The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Noise Reduction in ECG Signals Using Fully Convolutional Denoising Autoencoders
Open accessAbstract
The electrocardiogram (ECG) is an efficient and noninvasive indicator for arrhythmia detection and prevention. In real-world scenarios, ECG signals are prone to be contaminated with various noises, which may lead to wrong interpretation. Therefore, significant attention has been paid on denoising of ECG for accurate diagnosis and analysis. A denoising autoencoder (DAE) can be applied to reconstruct the clean data from its noisy version. In this paper, a DAE using the fully convolutional network (FCN) is proposed for ECG signal denoising. Meanwhile, the proposed FCN-based DAE can perform compression with regard to the DAE architecture. The proposed approach is applied to ECG signals from the MIT-BIH Arrhythmia database and the added noise signals are obtained from the MIT-BIH Noise Stress Test database. The denoising performance is evaluated using the root-mean-square error (RMSE), percentage-root-mean-square difference (PRD), and improvement in signal-to-noise ratio (SNRimp). The results of the experiments conducted on noisy ECG signals of different levels of input SNR show that the FCN acquires better performance as compared to the deep fully connected neural network- and convolutional neural network-based denoising models. Moreover, the proposed FCN-based DAE reduces the size of the input ECG signals, where the compressed data is 32 times smaller than the original. The results of the study demonstrate the superiority of FCN in denoising, with lower RMSE and PRD, as well as higher SNRimp. According to the results, we believe that the proposed FCN-based DAE has a good application prospect in clinical practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adam: A Method for Stochastic Optimization
Kingma, D. P., & Ba, J. (2014) · arXiv · doi:10.48550/arxiv.1412.6980 · Cited by 98,946
Fully convolutional networks for semantic segmentation
Long, J., Shelhamer, E., & Darrell, T. (2015) · 2015 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2015.7298965 · Cited by 38,834
Batch Normalization: Accelerating Deep Network Training by Reducing Internal Covariate Shift
Ioffe, S., & Szegedy, C. (2015) · arXiv · doi:10.48550/arxiv.1502.03167 · Cited by 27,818
Huang, N. E., Shen, Z., Long, S. R., Wu, M. C., Shih, H. H., Zheng, Q., Yen, N.-C., Tung, C. C., & Liu, H. H. (1998) · Proceedings of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rspa.1998.0193 · Cited by 23,564
Heart Disease and Stroke Statistics—2017 Update: A Report From the American Heart Association
Benjamin, E. J., Blaha, M. J., Chiuve, S. E., Cushman, M., Das, S. R., Deo, R., de Ferranti, S. D., Floyd, J., Fornage, M., Gillespie, C., et al. (2017) · Circulation · doi:10.1161/cir.0000000000000485 · Cited by 12,591
Global status report on noncommunicable diseases 2010.
Alwan, A. (2011) · Cited by 8,494
Extracting and composing robust features with denoising autoencoders
Vincent, P., Larochelle, H., Bengio, Y., & Manzagol, P.-A. (2008) · Proceedings of the 25th international conference on Machine learning - ICML '08 · doi:10.1145/1390156.1390294 · Cited by 7,436
DeepFace: Closing the Gap to Human-Level Performance in Face Verification
Taigman, Y., Yang, M., Ranzato, M., & Wolf, L. (2014) · 2014 IEEE Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2014.220 · Cited by 6,542
Fast and Accurate Deep Network Learning by Exponential Linear Units (ELUs)
Clevert, D.-A., Unterthiner, T., & Hochreiter, S. (2015) · arXiv · doi:10.48550/arxiv.1511.07289 · Cited by 4,513 · cited 1×
“We employed exponential linear units (ELU) [29] as activation functions for hidden layers, and there is no activation function for the output layer in the FCN model.”
