The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Synthetic aperture imaging for small scale systems
Abstract
Multi-element synthetic aperture imaging methods suitable for applications with severe cost and size limitations are explored. Array apertures are synthesized using an active multi-element receive subaperture and a multi-element transmit subaperture defocused to emulate a single-element spatial response with high acoustic power. Echo signals are recorded independently by individual elements of the receive subaperture. Each method uses different spatial frequencies and acquisition strategies for imaging, and therefore different sets of active transmit/receive element combinations. Following acquisition, image points are reconstructed using the complete data set with full dynamic focus on both transmit and receive. Various factors affecting image quality have been evaluated and compared to conventional imagers through measurements with a 3.5 MHz, 128-element transducer array on different gel phantoms. Multielement synthetic aperture methods achieve higher electronic signal to noise ratio and better contrast resolution than conventional synthetic aperture techniques, approaching conventional phased array performance.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Flax, S. W., & O’Donnell, M. (1988) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.9333 · Cited by 483
Self-citationA novel method for angle independent ultrasonic imaging of blood flow and tissue motion
Bohs, L. N., & Trahey, G. E. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.133210 · Cited by 438
(1993) · NDT & E International · doi:10.1016/0963-8695(93)90667-j · Cited by 395
Ultrasonic texture motion analysis: theory and simulation
Meunier, J., & Bertrand, M. (1995) · IEEE Transactions on Medical Imaging · doi:10.1109/42.387711 · Cited by 191
Digital beamforming in ultrasound
Steinberg, B. D. (1992) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.165556 · Cited by 148
VLSI circuits for adaptive digital beamforming in ultrasound imaging
Karaman, M., Atalar, A., & Köymen, H. (1993) · IEEE Transactions on Medical Imaging · doi:10.1109/42.251122 · Cited by 41
Self-citation
Cited by
Ultrafast imaging in biomedical ultrasound
Tanter, M., & Fink, M. (2014) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2014.2882 · Cited by 1,151
Evolution of ultrasound beamformers
Thomenius, K. E. (2002) · 1996 IEEE Ultrasonics Symposium. Proceedings · doi:10.1109/ultsym.1996.584398 · Cited by 325
Single-chip CMUT-on-CMOS front-end system for real-time volumetric IVUS and ICE imaging
Gurun, G., Tekes, C., Zahorian, J., Xu, T., Satir, S., Karaman, M., Hasler, J., & Degertekin, F. L. (2014) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2014.6722610 · Cited by 176
“where μb is mean intensity in decibels of the bright spot of the chicken heart image, μs and σs are the mean and standard deviation of the intensity in decibels within the speckle [32].”
BackgroundMethodSelf-citation
Metadata
- Authors
- Karaman, M., Li, P.-C., & O'Donnell, M.
- Venue
- IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control
- Published
- 1995-05
- Volume
- 42
- Issue
- 3
- Pages
- 429-442
- ISSN
- 0885-3010 (ISSN-L)
- OpenAlex
- W2118434273
- Cited by
- 575
- References
- 6
- FWCI
- 3.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.