The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Robust Droop Controller for Accurate Proportional Load Sharing Among Inverters Operated in Parallel
Abstract
In this paper, the inherent limitations of the conventional droop control scheme are revealed. It has been proven that parallel-operated inverters should have the same per-unit impedance in order for them to share the load accurately in proportion to their power ratings when the conventional droop control scheme is adopted. The droop controllers should also generate the same voltage set-point for the inverters. Both conditions are difficult to meet in practice, which results in errors in proportional load sharing. An improved droop controller is then proposed to achieve accurate proportional load sharing without meeting these two requirements and to reduce the load voltage drop due to the load effect and the droop effect. The load voltage can be maintained within the desired range around the rated value. The strategy is robust against numerical errors, disturbances, noises, feeder impedance, parameter drifts and component mismatches. The only sharing error, which is quantified in this paper, comes from the error in measuring the load voltage. When there are errors in the voltage measured, a fundamental tradeoff between the voltage drop and the sharing accuracy appears. It has also been explained that, in order to avoid errors in power sharing, the global settings of the rated voltage and frequency should be accurate. Experimental results are provided to verify the analysis and design.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guerrero, J. M., Vasquez, J. C., Matas, J., de Vicuna, L. G., & Castilla, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2066534 · Cited by 5,075
Synchronverters: Inverters That Mimic Synchronous Generators
Zhong, Q.-C., & Weiss, G. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2048839 · Cited by 3,107
Self-citationLasseter, R. H. (2003) · 2002 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.02CH37309) · doi:10.1109/pesw.2002.985003 · Cited by 1,997
A Voltage and Frequency Droop Control Method for Parallel Inverters
De Brabandere, K., Bolsens, B., Van den Keybus, J., Woyte, A., Driesen, J., & Belmans, R. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.900456 · Cited by 1,865
Control of parallel connected inverters in standalone AC supply systems
Chandorkar, M. C., Divan, D. M., & Adapa, R. (1993) · IEEE Transactions on Industry Applications · doi:10.1109/28.195899 · Cited by 1,766
Mohamed, Y., & El-Saadany, E. F. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2005100 · Cited by 1,230
Output Impedance Design of Parallel-Connected UPS Inverters With Wireless Load-Sharing Control
Guerrero, J. M., GarciadeVicuna, L., Matas, J., Castilla, M., & Miret, J. (2005) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2005.851634 · Cited by 1,221
Li, Y. W., & Kao, C.-N. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2022828 · Cited by 1,127
Guerrero, J. M., Matas, J., Garcia de Vicuna, L., Castilla, M., & Miret, J. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.892621 · Cited by 1,085
Yao, W., Chen, M., Matas, J., Guerrero, J. M., & Qian, Z.-M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2046001 · Cited by 844
Cited by
Liu, J., Miura, Y., & Ise, T. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2465852 · Cited by 1,243
Lu, X., Guerrero, J. M., Sun, K., & Vasquez, J. C. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2266419 · Cited by 1,049
Review of Power Sharing Control Strategies for Islanding Operation of AC Microgrids
Han, H., Hou, X., Yang, J., Wu, J., Su, M., & Guerrero, J. M. (2016) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2434849 · Cited by 988
Synchronization and power sharing for droop-controlled inverters in islanded microgrids
Simpson-Porco, J. W., Dörfler, F., & Bullo, F. (2013) · Automatica · doi:10.1016/j.automatica.2013.05.018 · Cited by 832
Schiffer, J., Seel, T., Raisch, J., & Sezi, T. (2016) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2015.2420622 · Cited by 450
Metadata
- Authors
- Zhong, Q.-C.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2013-04
- Volume
- 60
- Issue
- 4
- Pages
- 1281-1290
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2096928643
- Cited by
- 890
- References
- 23
- FWCI
- 54.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Robust Droop Controller for Accurate Proportional Load Sharing Among Inverters Operated in Parallel. https://app.cochat.ai/papers/10.1109/tie.2011.2146221
- The paper
- Zhong, Q.-C. (2013). Robust Droop Controller for Accurate Proportional Load Sharing Among Inverters Operated in Parallel. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2011.2146221
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.