A flexible, light-weight multichannel sieve electrode with integrated cables for interfacing regenerating peripheral nerves
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Polyimide-based sieve electrodes are biocompatible and stable over several months for in vivo implantation and testing.
“Polyimide-based sieve electrodes have been shown to be biocompatible (Stieglitz et al., 1997) and stable over several months for in vivo implantation and testing (Navarro et al., 1998).”
From Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review. (2017) · cites this paper as Stieglitz et al., 1997
Cites
Edell, D. J. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325892 · Cited by 177 · see citing works
Kovacs, G. T. A., Storment, C. W., Halks-Miller, M., Belczynski, C. R., Santina, C. C. D., Lewis, E. R., & Maluf, N. I. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.293244 · Cited by 161 · see citing works
A micromachined silicon sieve electrode for nerve regeneration applications
Akin, T., Najafi, K., Smoke, R. H., & Bradley, R. M. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.284958 · Cited by 144 · see citing works
Functional regeneration of glossopharyngeal nerve through micromachined sieve electrode arrays
Bradley, R. M., Smoke, R. H., Akın, T., & Najafi, K. (1992) · Brain Research · doi:10.1016/0006-8993(92)91031-9 · Cited by 44 · see citing works
Perforated silicon dices with integrated nerve guidance channels for interfacing peripheral nerves
Meyer, J.-U., Beutel, H., Valderrama, E., Cabruja, E., Aebischer, P., Soldani, G., & Dario, P. (1995) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.1995.472594 · Cited by 13 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845 · see citing works
Self-citationWireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656 · see citing works
Flexible polyimide-based intracortical electrode arrays with bioactive capability
Rousche, P. J., Pellinen, D. S., Pivin, D. P., Williams, J. C., Vetter, R. J., & Kipke, D. R. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914800 · Cited by 644 · see citing works
Piech, D. K., Johnson, B. C., Shen, K., Ghanbari, M. M., Li, K. Y., Neely, R. M., Kay, J. E., Carmena, J. M., Maharbiz, M. M., & Muller, R. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0518-9 · Cited by 442 · see citing works
A Materials Roadmap to Functional Neural Interface Design
Wellman, S. M., Eles, J. R., Ludwig, K. A., Seymour, J. P., Michelson, N. J., McFadden, W. E., Vazquez, A. L., & Kozai, T. D. Y. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701269 · Cited by 389 · see citing works
Subbaroyan, J., Martin, D. C., & Kipke, D. R. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/4/006 · Cited by 368 · see citing works
Lago, N., Yoshida, K., Koch, K. P., & Navarro, X. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.886617 · Cited by 227 · see citing works
3D flexible multichannel neural probe array
Takeuchi, S., Suzuki, T. J., Mabuchi, K., & Fujita, H. (2003) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/14/1/014 · Cited by 221 · see citing works
Safety of long-term electrical peripheral nerve stimulation: review of the state of the art
Günter, C., Delbeke, J., & Ortiz-Catalan, M. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0474-8 · Cited by 198 · see citing works
Polyimide cuff electrodes for peripheral nerve stimulation
Rodri´guez, F. J., Ceballos, D., Schu¨ttler, M., Valero, A., Valderrama, E., Stieglitz, T., & Navarro, X. (2000) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(00)00192-8 · Cited by 207 · see citing works
Self-citationImplantable microscale neural interfaces
Cheung, K. C. (2007) · Biomedical Microdevices · doi:10.1007/s10544-006-9045-z · Cited by 202 · see citing works
Flexible, Penetrating Brain Probes Enabled by Advances in Polymer Microfabrication
Weltman, A., Yoo, J. J., & Meng, E. F. (2016) · Micromachines · doi:10.3390/mi7100180 · Cited by 180 · see citing works
Wireless Power Delivery to Flexible Subcutaneous Implants Using Capacitive Coupling
Jegadeesan, R., Agarwal, K., Guo, Y.-X., Yen, S., & Thakor, N. (2017) · IEEE transactions on microwave theory and techniques · doi:10.1109/tmtt.2016.2615623 · Cited by 157 · see citing works
