High density interconnects and flexible hybrid assemblies for active biomedical implants
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Advanced microtechnologies offer new opportunities for the development of active implants that go beyond the design of pacemakers and cochlea implants. Examples of future implants include neural and muscular stimulators, implantable drug delivery systems, intracorporal monitoring devices and body fluid control systems. The active microimplants demand a high degree of device miniaturization without compromising on design flexibility and biocompatibility requirements. With the need for integrating various microcomponents for a complex retina stimulator device, we have developed a novel technique for microassembly and high-density interconnects employing flexible, ultra-thin polymer based substrates. Pads for interconnections, conductive lines, and microelectrodes were embedded into the polyimide substrate as thin films. Photolithography and sputtering has been employed to pattern the microstructures. The novel "MicroFlex interconnection (MFI)" technology was developed to achieve chip size package (CSP) dimensions without the requirement of using bumped flip chips (FC). The MFI is based on a rivet like approach that yields an electrical and mechanical contact between the pads on the flexible polyimide substrate and the bare chips or electronic components. Center to center bond pad distances smaller than 100 /spl mu/m were accomplished. The ultra thin substrates and the MFI technology was proven to be biocompatible. Electrical and mechanical tests confirmed that interconnects and assembly of bare chips are reliable and durable. Based on our experience with the retina stimulator implant, we defined design rules regarding the flexible substrate, the bond pads, and the embedded conductive tracks. It is concluded that the MFI opens new venues for a novel generation of active implants with advanced sensing, actuation, and signal processing properties.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Polyimides as biomaterials: preliminary biocompatibility testing
Richardson, R. R., Miller, J. A., & Reichert, W. M. (1993) · Biomaterials · doi:10.1016/0142-9612(93)90183-3 · Cited by 302
Stieglitz, T., Beutel, H., & Meyer, J.-U. (1997) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(97)01494-5 · Cited by 125 · cited 1×
“Passive light-weight polymer devices with integrated microelectrodes have been described previously for interfacing regenerating peripheral nerves [ 6 ].”
MethodSelf-citationHistological Reaction to Polyimide Films in the Cochlea
Haggerty, H. S., & Lusted, H. S. (1989) · Acta Oto-Laryngologica · doi:10.3109/00016488909127474 · Cited by 31 · cited 1×
“Inflammatory reactions of Polyimide in cochlea implants were modest, when present [9].”
Background
Cited by
Polymeric Biomaterials for Medical Implants and Devices
Teo, A. J. T., Mishra, A., Park, I., Kim, Y.-J., Park, W.-T., & Yoon, Y.-J. (2016) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.5b00429 · Cited by 778
Subbaroyan, J., Martin, D. C., & Kipke, D. R. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/4/006 · Cited by 368
“While using a ‘soft’ substrate for intracranial applications posing fabrication and insertion challenges, the most effective method is to reduce the tethering force by using flexible interconnects with silicon or polymer substrates [42–46].”
MethodKipke, D. R., Vetter, R. J., Williams, J. C., & Hetke, J. F. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814443 · Cited by 367
State-of-the-art MEMS and microsystem tools for brain research
Seymour, J. P., Wu, F., Wise, K. D., & Yoon, E. (2017) · Microsystems & Nanoengineering · doi:10.1038/micronano.2016.66 · Cited by 216
Flexible, Penetrating Brain Probes Enabled by Advances in Polymer Microfabrication
Weltman, A., Yoo, J., & Meng, E. (2016) · Micromachines · doi:10.3390/mi7100180 · Cited by 184
Metadata
- Authors
- Meyer, J.-U., Stieglitz, T., Scholz, O., Haberer, W., & Beutel, H.
- Venue
- IEEE Transactions on Advanced Packaging
- Published
- 2001-08
- Volume
- 24
- Issue
- 3
- Pages
- 366-374
- ISSN
- 1521-3323 (ISSN-L)
- 1557-9980
- OpenAlex
- W2122276783
- Cited by
- 145
- References
- 3
- FWCI
- 4.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High density interconnects and flexible hybrid assemblies for active biomedical implants. https://app.cochat.ai/papers/10.1109/6040.938305
- The paper
- Meyer, J.-U., Stieglitz, T., Scholz, O., Haberer, W., & Beutel, H. (2001). High density interconnects and flexible hybrid assemblies for active biomedical implants. IEEE Transactions on Advanced Packaging. https://doi.org/10.1109/6040.938305
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.