The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
A unified approach to statistical tomography using coordinate descent optimization
Abstract
Over the past years there has been considerable interest in statistically optimal reconstruction of cross-sectional images from tomographic data. In particular, a variety of such algorithms have been proposed for maximum a posteriori (MAP) reconstruction from emission tomographic data. While MAP estimation requires the solution of an optimization problem, most existing reconstruction algorithms take an indirect approach based on the expectation maximization (EM) algorithm. We propose a new approach to statistically optimal image reconstruction based on direct optimization of the MAP criterion. The key to this direct optimization approach is greedy pixel-wise computations known as iterative coordinate decent (ICD). We propose a novel method for computing the ICD updates, which we call ICD/Newton-Raphson. We show that ICD/Newton-Raphson requires approximately the same amount of computation per iteration as EM-based approaches, but the new method converges much more rapidly (in our experiments, typically five to ten iterations). Other advantages of the ICD/Newton-Raphson method are that it is easily applied to MAP estimation of transmission tomograms, and typical convex constraints, such as positivity, are easily incorporated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum Likelihood from Incomplete Data Via the EM Algorithm
Dempster, A. P., Laird, N. M., & Rubin, D. B. (1977) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1977.tb01600.x · Cited by 50,444
Maximum Likelihood from Incomplete Data via the EM Algorithm
Dempster, A. P., Laird, N. M., & Rubin, D. B. (1976) · Cited by 4,517
Maximum Likelihood Reconstruction for Emission Tomography
Shepp, L. A., & Vardi, Y. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307558 · Cited by 4,429
On the Statistical Analysis of Dirty Pictures
Besag, J. (1986) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1986.tb01412.x · Cited by 4,191
EM reconstruction algorithms for emission and transmission tomography.
Lange, K. L., & Carson, R. E. (1984) · PubMed · Cited by 1,769
Iterative Solution of Large Linear Systems
(1971) · Elsevier eBooks · doi:10.1016/c2013-0-11733-3 · Cited by 1,734
Numerical Recipes in C-The Art of Scientific Computing.
G., W., Press, W. H., Flannery, B. P., Teukolsky, S. A., & Vetterling, W. T. (1989) · Mathematics of Computation · doi:10.2307/2008673 · Cited by 1,513
Bayesian reconstructions from emission tomography data using a modified EM algorithm
Green, P. J. (1990) · IEEE Transactions on Medical Imaging · doi:10.1109/42.52985 · Cited by 1,241
A generalized Gaussian image model for edge-preserving MAP estimation
Bouman, C., & Sauer, K. (1993) · IEEE Transactions on Image Processing · doi:10.1109/83.236536 · Cited by 884
Self-citationA Statistical Model for Positron Emission Tomography
Vardi, Y., Shepp, L. A., & Kaufman, L. (1985) · Journal of the American Statistical Association · doi:10.1080/01621459.1985.10477119 · Cited by 863
A generalized EM algorithm for 3-D Bayesian reconstruction from Poisson data using Gibbs priors
Hebert, T., & Leahy, R. (1989) · IEEE Transactions on Medical Imaging · doi:10.1109/42.24868 · Cited by 622
Penalized weighted least-squares image reconstruction for positron emission tomography
Fessler, J. A. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.293921 · Cited by 611
A local update strategy for iterative reconstruction from projections
Sauer, K., & Bouman, C. (1993) · IEEE Transactions on Signal Processing · doi:10.1109/78.193196 · Cited by 494
Self-citationDe Pierro, A. R. (1995) · IEEE Transactions on Medical Imaging · doi:10.1109/42.370409 · Cited by 475
Convergence of EM image reconstruction algorithms with Gibbs smoothing
Lange, K. (1990) · IEEE Transactions on Medical Imaging · doi:10.1109/42.61759 · Cited by 400
A Theoretical Study of Some Maximum Likelihood Algorithms for Emission and Transmission Tomography
Lange, K., Bahn, M., & Little, R. (1987) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1987.4307810 · Cited by 330
