CoChat

Improving detection of muscle activation intervals

Micera, S., Vannozzi, G., Sabatini, A.M., Dario, P. · 2001 · IEEE Engineering in Medicine and Biology Magazine
Cited by 97

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

In this article the characteristics of traditional and novel algorithms for the detection of the onset (and offset) of muscle contraction using EMG signals have been briefly summarized. As is evident from these descriptions, many studies have been carried out in the last few years in order to improve the accuracy of the detection and to make the performance of the algorithm less dependent on the skill of the operator.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/51.982274

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Research works printed but not linked: 35

  1. 10.1123/jab.13.2.135 · DOI · Paper page
  2. 10.1109/10.52324 · DOI · Paper page
  3. 10.1109/86.736154 · DOI · Paper page
  4. 10.1109/10.32103 · DOI · Paper page
  5. Saxena, 1995, An EMG-controlled grasping system for tetraplegics, J. Rehab. Res. Develop., 32, 17
  6. 10.1109/10.1370 · DOI · Paper page
  7. 10.1016/1350-4533(96)00006-9 · DOI · Paper page
  8. 10.2106/00004623-198264090-00008 · DOI · Paper page
  9. 10.1111/j.1469-8749.1987.tb02131.x · doi:10.1111/j.1469-8749.1987.tb02131.x
  10. 10.2106/00004623-197759040-00021 · doi:10.2106/00004623-197759040-00021
  11. 10.1111/j.1469-8749.1987.tb02130.x · doi:10.1111/j.1469-8749.1987.tb02130.x
  12. 10.2106/00004623-198062030-00004 · DOI · Paper page
  13. 10.1007/BF00250604 · DOI
  14. 10.1136/jnnp.58.3.326 · DOI · Paper page
  15. 10.1007/bf00238956 · DOI · Paper page
  16. 10.1007/BF00235977 · DOI · Paper page
  17. 10.1007/BF00243226 · DOI · Paper page
  18. 10.1136/jnnp.49.12.1378 · DOI
  19. 10.1016/0013-4694(78)90205-5 · DOI
  20. 10.1016/0304-3940(83)90291-4 · DOI
  21. 10.1093/ptj/64.12.1813 · DOI · Paper page
  22. 10.1016/S0013-4694(96)95190-5 · DOI · Paper page
  23. 10.1111/j.1532-5415.1991.tb01642.x · DOI · Paper page
  24. 10.1093/ptj/74.1.17 · DOI · Paper page
  25. 10.1097/00007632-199305000-00005 · DOI
  26. Greenisen, 1979, Computerised interpretation of initiation and relaxation of EMG recorded dynamic muscle contraction, 171
  27. Bogey, 1992, Computer algorithms to characterize individual subject EMG profiles during gait, Arch. Phys. Med. Rehab., 73, 835
  28. 10.1016/S1047-9651(18)30504-7 · doi:10.1016/s1047-9651(18)30504-7
  29. 10.1016/0013-4694(78)90017-2 · DOI · Paper page
  30. 10.1109/10.661154 · DOI · Paper page
  31. 10.1109/86.769404 · DOI
  32. 10.1002/0471221082 · DOI · Paper page
  33. 10.1109/TAC.1976.1101146 · DOI · Paper page
  34. 10.1007/978-1-4757-1862-1 · DOI · Paper page
  35. 10.1109/10.488803 · DOI

Cited by

See all 97

Metadata

Authors
Micera, S., Vannozzi, G., Sabatini, A. M., & Dario, P.
Venue
IEEE Engineering in Medicine and Biology Magazine
Published
2001
Volume
20
Issue
6
Pages
38-46
ISSN
0739-5175 (ISSN-L)
OpenAlex
W2066725876
Cited by
97
References
7
FWCI
2.77
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Improving detection of muscle activation intervals. https://app.cochat.ai/papers/10.1109/51.982274
The paper
Micera, S., Vannozzi, G., Sabatini, A. M., & Dario, P. (2001). Improving detection of muscle activation intervals. IEEE Engineering in Medicine and Biology Magazine. https://doi.org/10.1109/51.982274

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.