Lago, N., Ceballos, D., J Rodrı́guez, F., Stieglitz, T., & Navarro, X. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.06.025 · Cited by 178 · see citing works
Self-citationMaterials for microfabricated implantable devices: a review
Scholten, K., & Meng, E. F. (2015) · Lab on a Chip · doi:10.1039/c5lc00809c · Cited by 161 · see citing works
Review of polymer MEMS micromachining
Kim, B., & Meng, E. F. (2015) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/26/1/013001 · Cited by 152 · see citing works
High density interconnects and flexible hybrid assemblies for active biomedical implants
Meyer, J.-U., Stieglitz, T., Scholz, O., Haberer, W., & Beutel, H. (2001) · IEEE Transactions on Advanced Packaging · doi:10.1109/6040.938305 · Cited by 145 · see citing works
Self-citationA review for the peripheral nerve interface designer
Larson, C. E., & Meng, E. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108523 · Cited by 133 · see citing works
Flexible Electrodes for Brain–Computer Interface System
Wang, J., Wang, T., Liu, H., Wang, K., Kumi, M., Feng, Z., Li, P., & Huang, W. (2023) · Advanced Materials · doi:10.1002/adma.202211012 · Cited by 138 · see citing works
Origami-enabled deformable silicon solar cells
Tang, R., Huang, H. M., Tu, H., Liang, H., Liang, M., Song, Z., Xu, Y. P., Jiang, H., & Yu, H. (2014) · Applied Physics Letters · doi:10.1063/1.4866145 · Cited by 134 · see citing works
Thin films and microelectrode arrays for neuroprosthetics
Ordonez, J., Schuettler, M., Boehler, C., Boretius, T., & Stieglitz, T. (2012) · MRS Bulletin · doi:10.1557/mrs.2012.117 · Cited by 118 · see citing works
Self-citationLawrence, S. M., Dhillon, G. S., Jensen, W., Yoshida, K., & Horch, K. W. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.831491 · Cited by 106 · see citing works
Riso, R. R. (1999) · Technology and Health Care · doi:10.3233/thc-1999-7604 · Cited by 98 · see citing works
Tissue-engineered peripheral nerve interfaces
Spearman, B. S., Desai, V. H., Mobini, S., McDermott, M. D., Graham, J. B., Otto, K. J., Judy, J. W., & Schmidt, C. E. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701713 · Cited by 96 · see citing works
Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review.
Ghafoor, U., Kim, S., & Hong, K.-S. (2017) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2017.00059 · Cited by 88 · see citing works
“Polyimide-based sieve electrodes have been shown to be biocompatible (Stieglitz et al., 1997) and stable over several months for in vivo implantation and testing (Navarro et al., 1998).”
Fabrication and characteristics of an implantable, polymer-based, intrafascicular electrode
Lawrence, S. M., Dhillon, G. S., & Horch, K. W. (2003) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(03)00231-0 · Cited by 93 · see citing works
Progress in the development of a multifunctional hand prosthesis
Pylatiuk, C., Mounier, S., Kargov, A., Schulz, S., & Bretthauer, G. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2004.1404187 · Cited by 88 · see citing works
The Evolution of Neuroprosthetic Interfaces
Adewole, D. O., Serruya, M. D., Harris, J. P., Burrell, J. C., Petrov, D., Chen, H.-C. I., Wolf, J. A., & Cullen, D. K. (2016) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.2016017198 · Cited by 81 · see citing works
Stieglitz, T., Ruf, H. H., Gross, M., Schüettler, M., & Meyer, J.-U. (2002) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(02)00019-2 · Cited by 77 · see citing works
Self-citationA Micro-Electrocorticography Platform and Deployment Strategies for Chronic BCI Applications
Thongpang, S., Richner, T. J., Brodnick, S. K., Schendel, A. A., Kim, J., Wilson, J. A., Hippensteel, J. A., Krugner-Higby, L. A., Moran, D., Ahmed, A. S., et al. (2011) · Clinical EEG and Neuroscience · doi:10.1177/155005941104200412 · Cited by 76 · see citing works
Long Micro-Channel Electrode Arrays: A Novel Type of Regenerative Peripheral Nerve Interface
Lacour, S. P., Fitzgerald, J. J., Lago, N., Tarte, E., McMahon, S., & Fawcett, J. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2031241 · Cited by 75 · see citing works
