Tremor frequency based filter to extract voluntary movement of patients with essential tremor
The DOI matches its Crossref record; 26 of the 28 references it cites were found in a registry or an index.
Abstract
Essential Tremor (ET) refers to involuntary oscillations of a part of the body. ET patients face serious difficulties in performing daily living activities. Our motivation is to develop a system that can enable ET patients to perform their daily living activities; hence we have been developing a myoelectric controlled exoskeletal robot for ET patients. However, the EMG signal of ET patients contains not only voluntary movement signals but also tremor signals. Accordingly, to control this robot correctly, tremor signals must be removed from the EMG signal of ET patients. To date, we have been developing a filter to remove tremor signals, which has been largely effective in this. However, tremor signals are generated both while voluntary movement is being performed and while a posture is being maintained, and the filter ended up attenuating both these signals. But, to control this robot accurately, the signal generated during performance of voluntary movement is expected not to be attenuated. Therefore, in this paper, we propose a method that attenuates only tremor signals arising during maintenance of a posture. To accomplish this objective, we focus on the frequency of tremor signals. From the experiment, we confirmed the characteristic that the frequency of tremor signals changed depending on the state of the patient's movement. We then used frequency as a switch to activate the previously proposed filter by setting a threshold. As an evaluation, signals processed by the proposed method were input to a time delay neural network. The proposed method succeeded in partly improving recognition due to reduction of attenuation during performance of voluntary movement. However, the proposed method failed recognition in cases where the frequency of tremor signals varied widely. As a future work we will review the method to calculate the frequency of tremor signals and improve recognition.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Phoneme recognition using time-delay neural networks
Waibel, A., Hanazawa, T., Hinton, G., Shikano, K., & Lang, K. J. (1989) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/29.21701 · Cited by 2,643
Control of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal
Zecca, M., Micera, S., Carrozza, M. C., & Dario, P. (2002) · Critical Reviews? in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v30.i456.80 · Cited by 606
Control of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal
Zecca, M., Micera, S., Carrozza, M. C., & Dario, P. (2017) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v45.i1-6.150 · Cited by 570
Deuschl, G., Raethjen, J., Lindemann, M., & Krack, P. (2001) · Muscle & Nerve · doi:10.1002/mus.1063 · Cited by 508
Design and Validation of a Rehabilitation Robotic Exoskeleton for Tremor Assessment and Suppression
Rocon, E., Belda-Lois, J. M., Ruiz, A. F., Manto, M., Moreno, J. C., & Pons, J. L. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903917 · Cited by 349
Toward active tremor canceling in handheld microsurgical instruments
Riviere, C. N., Ang, W. T., & Khosla, P. K. (2003) · IEEE Transactions on Robotics and Automation · doi:10.1109/tra.2003.817506 · Cited by 245
The application of neural networks to myoelectric signal analysis: a preliminary study
Kelly, M. F., Parker, P. A., & Scott, R. N. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.52324 · Cited by 221
A log-linearized Gaussian mixture network and its application to EEG pattern classification
Tsuji, T., Fukuda, O., Ichinobe, H., & Kaneko, M. (1999) · IEEE Transactions on Systems Man and Cybernetics Part C (Applications and Reviews) · doi:10.1109/5326.740670 · Cited by 149
Tremor disorders. Diagnosis and management.
Anouti, A., & Koller, W. C. (1995) · PubMed Central · Cited by 135
Efficient cepstral normalization for robust speech recognition
Liu, F., Stern, R. M., Huang, X., & Acero, A. (1993) · DARPA Workshop on Speech and Natural Language (HLT) · doi:10.3115/1075671.1075688 · Cited by 135
Pathological tremor management: modelling, compensatory technology and evaluation
Rocon, E., Belda-Lois, J. M., Sanchez-Lacuesta, J. J., & Pons, J. L. (2004) · Technology and Disability · doi:10.3233/tad-2004-16102 · Cited by 89
EMG-Based Neuro-Fuzzy Control of a 4DOF Upper-Limb Power-Assist Exoskeleton
Kiguchi, K., Imada, Y., & Liyanage, M. (2007) · 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2007.4352969 · Cited by 67
Journee, H. L. (1983) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1983.325120 · Cited by 56
The effect of inertial loading on wrist postural tremor in essential tremor
Héroux, M. E., Pari, G., & Norman, K. E. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.03.012 · Cited by 55
Wearable handling support system for paralyzed patient
Hasegawa, Y., Mikami, Y., Watanabe, K., Firouzimehr, Z., & Sankai, Y. (2008) · 2008 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2008.4651199 · Cited by 47
A discrimination system using neural network for EMG-controlled prostheses
Kuribayashi, K., Okimura, K., & Taniguchi, T. (2003) · IEEE International Workshop on Robot and Human Communication (RO-MAN) · doi:10.1109/roman.1992.253914 · Cited by 41
