The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Parallel operation of single phase inverter modules with no control interconnections
Abstract
To provide reliable power under scheduled and unscheduled outages requires an uninterruptible power supply (UPS) which can be easily expanded to meet the needs of a growing demand. A system suck as this should also be fault tolerant and include the capability for redundancy. These goals can be met by paralleling together smaller inverters if a control scheme can be designed to allow them to operate independently yet still share the load. We have developed a control technique for operating two or more single phase inverter modules in parallel with no auxiliary interconnections. This technique uses frequency, fundamental voltage, and harmonic voltage droop to allow independent inverters to share the load in proportion to their capacities. Simulation results are provided to prove the concept.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Control of parallel connected inverters in standalone AC supply systems
Chandorkar, M. C., Divan, D. M., & Adapa, R. (1993) · IEEE Transactions on Industry Applications · doi:10.1109/28.195899 · Cited by 1,766
Cited by
Guerrero, J. M., Chandorkar, M., Lee, T.-L., & Loh, P. C. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2194969 · Cited by 1,976
A Voltage and Frequency Droop Control Method for Parallel Inverters
De Brabandere, K., Bolsens, B., Van den Keybus, J., Woyte, A., Driesen, J., & Belmans, R. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.900456 · Cited by 1,865
Hierarchical Structure of Microgrids Control System
Bidram, A., & Davoudi, A. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2012.2197425 · Cited by 1,515
Output Impedance Design of Parallel-Connected UPS Inverters With Wireless Load-Sharing Control
Guerrero, J. M., GarciadeVicuna, L., Matas, J., Castilla, M., & Miret, J. (2005) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2005.851634 · Cited by 1,221
Guerrero, J. M., Matas, J., Garcia de Vicuna, L., Castilla, M., & Miret, J. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.892621 · Cited by 1,085
Guerrero, J. M., GarciadeVicuna, L., Matas, J., Castilla, M., & Miret, J. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.833451 · Cited by 1,039
Review of Power Sharing Control Strategies for Islanding Operation of AC Microgrids
Han, H., Hou, X., Yang, J., Wu, J., Su, M., & Guerrero, J. M. (2016) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2434849 · Cited by 988
Anand, S., Fernandes, B. G., & Guerrero, J. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2215055 · Cited by 920
Robust Droop Controller for Accurate Proportional Load Sharing Among Inverters Operated in Parallel
Zhong, Q.-C. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2146221 · Cited by 890
Synchronization and power sharing for droop-controlled inverters in islanded microgrids
Simpson-Porco, J. W., Dörfler, F., & Bullo, F. (2013) · Automatica · doi:10.1016/j.automatica.2013.05.018 · Cited by 832
Review of Active and Reactive Power Sharing Strategies in Hierarchical Controlled Microgrids
Han, Y., Li, H., Shen, P., Coelho, E. A. A., & Guerrero, J. M. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2569597 · Cited by 808
Design, Analysis, and Real-Time Testing of a Controller for Multibus Microgrid System
Li, Y., Vilathgamuwa, D. M., & Loh, P. C. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.833456 · Cited by 723
Control of Distributed Uninterruptible Power Supply Systems
Guerrero, J. M., Hang, L., & Uceda, J. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.924173 · Cited by 700
Wireless-Control Strategy for Parallel Operation of Distributed-Generation Inverters
Guerrero, J. M., Matas, J., Garcia De Vicunagarcia De Vicuna, L., Castilla, M., & Miret, J. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.882015 · Cited by 662
Small-signal stability for parallel-connected inverters in stand-alone AC supply systems
Coelho, E. A. A., Cortizo, P. C., & Garcia, P. F. D. (2002) · IEEE Transactions on Industry Applications · doi:10.1109/28.993176 · Cited by 662
A review of droop control techniques for microgrid
Tayab, U. B., Roslan, M. A. B., Hwai, L. J., & Kashif, M. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.03.028 · Cited by 512
Kim, J., Guerrero, J. M., Rodriguez, P., Teodorescu, R., & Nam, K. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2091685 · Cited by 507
Control of Distributed Generation Systems— Part II: Load Sharing Control
Marwali, M. N., Jung, J.-W., & Keyhani, A. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.836634 · Cited by 438
General aspects, hierarchical controls and droop methods in microgrids: A review
Planas, E., Gil-de-Muro, A., Andreu, J., Kortabarria, I., & Martínez de Alegría, I. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2012.09.032 · Cited by 318
3C strategy for inverters in parallel operation achieving an equal current distribution
Wu, T.-F., Chen, Y.-K., & Huang, Y.-H. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.836342 · Cited by 269
Liquid air energy storage: potential and challenges of hybrid power plants
Antonelli, M., Barsali, S., Desideri, U., Giglioli, R., Paganucci, F., & Pasini, G. (2017) · Applied Energy · doi:10.1016/j.apenergy.2016.11.091 · Cited by 155
A review of control techniques for inverter-based distributed energy resources applications
Hasheminasab, S., Alzayed, M., & Chaoui, H. (2024) · Energies · doi:10.3390/en17122940 · Cited by 56
Metadata
- Authors
- Tuladhar, A., Jin, H., Unger, T., & Mauch, K.
- Venue
- Proceedings of APEC 97 - Applied Power Electronics Conference
- Publisher
- IEEE
- Published
- 2002-11-22
- Volume
- 1
- Pages
- 94-100
- OpenAlex
- W1654140683
- Cited by
- 315
- References
- 1
- FWCI
- 19.56
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.