Flexible biomedical microdevices with double-sided electrode arrangements for neural applications
Stieglitz, T. (2001) · Sensors and Actuators A Physical · doi:10.1016/s0924-4247(01)00520-9 · Cited by 75 · see citing works
Self-citationEncapsulation of organic field effect transistors for flexible biomedical microimplants
Feili, D., Schüettler, M., Doerge, T., Kammer, S., & Stieglitz, T. (2005) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2004.11.021 · Cited by 72 · see citing works
Self-citationChronic multichannel neural recordings from soft regenerative microchannel electrodes during gait
Musick, K. M., Rigosa, J., Narasimhan, S., Wurth, S., Capogrosso, M., Chew, D. J., Fawcett, J. W., Micera, S., & Lacour, S. P. (2015) · Scientific Reports · doi:10.1038/srep14363 · Cited by 70 · see citing works
Lago, N., Udina, E., Ramachandran, A., & Navarro, X. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.891168 · Cited by 68 · see citing works
Polymer Hydrogel Microelectrodes for Neural Communication
Nyberg, T., Inganäs, O., & Jerregård, H. (2002) · Biomedical Microdevices · doi:10.1023/a:1014219828983 · Cited by 68 · see citing works
Manufacturing, assembling and packaging of miniaturized neural implants
Stieglitz, T. (2010) · Microsystem Technologies · doi:10.1007/s00542-009-0988-x · Cited by 67 · see citing works
Self-citation"Microflex" - A New Assembling Technique for Interconnects
Stieglitz, T., Beutel, H., & Meyer, J.-U. (2000) · Journal of Intelligent Material Systems and Structures · doi:10.1106/r7bv-511b-21rj-r2fa · Cited by 67 · see citing works
Self-citationKlinge, P. M., Vafa, M. A., Brinker, T., Brandis, A., Walter, G. F., Stieglitz, T., Samii, M., & Wewetzer, K. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00420-8 · Cited by 64 · see citing works
Self-citationOptogenetic micro-electrocorticography for modulating and localizing cerebral cortex activity
Richner, T. J., Thongpang, S., Brodnick, S. K., Schendel, A. A., Falk, R., Krugner-Higby, L. A., Pashaie, R., & Williams, J. C. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/1/016010 · Cited by 62 · see citing works
Ceballos, D., Valero‐Cabré, A., Valderrama, E., Schüttler, M., Stieglitz, T., & Navarro, X. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10099 · Cited by 61 · see citing works
Self-citationNeural interfaces for regenerated nerve stimulation and recording
Dario, P., Garzella, P., Toro, M., Micera, S., Alavi, M., Meyer, U., Valderrama, E., Sebatiani, L., Ghelarducci, B., Mazzoni, C., et al. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.736149 · Cited by 58 · see citing works
Graudejus, O., Yu, Z., Jones, J., Morrison, B., & Wagner, S. (2009) · Journal of The Electrochemical Society · doi:10.1149/1.3115465 · Cited by 57 · see citing works
Polyimide micro-channel arrays for peripheral nerve regenerative implants
Lacour, S. P., Atta, R., FitzGerald, J. J., Blamire, M., Tarte, E., & Fawcett, J. (2008) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2008.05.031 · Cited by 56 · see citing works
Negredo, P., Castro, J. E., Lago, N., Navarro, X., & Avendaño, C. (2004) · Neuroscience · doi:10.1016/j.neuroscience.2004.07.017 · Cited by 55 · see citing works
Pelkonen, A., Pistono, C., Klecki, P., Gómez‐Budia, M., Dougalis, A., Konttinen, H., Stanová, I., Fagerlund, I., Leinonen, V., Korhonen, P., et al. (2021) · Cells · doi:10.3390/cells11010106 · Cited by 50 · see citing works
Zhou, H., Li, G., Sun, X.-N., Zhu, Z.-H., Jin, Q., Zhao, J., & Ren, Q. (2009) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2008.2011122 · Cited by 50 · see citing works
Regenerated sciatic nerve axons stimulated through a chronically implanted macro-sieve electrode
MacEwan, M. R., Zellmer, E. R., Wheeler, J. J., Burton, H., & Moran, D. W. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00557 · Cited by 48 · see citing works
Ramachandran, A., Schuettler, M., Lago, N., Doerge, T., Koch, K. P., Navarro, X., Hoffmann, K.-P., & Stieglitz, T. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/2/005 · Cited by 46 · see citing works
