The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Shear elasticity probe for soft tissues with 1-D transient elastography
Abstract
Important tissue parameters such as elasticity can be deduced from the study of the propagation of low frequency shear waves. A new method for measuring the shear velocity in soft tissues is presented in this paper. Unlike conventional transient elastography, in which the ultrasonic transducer and the low frequency vibrator are two separated parts, the new method relies on a probe that associates the vibrator and the transducer, which is built on the axis of the vibrator. This setup is easy to use. The low frequency shear wave is driven by the transducer itself that acts as a piston while it is used in pulse echo mode to acquire ultrasonic lines. The results obtained with the new method are in good agreement with those obtained with the conventional one.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantitative seismology : theory and methods
Aki, K., & Richards, P. G. (1980) · Cited by 4,410
Elastography: A quantitative method for imaging the elasticity of biological tissues
Ophir, J. (1991) · Ultrasonic Imaging · doi:10.1016/0161-7346(91)90079-w · Cited by 3,776
Quantitative seismology, theory and methods
Nolet, G. (1981) · Earth-Science Reviews · doi:10.1016/0012-8252(81)90044-1 · Cited by 3,578
Magnetic Resonance Elastography by Direct Visualization of Propagating Acoustic Strain Waves
Muthupillai, R., Lomas, D. J., Rossman, P. J., Greenleaf, J. F., Manduca, A., & Ehman, R. L. (1995) · Science · doi:10.1126/science.7569924 · Cited by 2,116
Internal displacement and strain imaging using ultrasonic speckle tracking
O'Donnell, M., Skovoroda, A. R., Shapo, B. M., & Emelianov, S. Y. (1994) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.285465 · Cited by 699
Imaging of the elastic properties of tissue—A review
Gao, L., Parker, K. J., Lerner, R. M., & Levinson, S. F. (1996) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(96)00120-2 · Cited by 514
“Sonoelasticity” images derived from ultrasound signals in mechanically vibrated tissues
Lerner, R. M., Huang, S. R., & Parker, K. J. (1990) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(90)90002-t · Cited by 493
Tissue response to mechanical vibrations for “sonoelasticity imaging”
Parker, K. J., Huang, S. R., Musulin, R. A., & Lerner, R. M. (1990) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(90)90003-u · Cited by 478
Ultrasonic imaging of internal vibration of soft tissue under forced vibration
Yamakoshi, Y., Sato, J., & Sato, T. (1990) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.46969 · Cited by 474
Shear modulus imaging with 2-D transient elastography
Sandrin, L., Tanter, M., Catheline, S., & Fink, M. (2002) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.996560 · Cited by 412
Self-citationKrouskop, T. A., Dougherty, D. R., & Vinson, F. S. (1987) · PubMed · Cited by 362
Biophysical Bases of Elasticity Imaging
Sarvazyan, A. P., Skovoroda, A. R., Emelianov, S. Y., Fowlkes, J. B., Pipe, J. G., Adler, R. S., Buxton, R. B., & Carson, P. L. (1995) · Acoustical Imaging · doi:10.1007/978-1-4615-1943-0_23 · Cited by 301
Elastography: Ultrasonic imaging of tissue strain and elastic modulus in vivo
Ophir, J., Cespedes, I., Garra, B., Ponnekanti, H., Huang, Y., & Maklad, N. (1996) · European Journal of Ultrasound · doi:10.1016/0929-8266(95)00134-4 · Cited by 287
A solution to diffraction biases in sonoelasticity: The acoustic impulse technique
Catheline, S., Wu, F., & Fink, M. (1999) · The Journal of the Acoustical Society of America · doi:10.1121/1.426907 · Cited by 282
Self-citationTime-Resolved Pulsed Elastography with Ultrafast Ultrasonic Imaging
Sandrin, L., Catheline, S., Tanter, M., Hennequin, X., & Fink, M. (1999) · Ultrasonic Imaging · doi:10.1177/016173469902100402 · Cited by 267
Self-citationSonoelastic determination of human skeletal muscle elasticity
Levinson, S. F., Shinagawa, M., & Sato, T. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(94)00173-2 · Cited by 203
An adaptive strain estimator for elastography
Alam, S. K., Ophir, J., & Konofagou, E. E. (1998) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.660156 · Cited by 198
Diffraction field of a low frequency vibrator in soft tissues using transient elastography
Catheline, S., Thomas, J.-L., Wu, F., & Fink, M. A. (1999) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.775668 · Cited by 167
Self-citationWalker, W. F., & Trahey, G. E. (1994) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.308499 · Cited by 113
Chen, J.-F., Fowlkes, J. B., Carson, P. L., & Rubin, J. M. (1997) · International Journal of Imaging Systems and Technology · doi:10.1002/(sici)1098-1098(1997)8:1<89::aid-ima11>3.0.co;2-g · Cited by 103
Sonoelasticity imaging: results in in vitro tissue specimens.
Lee, F., Bronson, J. P., Lerner, R. M., Parker, K. J., Huang, S.-C., & Roach, D. J. (1991) · Radiology · doi:10.1148/radiology.181.1.1887038 · Cited by 50
Acoustic shear wave displacement measurement using ultrasound
Dutt, V., Kinnick, R. R., & Greenleaf, J. F. (2002) · Proceedings/Proceedings - IEEE Ultrasonics Symposium · doi:10.1109/ultsym.1996.584202 · Cited by 25
Cited by
Transient elastography: a new noninvasive method for assessment of hepatic fibrosis
Sandrin, L., Fourquet, B., Hasquenoph, J.-M., Yon, S., Fournier, C., Mal, F., Christidis, C., Ziol, M., Poulet, B., Kazemi, F., et al. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2003.07.001 · Cited by 2,738
Self-citationZiol, M., Handra-Luca, A., Kettaneh, A., Christidis, C., Mal, F., Kazemi, F., de Lédinghen, V., Marcellin, P., Dhumeaux, D., Trinchet, J.-C., et al. (2005) · Hepatology · doi:10.1002/hep.20506 · Cited by 1,470
Diagnosis of cirrhosis by transient elastography (FibroScan): a prospective study
Foucher, J. (2006) · Gut · doi:10.1136/gut.2005.069153 · Cited by 1,284
Bamber, J., Cosgrove, D., Dietrich, C., Fromageau, J., Bojunga, J., Calliada, F., Cantisani, V., Correas, J.-M., D'Onofrio, M., Drakonaki, E., et al. (2013) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/s-0033-1335205 · Cited by 1,198
Self-citationXiao, G., Zhu, S., Xiao, X., Yan, L., Yang, J., & Wu, G. (2017) · Hepatology · doi:10.1002/hep.29302 · Cited by 895
Metadata
- Authors
- Sandrin, L., Tanter, M., Gennisson, J.-L., Catheline, S., & Fink, M.
- Venue
- IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control
- Published
- 2002-04
- Volume
- 49
- Issue
- 4
- Pages
- 436-446
- ISSN
- 0885-3010 (ISSN-L)
- OpenAlex
- W2096995350
- Cited by
- 427
- References
- 22
- FWCI
- 8.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.