The DOI matches its Crossref record.
A method of defining the load impedance specification for a stable distributed power system
Abstract
By applying the loop gain analysis technique, a forbidden region for the polar plot of the ratio of impedances at the interface between two cascaded power subsystems is determined. A method of transforming the forbidden region into a load impedance specification for a given source impedance is developed. The method assures system stability and minimal performance degradation of the distributed power system, while allowing impedance overlap at the interface.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
DC Microgrids–Part I: A Review of Control Strategies and Stabilization Techniques
Dragicevic, T., Lu, X., Vasquez, J., & Guerrero, J. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2478859 · Cited by 1,564
DC Microgrids—Part II: A Review of Power Architectures, Applications, and Standardization Issues
Dragicevic, T., Lu, X., Vasquez, J. C., & Guerrero, J. M. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2464277 · Cited by 1,451
Low-Voltage Bipolar-Type DC Microgrid for Super High Quality Distribution
Kakigano, H., Miura, Y., & Ise, T. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2077682 · Cited by 995
Impedance-Based Analysis of Grid-Synchronization Stability for Three-Phase Paralleled Converters
Wen, B., Dong, D., Boroyevich, D., Burgos, R., Mattavelli, P., & Shen, Z. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2419712 · Cited by 586
Impedance specifications for stable DC distributed power systems
Feng, X., Liu, J., & Lee, F. C. (2002) · IEEE Transactions on Power Electronics · doi:10.1109/63.988825 · Cited by 582
Self-citationReview on Control of DC Microgrids
Meng, L., Shafiee, Q., Ferrari Trecate, G., Karimi, H., Fulwani, D., Lu, X., & Guerrero, J. M. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2690219 · Cited by 513
Comprehensive Review of Stability Criteria for DC Power Distribution Systems
Riccobono, A., & Santi, E. (2014) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2014.2309800 · Cited by 459
Wen, B., Boroyevich, D., Burgos, R., Mattavelli, P., & Shen, Z. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2378731 · Cited by 453
Modeling and Stability Analysis of Islanded DC Microgrids Under Droop Control
Tahim, A. P. N., Pagano, D. J., Lenz, E., & Stramosk, V. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2360171 · Cited by 326
Sun, X., Lee, Y.-S., & Xu, D. (2003) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.810867 · Cited by 259
Huang, J., Corzine, K. A., & Belkhayat, M. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2007212 · Cited by 253
Analysis and Stabilization of a Smart Transformer-Fed Grid
Zou, Z.-X., Buticchi, G., & Liserre, M. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2733450 · Cited by 41
Metadata
- Authors
- Wildrick, C. M., Lee, F. C., Cho, B. H., & Choi, B.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 1995-05
- Volume
- 10
- Issue
- 3
- Pages
- 280-285
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2098332889
- Cited by
- 520
- References
- 0
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.