Independent component analysis for EEG source localization
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
We consider a spatiotemporal method for source localization, taking advantage of the entire EEG time series to reduce the configuration space we must evaluate. The EEG data are first decomposed into signal and noise subspaces using a principal component analysis (PCA) decomposition. This partitioning allows us to easily discard the noise subspace, which has two primary benefits: the remaining signal is less noisy, and it has lower dimensionality. After PCA, we apply independent component analysis (ICA) on the signal subspace. The ICA algorithm separates multichannel data into activation maps due to temporally independent stationary sources. For each activation map we perform an EEG source localization procedure, looking only for a single dipole per map. By localizing multiple dipoles independently, we substantially reduce our search complexity and increase the likelihood of efficiently converging on the correct solution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Information-Maximization Approach to Blind Separation and Blind Deconvolution
Bell, A. J., & Sejnowski, T. J. (1995) · Neural Computation · doi:10.1162/neco.1995.7.6.1129 · Cited by 8,986
Pascual-Marqui, R. D., Michel, C. M., & Lehmann, D. (1994) · International Journal of Psychophysiology · doi:10.1016/0167-8760(84)90014-x · Cited by 2,869
Multiple dipole modeling and localization from spatio-temporal MEG data
Mosher, J. C., Lewis, P. S., & Leahy, R. M. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.141192 · Cited by 1,048
Neuromagnetic source imaging with FOCUSS: a recursive weighted minimum norm algorithm
Gorodnitsky, I. F., George, J. S., & Rao, B. D. (1995) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(95)00107-a · Cited by 567
Source localization using recursively applied and projected (RAP) MUSIC
Mosher, J. C., & Leahy, R. M. (1999) · IEEE Transactions on Signal Processing · doi:10.1109/78.740118 · Cited by 398
Finite-element model of the human head: scalp potentials due to dipole sources
Yan, Y., Nunez, P. L., & Hart, R. T. (1991) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442317 · Cited by 208
Cited by
Delorme, A., Sejnowski, T., & Makeig, S. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.11.004 · Cited by 1,759
“…for separating distinct artifactual processes including eye blink, muscle and electrical artifacts (Barbati et al., 2004; Delorme et al., 2001; Iriarte et al., 2003; James and Gibson, 2003; Joyce et al., 2004; Jung et al., 2000b; Tran et al., 2004; Urrestarazu et al., 2004; Zhukov et al., 2000).”
BackgroundMethodResultInfluentialReview on solving the inverse problem in EEG source analysis
Grech, R., Cassar, T., Muscat, J., Camilleri, K. P., Fabri, S. G., Zervakis, M., Xanthopoulos, P., Sakkalis, V., & Vanrumste, B. (2008) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-5-25 · Cited by 1,193
Imaging brain dynamics using independent component analysis
Jung, T.-P., Makeig, S., McKeown, M. J., Bell, A. J., Lee, T.-W., & Sejnowski, T. J. (2001) · Proceedings of the IEEE · doi:10.1109/5.939827 · Cited by 592
Review on solving the forward problem in EEG source analysis
Hallez, H., Vanrumste, B., Grech, R., Muscat, J., De Clercq, W., Vergult, A., D'Asseler, Y., Camilleri, K. P., Fabri, S. G., Van Huffel, S., et al. (2007) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-4-46 · Cited by 527
Ghosh-Dastidar, S., Adeli, H., & Dadmehr, N. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.905490 · Cited by 466
EEG-based workers' stress recognition at construction sites
Jebelli, H., Hwang, S., & Lee, S. (2018) · Automation in Construction · doi:10.1016/j.autcon.2018.05.027 · Cited by 339
Emotion recognition using brain activity
Horlings, R., Datcu, D., & Rothkrantz, L. J. M. (2008) · Proceedings of the 9th International Conference on Computer Systems and Technologies and Workshop for PhD Students in Computing - CompSysTech '08 · doi:10.1145/1500879.1500888 · Cited by 262
A survey of methods used for source localization using EEG signals
Jatoi, M. A., Kamel, N., Malik, A. S., Faye, I., & Begum, T. (2014) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2014.01.009 · Cited by 177
Ossadtchi, A., Baillet, S., Mosher, J. C., Thyerlei, D., Sutherling, W., & Leahy, R. M. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2003.10.036 · Cited by 104
Metadata
- Authors
- Zhukov, L., Weinstein, D., & Johnson, C.
- Venue
- IEEE Engineering in Medicine and Biology Magazine
- Published
- 2000
- Volume
- 19
- Issue
- 3
- Pages
- 87-96
- ISSN
- 0739-5175 (ISSN-L)
- OpenAlex
- W2158947615
- Cited by
- 133
- References
- 6
- FWCI
- 2.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.