewidth modulation for electronic power conversion
Abstract
The efficient and fast control of electric power forms part of the key technologies of modern automated production. It is performed using electronic power converters. The converters transfer energy from a source to a controlled process in a quantized fashion, using semiconductor switches which are turned on and off at fast repetition rates. The algorithms which generate the switching functions-pulsewidth-modulation techniques-are manifold. They range from simple averaging schemes to involved methods of real-time optimization. This paper gives an overview.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A New Quick-Response and High-Efficiency Control Strategy of an Induction Motor
Takahashi, I., & Noguchi, T. (1986) · IEEE Transactions on Industry Applications · doi:10.1109/tia.1986.4504799 · Cited by 3,407
Leonhard, W. (1996) · Springer eBooks · doi:10.1007/978-3-642-97646-9 · Cited by 2,488
Patel, H. S., & Hoft, R. G. (1973) · IEEE Transactions on Industry Applications · doi:10.1109/tia.1973.349908 · Cited by 1,221
Influence of the modulation method on the conduction and switching losses of a PWM converter system
Kolar, J. W., Ertl, H., & Zach, F. C. (1991) · IEEE Transactions on Industry Applications · doi:10.1109/28.108456 · Cited by 548
Bose, B. K. (1990) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.103436 · Cited by 535
On continuous control of PWM inverters in the overmodulation range including the six-step mode
Holtz, J., Lotzkat, W., & Khambadkone, A. (2003) · Proceedings of the 1992 International Conference on Industrial Electronics, Control, Instrumentation, and Automation · doi:10.1109/iecon.1992.254615 · Cited by 364
Self-citationAcoustic noise reduction in sinusoidal PWM drives using a randomly modulated carrier
Habetler, T. G., & Divan, D. M. (1991) · IEEE Transactions on Power Electronics · doi:10.1109/63.85902 · Cited by 296
Design and Experimental Results of a Brushless AC Servo Drive
Pfaff, G., Weschta, A., & Wick, A. F. (1984) · IEEE Transactions on Industry Applications · doi:10.1109/tia.1984.4504491 · Cited by 244
Kolar, J. W. (1989) · Medical Entomology and Zoology · Cited by 95
Cited by
Multilevel Voltage-Source-Converter Topologies for Industrial Medium-Voltage Drives
Rodriguez, J., Bernet, S., Wu, B., Pontt, J. O., & Kouro, S. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.907044 · Cited by 2,385
Current control techniques for three-phase voltage-source PWM converters: a survey
Kazmierkowski, M. P., & Malesani, L. (1998) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.720325 · Cited by 2,125
The age of multilevel converters arrives
Franquelo, L., Rodriguez, J., Leon, J., Kouro, S., Portillo, R., & Prats, M. (2008) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2008.923519 · Cited by 2,016
Model Predictive Control—A Simple and Powerful Method to Control Power Converters
Kouro, S., Cortes, P., Vargas, R., Ammann, U., & Rodriguez, J. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2008349 · Cited by 1,975
Predictive Current Control of a Voltage Source Inverter
Rodriguez, J., Pontt, J., Silva, C. A., Correa, P., Lezana, P., Cortes, P., & Ammann, U. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.888802 · Cited by 1,563
Abu-Rub, H., Holtz, J., Rodriguez, J., & Baoming, G. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2043039 · Cited by 1,337
Self-citationPower-Synchronization Control of Grid-Connected Voltage-Source Converters
Zhang, L., Harnefors, L., & Nee, H.-P. (2010) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2009.2032231 · Cited by 1,317
Multilevel Converters: An Enabling Technology for High-Power Applications
Rodriguez, J., Franquelo, L. G., Kouro, S., Leon, J. I., Portillo, R. C., Prats, M. A. M., & Perez, M. A. (2009) · Proceedings of the IEEE · doi:10.1109/jproc.2009.2030235 · Cited by 1,196
Zhou, K., & Wang, D. (2002) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.982262 · Cited by 1,019
Detailed and Averaged Models for a 401-Level MMC–HVDC System
Peralta, J., Saad, H., Dennetiere, S., Mahseredjian, J., & Nguefeu, S. (2012) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2012.2188911 · Cited by 623
Model Predictive Control of Power Electronic Systems: Methods, Results, and Challenges
Karamanakos, P., Liegmann, E., Geyer, T., & Kennel, R. (2020) · IEEE Open Journal of Industry Applications · doi:10.1109/ojia.2020.3020184 · Cited by 491
Leon, J. I., Vazquez, S., & Franquelo, L. G. (2017) · Proceedings of the IEEE · doi:10.1109/jproc.2017.2726583 · Cited by 481
Leon, J. I., Kouro, S., Franquelo, L. G., Rodriguez, J., & Wu, B. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2519321 · Cited by 462
Space Vector Based Hybrid PWM Techniques for Reduced Current Ripple
Narayanan, G., Ranganathan, V. T., Zhao, D., Krishnamurthy, H. K., & Ayyanar, R. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.907670 · Cited by 308
A Critical Review of Advanced Electric Machines and Control Strategies for Electric Vehicles
Liu, C., Chau, K. T., Lee, C. H. T., & Song, Z. (2021) · Proceedings of the IEEE · doi:10.1109/jproc.2020.3041417 · Cited by 307
Wang, F., Zhang, Z., Mei, X., Rodríguez, J., & Kennel, R. (2018) · Energies · doi:10.3390/en11010120 · Cited by 298
Hava, A. M., & Ün, E. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2100100 · Cited by 292
FPGA-Based Current Controllers for AC Machine Drives—A Review
Naouar, M.-W., Monmasson, E., Naassani, A. A., Slama-Belkhodja, I., & Patin, N. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.898302 · Cited by 261
Nahin, N. I., Nafis, M., Prokash Biswas, S., Kamal Hosain, M., Das, P., & Haq, S. (2022) · Heliyon · doi:10.1016/j.heliyon.2022.e11733 · Cited by 18
Metadata
- Authors
- Holtz, J.
- Venue
- Proceedings of the IEEE
- Published
- 1994
- Volume
- 82
- Issue
- 8
- Pages
- 1194-1214
- ISSN
- 0018-9219 (ISSN-L)
- OpenAlex
- W2135535457
- Cited by
- 1,117
- References
- 9
- FWCI
- 4.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.