Electrification of the transportation sector can play a vital role in reshaping smart cities. With an increasing number of electric vehicles (EVs) on the road, deployment of well-planned and efficient charging infrastructure is highly desirable. Unlike level 1 and level 2 charging stations, level 3 chargers are super-fast in charging EVs. However, their installation at every possible site is not techno-economically justifiable because level 3 chargers may cause violation of critical system parameters due to their high power consumption. In this paper, we demonstrate an optimized combination of all three types of EV chargers for efficiently managing the EV load while minimizing installation cost, losses, and distribution transformer loading. Effects of photovoltaic (PV) generation are also incorporated in the analysis. Due to the uncertain nature of vehicle users, EV load is modeled as a stochastic process. Particle swarm optimization (PSO) is used to solve the constrained nonlinear stochastic problem. MATLAB and OpenDSS are used to simulate the model. The proposed idea is validated on the real distribution system of the National University of Sciences and Technology (NUST) Pakistan. Results show that an optimized combination of chargers placed at judicious locations can greatly reduce cost from $3.55 million to $1.99 million, daily losses from 787kWh to 286kWh and distribution transformer congestion from 58% to 22% when compared to scenario of optimized placement of level 3 chargers for 20% penetration level in commercial feeders. In residential feeder, these statistics are improved from $2.52 to $0.81 million, from 2167kWh to 398kWh and from 106% to 14%, respectively. It is also realized that the integration of PV improves voltage profile and reduces the negative impact of EV load. Our optimization model can work for commercial areas such as offices, university campuses, and industries as well as residential colonies.

Overview

CoChat Summary

TL;DR

This paper optimizes the placement and mix of Level 1, Level 2, and Level 3 EV chargers in an active distribution network using particle swarm optimization, stochastic EV load modeling, and PV generation. Tested on the NUST Pakistan distribution system, the optimized mix reduces cost, daily losses, and transformer congestion compared with optimized Level 3-only placement.

Key findings

  • In commercial feeders at 20% EV penetration, the optimized charger mix reduced cost from $3.55 million to $1.99 million, daily losses from 787 kWh to 286 kWh, and distribution transformer congestion from 58% to 22% compared with optimized Level 3-only placement.
  • In the residential feeder, the same comparison improved cost from $2.52 million to $0.81 million, daily losses from 2167 kWh to 398 kWh, and transformer utilization from 106% to 14%.
  • Loss reductions for the proposed solution versus Level 3 chargers were 37% (45%) at 5% penetration in commercial (residential) feeders, 54% (63%) at 10% (20%) in commercial feeders, and 61% (82%) at 10% (20%) in the residential feeder.
  • PV integration improved voltage profile: at peak load, voltage improvement was 0.001 per unit at node 20 and 0.005 per unit at node 24; node 41 dropped to 0.93 per unit without PV. The proposed solution maintained commercial feeder voltage above 0.94 per unit for all studied penetration levels and residential voltage at 0.99 per unit, while Level 3 chargers caused residential voltage to drop below 0.975 per unit at peak for 20% penetration.

Methods

  • EV load was modeled stochastically from a 300-sample survey of arrival time, departure time, and traveled distance; probability distributions were fitted in MATLAB, and initial state of charge was related to traveled distance. PV generation was modeled using real insolation and temperature data.
  • The optimization objective minimized charger installation cost, parking-availability penalty, and power-loss cost at $0.092/kWh, subject to voltage limits (±10%), thermal limits, charging capacity, charger-number limits, integer charger counts, and a customer-satisfaction constraint requiring charge above 80% within available time. PSO was implemented in MATLAB and coupled with OpenDSS for unbalanced distribution power flow.
  • The test system was the real 11/0.4 kV radial distribution network of NUST, Islamabad, Pakistan, with three feeders (Feeders 1 and 2 commercial, Feeder 3 residential). The EV modeled was a Nissan Altra with a 29.07 kWh Li-ion battery and about 80-mile range; PV included 200 kW at node 19 of Feeder 1 and 1 MW at node 24 of Feeder 2.