Self-citationRegenerative Scaffold Electrodes for Peripheral Nerve Interfacing
Clements, I. P., Mukhatyar, V. J., Srinivasan, A., Bentley, J. T., Andreasen, D. S., & Bellamkonda, R. V. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2217352 · Cited by 46 · see citing works
Cobo, A., Larson, C. E., Scholten, K., Miranda, J. A., Elyahoodayan, S., Song, D. B., Pikov, V., & Meng, E. F. (2018) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2018.2881908 · Cited by 43 · see citing works
Jiang, X., Sui, X., Lu, Y., Yan, Y., Zhou, C., Li, L., Ren, Q., & Chai, X. (2013) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-10-48 · Cited by 43 · see citing works
Feili, D., Schüettler, M., Doerge, T., Kammer, S., Hoffmann, K. P., & Stieglitz, T. (2006) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/16/8/016 · Cited by 42 · see citing works
Self-citationMyllymaa, S., Myllymaa, K., Korhonen, H., Töyräs, J., Jääskeläinen, J. E., Djupsund, K., Tanila, H., & Lappalainen, R. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.03.028 · Cited by 41 · see citing works
Spinal Cord Injury: Present and Future Therapeutic Devices and Prostheses
Giszter, S. F. (2008) · Neurotherapeutics · doi:10.1016/j.nurt.2007.10.062 · Cited by 37 · see citing works
Multimodal Characterization of Neural Networks Using Highly Transparent Electrode Arrays
Donahue, M. J., Kaszás, A., Turi, G. F., Rózsa, B. J., Slézia, A., Vanzetta, I., Katona, G., Bernard, C., Malliaras, G. G., & Williamson, A. (2018) · eNeuro · doi:10.1523/eneuro.0187-18.2018 · Cited by 34 · see citing works
Flexible UV‐Ozone‐Modified Carbon Nanotube Electrodes for Neuronal Recording
Hsu, H., Teng, I., Chen, Y., Hsu, W., Lee, Y., Yen, S., Su, H., Yeh, S., Chen, H., & Yew, T. (2010) · Advanced Materials · doi:10.1002/adma.200903413 · Cited by 36 · see citing works
Next-generation flexible neural and cardiac electrode arrays
Kim, J., Lee, M., Rhim, J. S., Wang, P., Lu, N., & Kim, D. (2014) · Biomedical Engineering Letters · doi:10.1007/s13534-014-0132-4 · Cited by 35 · see citing works
The development of a multichannel electrode array for retinal prostheses
Terasawa, Y., Tashiro, H., Uehara, A., Saitoh, T., Ozawa, M., Tokuda, T., & Ohta, J. (2006) · Journal of Artificial Organs · doi:10.1007/s10047-006-0352-1 · Cited by 31 · see citing works
Feasibility of Microelectrode Array (MEA) Based on Silicone-Polyimide Hybrid for Retina Prosthesis
Kim, E., Kim, C., Lee, S. W., Seo, J.-M., Chung, H., & Kim, S. J. (2009) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.08-2500 · Cited by 30 · see citing works
Kuliasha, C. A., & Judy, J. W. (2021) · Advanced Materials Technologies · doi:10.1002/admt.202100149 · Cited by 27 · see citing works
Development of flexible stimulation devices for a retina implant system
Stieglitz, T., Beutel, H., Keller, R., Blau, C., & Meyer, J.-U. (1997) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1997.758825 · Cited by 26 · see citing works
Self-citationRapid prototyping of flexible intrafascicular electrode arrays by picosecond laser structuring
Mueller, M. C., de la Oliva, N., del Valle, J., Delgado-Martínez, I., Navarro, X., & Stieglitz, T. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa7eea · Cited by 24 · see citing works
Self-citationA robust polymer microcable structure for flexible devices
Kim, E. H., Tu, H., Lv, C. X., Jiang, H., Yu, H., & Xu, Y. P. (2013) · Applied Physics Letters · doi:10.1063/1.4788917 · Cited by 23 · see citing works
Micromachining of flexible neural implants with low-ohmic wire traces using electroplating
Gross, M., Altpeter, D., Stieglitz, T., Schüettler, M., & Meyer, J.-U. (2002) · Sensors and Actuators A Physical · doi:10.1016/s0924-4247(01)00768-3 · Cited by 20 · see citing works
Self-citationN3-MEA Probes: Scooping Neuronal Networks
Kireev, D., Montes, V. R., Stevanovic, J., Srikantharajah, K., & Offenhäusser, A. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00320 · Cited by 18 · see citing works
Kim, H., Dingle, A. M., Ness, J. P., Baek, D.-H., Bong, J., Lee, I. K., Shulzhenko, N. O., Zeng, W., Israel, J. S., Pisaniello, J. A., et al. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2020.108602 · Cited by 19 · see citing works
