Improving detection of muscle activation intervals
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In this article the characteristics of traditional and novel algorithms for the detection of the onset (and offset) of muscle contraction using EMG signals have been briefly summarized. As is evident from these descriptions, many studies have been carried out in the last few years in order to improve the accuracy of the detection and to make the performance of the algorithm less dependent on the skill of the operator.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149
EMG feature evaluation for movement control of upper extremity prostheses
Zardoshti-Kermani, M., Wheeler, B. C., Badie, K., & Hashemi, R. M. (1995) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.481972 · Cited by 477
Functional Separation of EMG Signals via ARMA Identification Methods for Prosthesis Control Purposes
Graupe, D., & Cline, W. K. (1975) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1975.5408479 · Cited by 354
The development of mature gait
Sutherland, D. (1997) · Gait & Posture · doi:10.1016/s0966-6362(97)00029-5 · Cited by 351
Graupe, D., Salahi, J., & Kohn, K. H. (1982) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(82)90021-8 · Cited by 205
Micera, S., Sabatini, A. M., Dario, P., & Rossi, B. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00055-7 · Cited by 90
Self-citationDi Fabio, R. P., Badke, M. B., & Duncan, P. W. (1986) · Brain Research · doi:10.1016/0006-8993(86)91010-3 · Cited by 85
Research works printed but not linked: 35
- 10.1123/jab.13.2.135 · DOI · Paper page
- 10.1109/10.52324 · DOI · Paper page
- 10.1109/86.736154 · DOI · Paper page
- 10.1109/10.32103 · DOI · Paper page
- Saxena, 1995, An EMG-controlled grasping system for tetraplegics, J. Rehab. Res. Develop., 32, 17
- 10.1109/10.1370 · DOI · Paper page
- 10.1016/1350-4533(96)00006-9 · DOI · Paper page
- 10.2106/00004623-198264090-00008 · DOI · Paper page
- 10.1111/j.1469-8749.1987.tb02131.x · doi:10.1111/j.1469-8749.1987.tb02131.x
- 10.2106/00004623-197759040-00021 · doi:10.2106/00004623-197759040-00021
- 10.1111/j.1469-8749.1987.tb02130.x · doi:10.1111/j.1469-8749.1987.tb02130.x
- 10.2106/00004623-198062030-00004 · DOI · Paper page
- 10.1007/BF00250604 · DOI
- 10.1136/jnnp.58.3.326 · DOI · Paper page
- 10.1007/bf00238956 · DOI · Paper page
- 10.1007/BF00235977 · DOI · Paper page
- 10.1007/BF00243226 · DOI · Paper page
- 10.1136/jnnp.49.12.1378 · DOI
- 10.1016/0013-4694(78)90205-5 · DOI
- 10.1016/0304-3940(83)90291-4 · DOI
- 10.1093/ptj/64.12.1813 · DOI · Paper page
- 10.1016/S0013-4694(96)95190-5 · DOI · Paper page
- 10.1111/j.1532-5415.1991.tb01642.x · DOI · Paper page
- 10.1093/ptj/74.1.17 · DOI · Paper page
- 10.1097/00007632-199305000-00005 · DOI
- Greenisen, 1979, Computerised interpretation of initiation and relaxation of EMG recorded dynamic muscle contraction, 171
- Bogey, 1992, Computer algorithms to characterize individual subject EMG profiles during gait, Arch. Phys. Med. Rehab., 73, 835
- 10.1016/S1047-9651(18)30504-7 · doi:10.1016/s1047-9651(18)30504-7
- 10.1016/0013-4694(78)90017-2 · DOI · Paper page
- 10.1109/10.661154 · DOI · Paper page
- 10.1109/86.769404 · DOI
- 10.1002/0471221082 · DOI · Paper page
- 10.1109/TAC.1976.1101146 · DOI · Paper page
- 10.1007/978-1-4757-1862-1 · DOI · Paper page
- 10.1109/10.488803 · DOI
Cited by
Techniques of EMG signal analysis: detection, processing, classification and applications
Reaz, M. B. I., Hussain, M. S., & Mohd-Yasin, F. (2006) · Biological Procedures Online · doi:10.1251/bpo115 · Cited by 1,629
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845
Self-citationControl of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal
Zecca, M., Micera, S., Carrozza, M. C., & Dario, P. (2017) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v45.i1-6.150 · Cited by 570
Self-citationA heuristic fuzzy logic approach to EMG pattern recognition for multifunctional prosthesis control
Ajiboye, A. B., & Weir, R. F. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.847357 · Cited by 415
“Onset for each contraction was automatically determined as the point when the active rms signal was greater than the rms quiescent signal mean plus three standard deviations [24].”
BackgroundZhang, X., & Zhou, P. (2012) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2012.06.005 · Cited by 218
“Another approach that applies some statistical criteria such as generalized likelihood ratio (GLR) and its modifications [15], [16], [19] was also developed to determine onset time of muscle activity.”
Background
Metadata
- Authors
- Micera, S., Vannozzi, G., Sabatini, A. M., & Dario, P.
- Venue
- IEEE Engineering in Medicine and Biology Magazine
- Published
- 2001
- Volume
- 20
- Issue
- 6
- Pages
- 38-46
- ISSN
- 0739-5175 (ISSN-L)
- OpenAlex
- W2066725876
- Cited by
- 97
- References
- 7
- FWCI
- 2.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Improving detection of muscle activation intervals. https://app.cochat.ai/papers/10.1109/51.982274
- The paper
- Micera, S., Vannozzi, G., Sabatini, A. M., & Dario, P. (2001). Improving detection of muscle activation intervals. IEEE Engineering in Medicine and Biology Magazine. https://doi.org/10.1109/51.982274
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.