An EMG controlled human supporting robot using neural network
Fukuda, O., Tsuji, T., Shigeyoshi, H., & Kaneko, M. (2003) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.1999.811705 · Cited by 32
FES-controlled co-contraction strategies for pathological tremor compensation
Bo, A. P. L., Poignet, P., Zhang, D., & Ang, W. T. (2009) · 2009 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2009.5354397 · Cited by 30
Tremor attenuation using FES-based joint stiffness control
Bó, A. P. L., & Poignet, P. (2010) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2010.5509560 · Cited by 26
Tremor suppression control of Meal-Assist Robot with adaptive filter
Ohara, E., Yano, K., Horihata, S., Aoki, T., & Nishimoto, Y. (2009) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2009.5209565 · Cited by 26
Development of robotic upper limb orthosis with tremor suppressiblity and elbow joint movability
Seki, M., Matsumoto, Y., Ando, T., Kobayashi, Y., Fujie, M. G., Iijima, H., & Nagaoka, M. (2011) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/icsmc.2011.6083728 · Cited by 24
Self-citationEstimation of instantaneous tremor parameters for FES-based tremor suppression
Gallego, J. Á., Rocón, E., & Pons, J. L. (2010) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2010.5509663 · Cited by 15
Development of tremor-suppression filter for meal-assist robot
Ohara, E., Yano, K., Horihata, S., Aoki, T., & Nishimoto, Y. (2009) · IEEE World Haptics Conference (WHC) · doi:10.1109/whc.2009.4810802 · Cited by 15
Intelligent Trunk Corset to Support Rollover of Cancer Bone Metastasis Patients
Andõ, T., Kobayashi, Y., Okamoto, J., et al. (2010) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2010.2040833 · Cited by 12
Self-citationAndõ, T., Okamoto, J., & Fujie, M. G. (2008) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2008.4650770 · Cited by 11
Self-citationThe weight load inconsistency effect on voluntary movement recognition of essential tremor patient
Seki, M., Matsumoto, Y., Ando, T., Kobayashi, Y., Iijima, H., Nagaoka, M., & Fujie, M. G. (2011) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2011.6181402 · Cited by 9
Self-citation
Research works printed but not linked: 4
- seki, 2011, Development of Essential Tremor Noise Suppression Filter for Voluntary Movement Extraction from Surface EMG
- oosawa, 1989, Clinical Applications in Surface Electromyography, 59, 499
- hirose, 1992, Text of electromyography, Bunkoudo
- elble, 1990, Tremor Baltimore
Cited by
Ison, M., & Artemiadis, P. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/5/051001 · Cited by 225
“Despite the lack of a global optimum solution, threat of overfitting to training data, slow training times, and general underperformance compared to SVMs [187], ANNs have proven to be effective for many myoelectric control schemes [24, 159, 203–207], with backpropagation networks proving robust in real-time control [2…”
BackgroundContinuous Monitoring of Essential Tremor Using a Portable System Based on Smartwatch
Zheng, X., Vieira Campos, A., Ordieres-Meré, J., Balseiro, J., Labrador Marcos, S., & Aladro, Y. (2017) · Frontiers in Neurology · doi:10.3389/fneur.2017.00096 · Cited by 44
“The tasks of FTMTRS (12) included are the following: (1) keeping hands relaxed on the lap for evaluating rest tremor, (2) holding their arms extended horizontally for studying postural tremor, and (3) repeating finger–nose test”
BackgroundMethodWang, J., & Barry, O. (2021) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2021.3061361 · Cited by 24
“The motion planning of r may also be realized through the extraction and prediction of voluntary motion [11], [12].”
BackgroundMethodDevelopment of an Exoskeleton to Support Eating Movements in Patients with Essential Tremor
Matsumoto, Y., Waseda University, 3.-4.-1. O., Seki, M., Ando, T., Kobayashi, Y., Nakashima, Y., Iijima, H., Nagaoka, M., Fujie, M. G., MONOZUKURI Mechatronics Laboratory, K. S. C., et al. (2013) · Journal of Robotics and Mechatronics · doi:10.20965/jrm.2013.p0949 · Cited by 23
Self-citationAnalysis of EMG signals of patients with essential tremor focusing on the change of tremor frequency
Matsumoto, Y., Seki, M., Andõ, T., Kobayashi, Y., Iijima, H., Nagaoka, M., & Fujie, M. G. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346409 · Cited by 22
“To achieve this, we use the tremor signal frequency as a switch to activate the powered sine filter [20].”
MethodSelf-citation
Metadata
- Authors
- Matsumoto, Y., Seki, M., Ando, T., Kobayashi, Y., Iijima, H., Nagaoka, M., & Fujie, M. G.
- Affiliations
- Waseda University (JP)
- Panasonic (Japan) (JP)
- Juntendo University (JP)
- Venue
- 2012 4th IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob)
- Publisher
- IEEE
- Published
- 2012-06
- Volume
- 59
- Pages
- 1415-1422
- ISSN
- 2155-1774 (ISSN-L)
- OpenAlex
- W2160462084
- Semantic Scholar
- 85e3ca5045d6e51669b6933611bed8e76d1e1807
- Cited by
- 16
- References
- 28
- Citations by year
- 2021: 4 · 2019: 1 · 2017: 2 · 2016: 1 · 2015: 1 · 2014: 4 · 2013: 2 · 2012: 1
- FWCI
- 5.50
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Keywords
- essential tremor, tremor frequency, EMG signal processing, myoelectric control, voluntary movement, posture maintenance, time-delay neural networks, assistive robotics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.