Review on protection coordination strategies and development of an effective protection coordination system for DC microgrid
The DOI matches its Crossref record.
Abstract
In this paper, common DC-fault detection methods have been reviewed. Effects of two line-to-line and line-to-ground fault types from various fault locations to operation of the DC system are presented. In addition, operation principle, strong and weak points of four main types of protection devices (including fuses, no-fuse circuit breakers, power-electronic protection devices and protective relays) are mentioned. Each different type of protection devices has the ability to protect and isolate different components of the DC microgrid (e.g. power converter, PV system, battery system, capacitor and others) under fault occurrences. The paper analyses possible protection coordination strategies of protection devices to ensure safety of any components in the DC microgrid. These summarized coordination strategies can be suitable for any DC microgrid configurations. In the next content, an effective protection coordination system of a real community-sized DC microgrid is developed, which use fast-acting fuses to replace no-fuse circuit breakers already installed at some certain locations in the DC microgrid. Aims of this improved protection coordination system are to shorten critical fault clearing time and get the cost effectiveness while still ensuring high selectivity, dependability and safety of the DC microgrid. As a result, the no-fuse circuit breakers placed at locations such as: output of PV arrays, output of the battery, output of the fuel-cell system, and terminals of power converters are efficiently replaced by the fast-acting fuses. Additionally, protection devices located at load feeders are suggested to use the relays to optimise the coordination time between main and back-up protection in case of faults occurring at the load feeders.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Extreme Fast Charging of Electric Vehicles: A Technology Overview
Tu, H., Feng, H., Srdic, S., & Lukic, S. (2019) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2019.2958709 · Cited by 898
Acharige, S. S. G., Haque, M. E., Arif, M. T., Hosseinzadeh, N., Hasan, K. N., & Oo, A. M. T. (2023) · IEEE Access · doi:10.1109/access.2023.3267164 · Cited by 590
Khalid, M. R., Khan, I. A., Hameed, S., Asghar, M. S. J., & Ro, J. (2021) · IEEE Access · doi:10.1109/access.2021.3112189 · Cited by 353
Ali, Z., Terriche, Y., Hoang, L. Q. N., Abbas, S. Z., Hassan, M. A., Sadiq, M., Su, C.-L., & Guerrero, J. M. (2021) · IEEE Access · doi:10.1109/access.2021.3112383 · Cited by 104
“The authors in [45]–[48]; have summarized the protection challenges and issues in DC MGs, while the authors in [49], [50] have addressed the challenges of DC fault protection and reconfiguration issues.”
BackgroundAdaptive Coordinated Protection for DC Microgrids With Lunar Surface Power Applications
Carbone, M. A., Muscatello, M., Collazo Fernandez, X., Gardner, B., & Csank, J. (2025) · IEEE Access · doi:10.1109/access.2025.3593439 · Cited by 5
“Bui [9] proposes a method for coordinated protection of DC microgrids relying on fuses to break the DC fault current.”
Metadata
- Authors
- Bui, D. M., Chen, S.-L., Wu, C.-H., Lien, K.-Y., Huang, C.-H., & Jen, K.-K.
- Venue
- 2014 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)
- Publisher
- IEEE
- Published
- 2014-12
- Pages
- 1-10
- OpenAlex
- W1585350532
- Cited by
- 69
- References
- 0
- FWCI
- 6.48
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.