The DOI matches its Crossref record; 58 of the 58 references it cites were found in a registry or an index.
Current time-domain methods for assessing tissue motion by analysis from reflected ultrasound echoes-a review
Abstract
The Doppler technique has traditionally been the method used to extract motion information from ultrasonic echoes reflected by moving tissues. The Doppler technique has been around for a long time, and has been extensively reviewed and analyzed in the literature. Recently, time-domain methodologies for estimating tissue motion have gained in popularity. Time-domain methods have advantages over Doppler methods in many applications, and as of yet have not been comprehensively reviewed. An overview of time-domain techniques that have appeared in the literature over the past few years is presented. Their potential advantages over Doppler are examined, and the individual techniques are compared.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Horn, B. K. P., & Schunck, B. G. (1981) · Artificial Intelligence · doi:10.1016/0004-3702(81)90024-2 · Cited by 10,312
Horn, B. K., & Schunck, B. G. (1981) · SPIE Proceedings · doi:10.1117/12.965761 · Cited by 7,394
Elastography: A quantitative method for imaging the elasticity of biological tissues
Ophir, J. (1991) · Ultrasonic Imaging · doi:10.1016/0161-7346(91)90079-w · Cited by 3,776
Perception of the Visual World
(1952) · Archives of Ophthalmology · doi:10.1001/archopht.1952.01700030123016 · Cited by 3,732
Digital Imaging Techniques In Experimental Stress Analysis
Peters, W. H., & Ranson, W. F. (1982) · Optical Engineering · doi:10.1117/12.7972925 · Cited by 1,884
Displacement Measurement and Its Application in Interframe Image Coding
Jain, J., & Jain, A. (1981) · IEEE Transactions on Communications · doi:10.1109/tcom.1981.1094950 · Cited by 1,598
MOTION COMPENSATED INTER-FRAME CODING FOR VIDEO CONFERENCING
Koga, T. (1981) · Medical Entomology and Zoology · Cited by 1,580
Statistics of Speckle in Ultrasound B-Scans
Wagner, R. F., Smith, S. W., Sandrik, J. M., & Lopez, H. (1983) · IEEE Transactions on Sonics and Ultrasonics · doi:10.1109/t-su.1983.31404 · Cited by 1,398
Probability and Information Theory with Applications to Radar
(1953) · Elsevier eBooks · doi:10.1016/c2013-0-05390-x · Cited by 1,283
The Perception of the Visual World.
S., H. W., & Gibson, J. J. (1951) · The Journal of Philosophy · doi:10.2307/2021210 · Cited by 1,139
Cited by
Biomedical photoacoustic imaging
Beard, P. (2011) · Interface Focus · doi:10.1098/rsfs.2011.0028 · Cited by 2,205
Split-spectrum amplitude-decorrelation angiography with optical coherence tomography
Jia, Y., Tan, O., Tokayer, J., Potsaid, B., Wang, Y., Liu, J. J., Kraus, M. F., Subhash, H., Fujimoto, J. G., Hornegger, J., et al. (2012) · Optics Express · doi:10.1364/oe.20.004710 · Cited by 1,841
D'hooge, J. (2000) · European Journal of Echocardiography · doi:10.1053/euje.2000.0031 · Cited by 990
Global longitudinal strain: a novel index of left ventricular systolic function
Reisner, S. A., Lysyansky, P., Agmon, Y., Mutlak, D., Lessick, J., & Friedman, Z. (2004) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2004.02.011 · Cited by 735
Advances in ultrasound biomicroscopy
Foster, F. S., Pavlin, C. J., Harasiewicz, K. A., Christopher, D. A., & Turnbull, D. H. (2000) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(99)00096-4 · Cited by 719
Loupas, T., Powers, J. T., & Gill, R. W. (1995) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.393110 · Cited by 560
Konofagou, E., & Ophir, J. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00109-4 · Cited by 444
Two-dimensional temperature estimation using diagnostic ultrasound
Simon, C., VanBaren, P., & Ebbini, E. S. (1998) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.710592 · Cited by 433
Ultrafast compound imaging for 2-D motion vector estimation: application to transient elastography
Tanter, M., Bercoff, J., Sandrin, L., & Fink, M. (2002) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2002.1041078 · Cited by 414
Rapid tracking of small displacements with ultrasound
Pinton, G. F., Dahl, J. J., & Trahey, G. E. (2006) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2006.1642509 · Cited by 389
Korinek, J., Wang, J., Sengupta, P. P., Miyazaki, C., Kjaergaard, J., McMahon, E., Abraham, T. P., & Belohlavek, M. (2005) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2005.03.024 · Cited by 349
Vianna-Pinton, R., Moreno, C. A., Baxter, C. M., Lee, K. S., Tsang, T. S. M., & Appleton, C. P. (2009) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2008.12.017 · Cited by 338
Tissue elasticity reconstruction using linear perturbation method
Kallel, F., & Bertrand, M. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.500139 · Cited by 329
Model-based estimation of ultrasonic echoes. Part I: Analysis and algorithms
Demirli, R., & Saniie, J. (2001) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.920713 · Cited by 306
Spatio-temporal nonrigid registration for ultrasound cardiac motion estimation
Ledesma-Carbayo, M. J., Kybic, J., Desco, M., Santos, A., Suhling, M., Hunziker, P., & Unser, M. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.852050 · Cited by 290
Elastography: Ultrasonic imaging of tissue strain and elastic modulus in vivo
Ophir, J., Cespedes, I., Garra, B., Ponnekanti, H., Huang, Y., & Maklad, N. (1996) · European Journal of Ultrasound · doi:10.1016/0929-8266(95)00134-4 · Cited by 287
Myocardial elastography—a feasibility study in vivo
Konofagou, E. E., D’hooge, J., & Ophir, J. (2002) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(02)00488-x · Cited by 264
Routh, H. F. (1996) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.544510 · Cited by 63
Acoustic resolution photoacoustic Doppler velocimetry in blood-mimicking fluids
Brunker, J., & Beard, P. (2016) · Scientific Reports · doi:10.1038/srep20902 · Cited by 32
An Angle-Independent Cross-Sectional Doppler Method for Flow Estimation in the Common Carotid Artery
van Knippenberg, L., van Sloun, R. J. G., Shulepov, S., Bouwman, R. A., & Mischi, M. (2020) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2020.2975315 · Cited by 11
Tong, Y., Zhao, H., Fang, H., Zhao, Y., & Yuan, X. (2016) · AIP Advances · doi:10.1063/1.4942097 · Cited by 4
Metadata
- Authors
- Hein, I. A., & O'Brien, W. D.
- Venue
- IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control
- Published
- 1993-03
- Volume
- 40
- Issue
- 2
- Pages
- 84-102
- ISSN
- 0885-3010 (ISSN-L)
- OpenAlex
- W2149275333
- Cited by
- 309
- References
- 58
- FWCI
- 12.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.