Globally convergent algorithms for maximum a posteriori transmission tomography
Lange, K., & Fessler, J. A. (1995) · IEEE Transactions on Image Processing · doi:10.1109/83.465107 · Cited by 313
Implementing and Accelerating the EM Algorithm for Positron Emission Tomography
Kaufman, L. (1987) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1987.4307796 · Cited by 293
Physical performance of the latest generation of commercial positron scanner
Spinks, T. J., Jones, T., Gilardi, M. C., & Heather, J. D. (1988) · IEEE Transactions on Nuclear Science · doi:10.1109/23.12819 · Cited by 287
Fast gradient-based methods for Bayesian reconstruction of transmission and emission PET images
Mumcuoglu, E. U., Leahy, R., Cherry, S. R., & Zhou, Z. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.363099 · Cited by 282
The Use of Sieves to Stabilize Images Produced with the EM Algorithm for Emission Tomography
Snyder, D. L., & Miller, M. I. (1985) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1985.4334521 · Cited by 278
Stopping Rule for the MLE Algorithm Based on Statistical Hypothesis Testing
Veklerov, E., & Llacer, J. (1987) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1987.4307849 · Cited by 254
ML parameter estimation for Markov random fields with applications to Bayesian tomography
Saquib, S. S., Bouman, C. A., & Sauer, K. (1998) · IEEE Transactions on Image Processing · doi:10.1109/83.701163 · Cited by 159
Self-citationPolitte, D. G., & Snyder, D. L. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.75614 · Cited by 147
Herman, G. T., & Odhner, D. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.97583 · Cited by 104
Discontinuity preserving regularization of inverse visual problems
Stevenson, R. L., Schmitz, B. E., & Delp, E. J. (1994) · IEEE Transactions on Systems Man and Cybernetics · doi:10.1109/21.278994 · Cited by 90
Ollinger, J. M. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.276147 · Cited by 88
Fast MLE for SPECT using an intermediate polar representation and a stopping criterion
Hebert, T. J., Leahy, R. M., & Singh, M. (1988) · IEEE Transactions on Nuclear Science · doi:10.1109/23.12798 · Cited by 71
On methods for maximum a posteriori image reconstruction with a normal prior
Herman, G. T., Pierro, Á. R. D., & Gai, N. (1992) · Journal of Visual Communication and Image Representation · doi:10.1016/1047-3203(92)90035-r · Cited by 40
Bayesian Image Processing in Two Dimensions
Hart, H. E., & Liang, Z. (1987) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1987.4307828 · Cited by 38
Hart, H. E., & Liang, Z. (1987) · Bulletin of Mathematical Biology · doi:10.1007/bf02459960 · Cited by 32
Joint maximum likelihood estimation of emission and attenuation densities in PET
Clinthorne, N. H., Fessler, J. A., Hutchins, G. D., & Rogers, W. L. (2002) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.1991.259253 · Cited by 22
Liang, Z., & HART, H. (1987) · Bulletin of Mathematical Biology · doi:10.1007/bf02459959 · Cited by 21
Cited by
Wright, S. J. (2015) · Mathematical Programming · doi:10.1007/s10107-015-0892-3 · Cited by 1,438
Plug-and-Play priors for model based reconstruction
Venkatakrishnan, S. V., Bouman, C. A., & Wohlberg, B. (2013) · 2013 IEEE Global Conference on Signal and Information Processing · doi:10.1109/globalsip.2013.6737048 · Cited by 1,178
Self-citationOllinger, J. M., & Fessler, J. A. (1997) · IEEE Signal Processing Magazine · doi:10.1109/79.560323 · Cited by 1,167
Space-alternating generalized expectation-maximization algorithm
Fessler, J. A., & Hero, A. O. (1994) · IEEE Transactions on Signal Processing · doi:10.1109/78.324732 · Cited by 1,063
A three‐dimensional statistical approach to improved image quality for multislice helical CT
Thibault, J., Sauer, K. D., Bouman, C. A., & Hsieh, J. (2007) · Medical Physics · doi:10.1118/1.2789499 · Cited by 937
Self-citation
Metadata
- Authors
- Bouman, C. A., & Sauer, K.
- Venue
- IEEE Transactions on Image Processing
- Published
- 1996-03
- Volume
- 5
- Issue
- 3
- Pages
- 480-492
- ISSN
- 1057-7149 (ISSN-L)
- 1941-0042
- OpenAlex
- W2110733023
- Cited by
- 442
- References
- 33
- FWCI
- 11.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.