Cited by 125Neuroscience and Neural EngineeringAnalog and Mixed-Signal Circuit DesignAdvanced MEMS and NEMS Technologies

A flexible, light-weight multichannel sieve electrode with integrated cables for interfacing regenerating peripheral nerves

Stieglitz, T, Beutel, H, Meyer, J.-U·1997·Sensors and Actuators A: Physical

Integrity signals

Registry

Crossref · 10.1016/s0924-4247(97)01494-5

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Polyimide-based sieve electrodes are biocompatible and stable over several months for in vivo implantation and testing.

    “Polyimide-based sieve electrodes have been shown to be biocompatible (Stieglitz et al., 1997) and stable over several months for in vivo implantation and testing (Navarro et al., 1998).”

    From Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review. (2017) · cites this paper as Stieglitz et al., 1997

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Stieglitz, T., Beutel, H., & Meyer, J.-U.
Affiliations
Fraunhofer Institute for Biomedical Engineering (DE)
Corresponding author
Stieglitz, T
Venue
Sensors and Actuators A: Physical
Publisher
Elsevier BV
Published
1997-05
Volume
60
Issue
1-3
Pages
240-243
ISSN
0924-4247 (ISSN-L)
OpenAlex
W2033812657
Cited by
125
References
5
Citations by year
2026: 1 · 2023: 4 · 2022: 1 · 2021: 4 · 2020: 2 · 2019: 4 · 2018: 3 · 2017: 6 · 2016: 6 · 2015: 3 · 2014: 7 · 2013: 2 · 2012: 4
FWCI
1.39
Type
journal article
Language
en
Open access
closed
Locations
  • Sensors and Actuators A Physical (publishedVersion)
  • Publikationsdatenbank der Fraunhofer-Gesellschaft (Fraunhofer-Gesellschaft) (submittedVersion)
  • Fraunhofer-Publica (Fraunhofer-Gesellschaft) (submittedVersion)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced MEMS and NEMS Technologies
Keywords
peripheral nerve regeneration, flexible electrodes, micromachining, insulation resistance, mechanical stability

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review