A dry release of polyimide electrodes using Kapton film and application to EEG signal measurements
Baek, D.-H., Moon, J., Choi, Y. Y., Lee, M., Choi, J. H., Pak, J. J., & Lee, S. (2010) · Microsystem Technologies · doi:10.1007/s00542-010-1152-3 · Cited by 19 · see citing works
Stieglitz, T., Schüettler, M., Rubehn, B., Boretius, T., Badía, J., & Navarro, X. (2011) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2011.5910602 · Cited by 19 · see citing works
Self-citationTu, H., & Xu, Y. P. (2012) · Applied Physics Letters · doi:10.1063/1.4739937 · Cited by 18 · see citing works
Additive Processes for Polymeric Materials
Meng, E. F., Zhang, X., & Benard, W. L. (2011) · MEMS reference shelf/MEMS reference Shelf · doi:10.1007/978-0-387-47318-5_4 · Cited by 17 · see citing works
Stieglitz, T., Schüettler, M., & Koch, K. P. (2004) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt.2004.015 · Cited by 17 · see citing works
Self-citationBiomedical microdevices for neural interfaces
Meyer, J.-U., Schüettler, M., Thielecke, H., & Stieglitz, T. (2000) · International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine and Biology (MMB) · doi:10.1109/mmb.2000.893824 · Cited by 16 · see citing works
Self-citationDetection of cluster in Self-Organizing Maps for controlling a prostheses using nerve signals.
Bogdan, M., & Rosenstiel, W. (2001) · Publikation Server (Leipzig University) · Cited by 16 · see citing works
Suaning, G. J., Lovell, N. H., & Kwok, C. Y. (2003) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2003.07.002 · Cited by 16 · see citing works
Flexible and Soft Materials and Devices for Neural Interface
Castagnola, E., Zheng, X. S., & Cui, X. T. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_5 · Cited by 14 · see citing works
Feili, D., Schüettler, M., & Stieglitz, T. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/5/1/007 · Cited by 13 · see citing works
Self-citationA parylene cuff electrode for peripheral nerve recording and drug delivery
Cobo, A., Boyajian, B., Larson, C. E., Kee, S., Pikov, V., & Meng, E. F. (2017) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2017.7863454 · Cited by 12 · see citing works
A Microclip Peripheral Nerve Interface (μcPNI) for Bioelectronic Interfacing with Small Nerves
Rowan, C. C., Graudejus, O., & Otchy, T. M. (2021) · Advanced Science · doi:10.1002/advs.202102945 · Cited by 11 · see citing works
A microchannel neural interface with embedded microwires targeting the peripheral nervous system
Kim, B., Reyes, A., Garza, B., & Choi, Y. (2014) · Microsystem Technologies · doi:10.1007/s00542-014-2340-3 · Cited by 12 · see citing works
Metz, S. W., Oppliger, F., Holzer, R., Buisson, B., Bertrand, D., & Renaud, P. (2002) · International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine and Biology (MMB) · doi:10.1109/mmb.2000.893860 · Cited by 12 · see citing works
Schlosshauer, B., Brinker, T., Müller, H.-W., & Meyer, J.-U. (2001) · Brain Research · doi:10.1016/s0006-8993(01)02391-5 · Cited by 12 · see citing works
Self-citationPorous silicon as a neural electrode material
Persson, J., Danielsen, N., & Wallman, L. (2007) · Journal of Biomaterials Science Polymer Edition · doi:10.1163/156856207782177846 · Cited by 10 · see citing works
Klinge, P. M., Groos, S., Wewetzer, K., Haastert, K., Rosahl, S., Vafa, M. A., Hosseini, H., Samii, M., & Brinker, T. (2001) · Neuroreport · doi:10.1097/00001756-200105080-00043 · Cited by 10 · see citing works
Kim, Y. H., Lee, C., Ahn, K., Lee, M., & Kim, Y.-J. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.09.034 · Cited by 9 · see citing works
3D flexible multichannel probe array
Takeuchi, S., Suzuki, T., Mabuchi, K., & Fujita, H. (2003) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2003.1189762 · Cited by 9 · see citing works
Long term in vitro monitoring of polyimide microprobe electrical properties
Nikles, S. A., Pellinen, D. S., Kitagawa, J., Bradley, R. M., Kipke, D. R., & Najafi, K. (2004) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2003.1280860 · Cited by 9 · see citing works
Microflex: a new technique for hybrid integration for microsystems