Limitations

  • The paper states that PSO is a heuristic technique and can get stuck in local optima; to mitigate this, PSO was run multiple times and results analyzed statistically, which increases computational burden.
  • The paper states that vehicle-to-grid (V2G) is not considered, and the maximum number of chargers per node is based on an assumed physical limit of 3 allowable parking slots per location.
  • Evident from the text: the EV load model relies on a 300-person survey and one real distribution system (NUST Pakistan), and simulations use one EV type (Nissan Altra), which may limit generalizability to other locations, populations, and vehicle fleets.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1109/access.2020.2984127

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Image 1
CC-BY · From the PDF
FIGURE 2 Per kW solar panels generation.
FIGURE 2 Per kW solar panels generation.CC-BY · From the PDF
FIGURE 3 Flow chart of the optimization algorithm.
FIGURE 3 Flow chart of the optimization algorithm.CC-BY · From the PDF
FIGURE 4 Single line diagram of simulated distribution system.
FIGURE 4 Single line diagram of simulated distribution system.CC-BY · From the PDF
FIGURE 5 Daily system losses for level 3 chargers and proposed solution.
FIGURE 5 Daily system losses for level 3 chargers and proposed solution.CC-BY · From the PDF
FIGURE 6 Maximum transformer utilization for level 3 chargers and proposed solution.
FIGURE 6 Maximum transformer utilization for level 3 chargers and proposed solution.CC-BY · From the PDF
FIGURE 7 Cost of installation of charging stations for level 3 chargers and proposed solution.
FIGURE 7 Cost of installation of charging stations for level 3 chargers and proposed solution.CC-BY · From the PDF
FIGURE 8 Daily voltage profile of commercial feeder (a) Daily voltage profile of commercial feeder node 20 (b) Daily voltage profile of commercial feeder node 41.
FIGURE 8 Daily voltage profile of commercial feeder (a) Daily voltage profile of commercial feeder node 20 (b) Daily voltage profile of commercial feeder node 41.CC-BY · From the PDF
FIGURE 9 Daily voltage profile of commercial feeder node 24.
FIGURE 9 Daily voltage profile of commercial feeder node 24.CC-BY · From the PDF
FIGURE 10 Daily voltage profile of residential feeder node 58 for level 3 chargers and proposed solution.
FIGURE 10 Daily voltage profile of residential feeder node 58 for level 3 chargers and proposed solution.CC-BY · From the PDF
FIGURE 11 Daily voltage profile of commercial feeder node 41 for level 3 chargers and proposed solution.
FIGURE 11 Daily voltage profile of commercial feeder node 41 for level 3 chargers and proposed solution.CC-BY · From the PDF
Image 12
CC-BY · From the PDF
Image 13
CC-BY · From the PDF
Image 14
CC-BY · From the PDF
Image 15
CC-BY · From the PDF
Image 16
CC-BY · From the PDF
Image 17
CC-BY · From the PDF
Image 18
CC-BY · From the PDF
Image 19
CC-BY · From the PDF

Verification

Claims the paper makes

0 Valid · 6 Not valid · 14 Not checked · 62 Own results and interpretations

45 more claims

Create a free account to see all 82 claims and to verify the 2 references still open.

See all claims — free account
  • The quote only partly states this claim. 3
  • It may state two separate claims as one. 17
  • Probably not a substantial claim. 14

Create a free account to see these claims.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

2 of 2

Citations

Cites

Research works printed but not linked: 3

  1. Atlas, 2020, Tier 1 Solar Measurement Site in NUST Islamabad Pakistan
  2. Company, 2019, Tariff Guide
  3. Dugan, 2017, OpenDSS Circuit Solution Technique

Cited by

See all 263

Metadata

Authors
Zeb, M. Z., Imran, K., Khattak, A., Janjua, A. K., Pal, A., Nadeem, M., Zhang, J., & Khan, S.
Affiliations
  • National University of Sciences and Technology (PK)
  • Arizona State University (US)
  • Clemson University (US)
  • AIT Austrian Institute of Technology GmbH (AT)
Venue
IEEE Access
Published
2020
Volume
8
Pages
68124-68134
ISSN
2169-3536 (ISSN-L)
OpenAlex
W3015098507
Cited by
263
References
28
Citations by year
2026: 37 · 2025: 47 · 2024: 64 · 2023: 55 · 2022: 34 · 2021: 23 · 2020: 3
FWCI
9.86
Type
journal article
Language
en
Open access
Locations
  • IEEE Access (publishedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
Arizona State University
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Vehicles and Infrastructure
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Optimal Power Flow Distribution
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Smart Grid Energy Management
Keywords
electric vehicle charging stations, charging station location, active distribution networks, photovoltaic integration, particle swarm optimization, distribution transformer loading, power losses, installation cost minimization, voltage profile, OpenDSS

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-10-28, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-28 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.