Implantable transducer for two-degree of freedom joint angle sensing
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
An implantable joint angle transducer (IJAT) was developed to provide command-control and feedback-control information for chronic use with functional neuromuscular stimulation (FNS) neuroprostheses. The IJAT uses Hall effect sensors to transduce joint angle. A titanium encapsulated array of Hall effect sensors and support circuitry is surgically implanted in one bone, and a similarly encapsulated permanent magnet in an opposing bone, across a joint. The IJAT provides consistent, reliable, high quality signals that reflect joint movement from midsized two-degree-of-freedom joints. IJAT's were implanted using a chronic in vivo dog model to demonstrate the feasibility of implantation and periodic measurement techniques, and to validate modeling techniques used for prediction of function and calibration. The flexion resolution ranged from 0.4 to 3.0 degrees over a range of 115 degrees. The maximum deviation from a linear response was 9 degrees. The resolution and linearity depend on several transducer and joint geometry parameters, and can be predicted prior to implantation and calibrated after implantation. The results of this study 1) defined the most appropriate hermetic capsule designs for the IJAT sensor and magnet, 2) defined the best orientation of the magnetic field to optimize device function, 3) provided a computer model of the IJAT to aid in placement, calibration, and evaluation of the device, 4) verified the surgical techniques used to implant the device, and 5) verified the long-term functionality and the biocompatibility of the device.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Smith, B., Tang, Z., Johnson, M. W., Pourmehdi, S., Gazdik, M. M., Buckett, J. R., & Peckham, P. H. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.664202 · Cited by 270
Self-citationAn Implanted Upper-Extremity Neuroprosthesis. Follow-up of Five Patients*
KILGORE, K. L., PECKHAM, P. H., KEITH, M. W., THROPE, G. B., WUOLLE, K. S., BRYDEN, A. M., & HART, R. L. (1997) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199704000-00008 · Cited by 192
Self-citation
Cited by
Functional Electrical Stimulation for Neuromuscular Applications
Peckham, P. H., & Knutson, J. S. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140103 · Cited by 784
Self-citationNeuromuscular electrical stimulation in neurorehabilitation
Sheffler, L. R., & Chae, J. (2007) · Muscle & Nerve · doi:10.1002/mus.20758 · Cited by 529
Smith, B., Tang, Z., Johnson, M. W., Pourmehdi, S., Gazdik, M. M., Buckett, J. R., & Peckham, P. H. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.664202 · Cited by 270
“An IJAT is used to acquire joint angle information from midsized joints (Fig. 9) [ 17 ].”
MethodSelf-citationImplanted stimulators for restoration of function in spinal cord injury
Bhadra, N., Kilgore, K. L., & Peckham, P. H. (2001) · Medical Engineering & Physics · doi:10.1016/s1350-4533(01)00012-1 · Cited by 92
Self-citationRaspopovic, S., Carpaneto, J., Udina, E., Navarro, X., & Micera, S. (2010) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-7-17 · Cited by 81
Metadata
- Authors
- Johnson, M. W., Peckham, P. H., Bhadra, N., Kilgore, K. L., Gazdik, M. M., Keith, M. W., & Strojnik, P.
- Venue
- IEEE Transactions on Rehabilitation Engineering
- Published
- 1999
- Volume
- 7
- Issue
- 3
- Pages
- 349-359
- ISSN
- 1063-6528 (ISSN-L)
- OpenAlex
- W2119391661
- Cited by
- 65
- References
- 2
- FWCI
- 1.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Implantable transducer for two-degree of freedom joint angle sensing. https://app.cochat.ai/papers/10.1109/86.788471
- The paper
- Johnson, M. W., Peckham, P. H., Bhadra, N., Kilgore, K. L., Gazdik, M. M., Keith, M. W., & Strojnik, P. (1999). Implantable transducer for two-degree of freedom joint angle sensing. IEEE Transactions on Rehabilitation Engineering. https://doi.org/10.1109/86.788471
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.