A CMOS-based sensor array for in-vitro neural tissue interfacing with 4225 recording sites and 1024 stimulation sites
The DOI matches its Crossref record.
Abstract
A CMOS-based microelectrode array (MEA) with 4225 recording sites and 1024 stimulation sites and a related data acquisition system are presented. The chip provides high spatiotemporal resolution on an active area of 1 mm × 1 mm or 2 mm × 2 mm, respectively, and allows in-vitro neural tissue interfacing experiments with full imaging capability. The entire chip surface is covered by a thin high-k dielectric layer so that electric coupling between biological tissue and solid-state chip is purely capacitive. Biological experiments reveal proper functionality of the system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Yger, P., Spampinato, G. L., Esposito, E., Lefebvre, B., Deny, S., Gardella, C., Stimberg, M., Jetter, F., Zeck, G., Picaud, S., et al. (2018) · eLife · doi:10.7554/elife.34518 · Cited by 441
Self-citationHigh-resolution CMOS MEA platform to study neurons at subcellular, cellular, and network levels
Müller, J., Ballini, M., Livi, P., Chen, Y., Radivojevic, M., Shadmani, A., Viswam, V., Jones, I. L., Fiscella, M., Diggelmann, R., et al. (2015) · Lab on a Chip · doi:10.1039/c5lc00133a · Cited by 326
Dragas, J., Viswam, V., Shadmani, A., Chen, Y., Bounik, R., Stettler, A., Radivojevic, M., Geissler, S., Obien, M. E. J., Muller, J., et al. (2017) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2017.2686580 · Cited by 209
“two most common CMOS-MEA architectures base either on the in-pixel front-end amplifiers [18]–[20], or on the switch matrix [17], [21], where the amplifiers reside outside of the electrode array and are connected to the electrodes via a programmable matrix of switches.”
Petrini, G., Moreva, E., Bernardi, E., Traina, P., Tomagra, G., Carabelli, V., Degiovanni, I. P., & Genovese, M. (2020) · Advanced Quantum Technologies · doi:10.1002/qute.202000066 · Cited by 63
Yuan, X., Hierlemann, A., & Frey, U. (2021) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2021.3066043 · Cited by 50
Shadmani, A., Viswam, V., Chen, Y., Bounik, R., Dragas, J., Radivojevic, M., Geissler, S., Sitnikov, S., Muller, J., & Hierlemann, A. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2890530 · Cited by 24
“While most of the stimulation circuits are based on either voltage-controlled [34], [41], [42] or”
Corna, A., Ramesh, P., Jetter, F., Lee, M.-J., Macke, J. H., & Zeck, G. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac0679 · Cited by 18
“A solution of this problem is offered by high-density MEAs, with electrode distances in the order of ∼10–20 μm [22, 47].”
BackgroundMethodSelf-citation
Metadata
- Authors
- Bertotti, G., Velychko, D., Dodel, N., Keil, S., Wolansky, D., Tillak, B., Schreiter, M., Grall, A., Jesinger, P., Rohler, S., Eickenscheidt, M., Stett, A., Moller, A., Boven, K.-H., Zeck, G., & Thewes, R.
- Venue
- 2014 IEEE Biomedical Circuits and Systems Conference (BioCAS) Proceedings
- Publisher
- IEEE
- Published
- 2014-10
- Pages
- 304-307
- OpenAlex
- W2040793024
- Cited by
- 64
- References
- 0
- FWCI
- 22.63
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.