Beutel, H., Stieglitz, T., & Meyer, J.-U. (2002) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.1998.659773 · Cited by 9 · see citing works
Self-citationGuo, L., Clements, I. P., Li, D., Bellamkonda, R. V., & DeWeerth, S. P. (2010) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2010.5709604 · Cited by 8 · see citing works
Real-time in vivo thoracic spinal glutamate sensing during myocardial ischemia
Salavatian, S., Robbins, E. M., Kuwabara, Y., Castagnola, E., Cui, X. T., & Mahajan, A. (2023) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00299.2023 · Cited by 7 · see citing works
Regenerative electrodes for interfacing injured peripheral nerves: neurobiological assessment
Lago, N., Udina, E., & Navarro, X. (2006) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2006.1639247 · Cited by 7 · see citing works
Versatile microflex-based interconnection technique
Beutel, H., Stieglitz, T., & Meyer, J.-U. (1998) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.320167 · Cited by 7 · see citing works
Self-citationMechanical Machining-based Three-Dimensional Electrode Array for Chronic Neural Stimulation
Terasawa, Y., Tashiro, H., Nakano, Y., Tokuda, T., & Ohta, J. (2016) · Advanced Biomedical Engineering · doi:10.14326/abe.5.137 · Cited by 6 · see citing works
Neuroprosthesis and Functional Electrical Stimulation (Peripheral)
Popović, D. B., & Popović‐Maneski, L. (2022) · Handbook of Neuroengineering · doi:10.1007/978-981-15-2848-4_51-1 · Cited by 5 · see citing works
A polymer-based spiky microelectrode array for electrocorticography
Márton, G., Kiss, M., Orbán, G., Pongracz, A., & Ulbert, I. (2014) · Microsystem Technologies · doi:10.1007/s00542-014-2203-y · Cited by 5 · see citing works
Artificial neural net based signal processing for interaction with peripheral nervous system
Bogdan, M., Schroder, M., & Rosenstiel, W. (2003) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/cne.2003.1196775 · Cited by 5 · see citing works
Sensing Nerve Activity with Scalable and Robust Nerve Interfaces
Kuliasha, C. A., Spearman, B. S., Atkinson, E. W., Rustogi, P., Fumiturewalla, A. S., Nunamaker, E. A., Otto, K. J., Schmidt, C. E., & Judy, J. W. (2019) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/sensors43011.2019.8956532 · Cited by 4 · see citing works
Development of flexible microelectrode arrays for recording cortical surface field potentials
Myllymaa, S., Myllymaa, K., Korhonen, H., Gureviciene, I., Djupsund, K., Tanila, H., & Lappalainen, R. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4649884 · Cited by 4 · see citing works
Thin-Film Microelectrode Arrays for Biomedical Applications
Cheung, K. C. (2010) · Biological and medical physics series · doi:10.1007/978-0-387-98120-8_6 · Cited by 3 · see citing works
Surface Activated Bonding Method for Flexible Lamination
Howlader, M. M. R., & Suga, T. (2007) · International Conference on Polymers and Adhesives in Microelectronics and Photonics · doi:10.1109/polytr.2007.4339181 · Cited by 3 · see citing works
- Authors
- Stieglitz, T., Beutel, H., & Meyer, J.-U.
- Affiliations
- Fraunhofer Institute for Biomedical Engineering (DE)
- Corresponding author
- Stieglitz, T
- ORCID
- Stieglitz, T
- Venue
- Sensors and Actuators A: Physical
- Publisher
- Elsevier BV
- Published
- 1997-05
- Volume
- 60
- Issue
- 1-3
- Pages
- 240-243
- ISSN
- 0924-4247 (ISSN-L)
- OpenAlex
- W2033812657
- Cited by
- 125
- References
- 5
- Citations by year
- 2026: 1 · 2023: 4 · 2022: 1 · 2021: 4 · 2020: 2 · 2019: 4 · 2018: 3 · 2017: 6 · 2016: 6 · 2015: 3 · 2014: 7 · 2013: 2 · 2012: 4
- FWCI
- 1.39
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Sensors and Actuators A Physical (publishedVersion)
- Publikationsdatenbank der Fraunhofer-Gesellschaft (Fraunhofer-Gesellschaft) (submittedVersion)
- Fraunhofer-Publica (Fraunhofer-Gesellschaft) (submittedVersion)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced MEMS and NEMS Technologies
- Keywords
- peripheral nerve regeneration, flexible electrodes, micromachining, insulation resistance, mechanical stability
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review