MethodConvergence Results for Neural Networks via Electrodynamics
Panigrahy, R., Rahimi, A., Sachdeva, S., & Zhang, Q. (2018) · Leibniz international proceedings in informatics · doi:10.4230/lipics.itcs.2018.22 · Cited by 2,761
Speech enhancement based on deep denoising autoencoder
Lu, X., Tsao, Y., Matsuda, S., & Hori, C. (2013) · Interspeech 2013 · doi:10.21437/interspeech.2013-130 · Cited by 834
Self-citationMedical Image Denoising Using Convolutional Denoising Autoencoders
Gondara, L. (2016) · 2016 IEEE 16th International Conference on Data Mining Workshops (ICDMW) · doi:10.1109/icdmw.2016.0041 · Cited by 737
Denoising of ECG signals based on noise reduction algorithms in EMD and wavelet domains
Kabir, M. A., & Shahnaz, C. (2012) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2011.11.003 · Cited by 444
PhysioNet: a Web-based resource for the study of physiologic signals
Moody, G. B., Mark, R. G., & Goldberger, A. L. (2001) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.932728 · Cited by 386
Binary coding of speech spectrograms using a deep auto-encoder
Deng, L., Seltzer, M. L., Yu, D., Acero, A., Mohamed, A.-R., & Hinton, G. (2010) · Interspeech 2010 · doi:10.21437/interspeech.2010-487 · Cited by 375
Image Restoration Using Convolutional Auto-encoders with Symmetric Skip Connections
Mao, X.-J., Shen, C., & Yang, Y.-B. (2016) · arXiv (Cornell University) · doi:10.48550/arxiv.1606.08921 · Cited by 323
Fu, S.-W., Wang, T.-W., Tsao, Y., Lu, X., & Kawai, H. (2018) · IEEE/ACM Transactions on Audio, Speech, and Language Processing · doi:10.1109/taslp.2018.2821903 · Cited by 314
Self-citationVentricular arrhythmias and sudden cardiac death
John, R. M., Tedrow, U. B., Koplan, B. A., Albert, C. M., Epstein, L. M., Sweeney, M. O., Miller, A. L., Michaud, G. F., & Stevenson, W. G. (2012) · The Lancet · doi:10.1016/s0140-6736(12)61413-5 · Cited by 286
Raw waveform-based speech enhancement by fully convolutional networks
Fu, S.-W., Tsao, Y., Lu, X., & Kawai, H. (2017) · 2017 Asia-Pacific Signal and Information Processing Association Annual Summit and Conference (APSIPA ASC) · doi:10.1109/apsipa.2017.8281993 · Cited by 221
Self-citationAn efficient compression of ECG signals using deep convolutional autoencoders
Yildirim, O., Tan, R. S., & Acharya, U. R. (2018) · Cognitive Systems Research · doi:10.1016/j.cogsys.2018.07.004 · Cited by 205
ECG signal enhancement based on improved denoising auto-encoder
Xiong, P., Wang, H., Liu, M., Zhou, S., Hou, Z., & Liu, X. (2016) · Engineering Applications of Artificial Intelligence · doi:10.1016/j.engappai.2016.02.015 · Cited by 170
Gogna, A., Majumdar, A., & Ward, R. K. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2631620 · Cited by 157
Patient-Specific Deep Architectural Model for ECG Classification
Luo, K., Li, J., Wang, Z., & Cuschieri, A. (2017) · Journal of Healthcare Engineering · doi:10.1155/2017/4108720 · Cited by 147
ECG Denoising Based on the Empirical Mode Decomposition
Weng, B., Blanco–Velasco, M., & Barner, K. E. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.259340 · Cited by 146
Lai, Y.-H., Chen, F., Wang, S., Lu, X., Tsao, Y., & Lee, C. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2613960 · Cited by 122
Self-citationDeep Ordinal Hashing With Spatial Attention
Jin, L., Shu, X., Li, K., Li, Z., Qi, G.-J., & Tang, J. (2018) · IEEE Transactions on Image Processing · doi:10.1109/tip.2018.2883522 · Cited by 99
A stacked contractive denoising auto-encoder for ECG signal denoising
Xiong, P., Wang, H., Liu, M., Lin, F., Hou, Z., & Liu, X. (2016) · Physiological Measurement · doi:10.1088/0967-3334/37/12/2214 · Cited by 94
Influence of Electrode Placement on Signal Quality for Ambulatory Pregnancy Monitoring
Rooijakkers, M. J., Song, S., Rabotti, C., Oei, S. G., Bergmans, J. W. M., Cantatore, E., & Mischi, M. (2014) · Computational and Mathematical Methods in Medicine · doi:10.1155/2014/960980 · Cited by 85
Luo, Y., Hargraves, R. H., Belle, A., Bai, O., Qi, X., Ward, K. R., Pfaffenberger, M. P., & Najarian, K. (2013) · The Scientific World JOURNAL · doi:10.1155/2013/896056 · Cited by 63
ECG De-Noising using improved thresholding based on Wavelet transforms
Reddy, G. U., Muralidhar, M., & Varadarajan, S. (2009) · Cited by 59
Cited by
Hong, S., Zhou, Y., Shang, J., Xiao, C., & Sun, J. (2020) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2020.103801 · Cited by 464
Review of noise removal techniques in ECG signals
Chatterjee, S., Thakur, R. S., Yadav, R. N., Gupta, L., & Raghuvanshi, D. K. (2020) · IET Signal Processing · doi:10.1049/iet-spr.2020.0104 · Cited by 333
A survey and analysis of intrusion detection models based on CSE-CIC-IDS2018 Big Data
Leevy, J. L., & Khoshgoftaar, T. M. (2020) · Journal of Big Data · doi:10.1186/s40537-020-00382-x · Cited by 264
Chen, J., Yi, C., Okegbile, S. D., Cai, J., & Shen, X. (2024) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2023.3308717 · Cited by 254
Chuang, C.-H., Chang, K.-Y., Huang, C.-S., & Jung, T.-P. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2022.119586 · Cited by 88
Metadata
- Authors
- Chiang, H.-T., Hsieh, Y.-Y., Fu, S.-W., Hung, K.-H., Tsao, Y., & Chien, S.-Y.
- Venue
- IEEE Access
- Published
- 2019
- Volume
- 7
- Pages
- 60806-60813
- ISSN
- 2169-3536 (ISSN-L)
- OpenAlex
- W2945801048
- Cited by
- 363
- References
- 30
- FWCI
- 20.21
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.