CoChat

Determining the Single Best Axis for Exercise Repetition Recognition and Counting on SmartWatches

Mortazavi, Bobak Jack, Pourhomayoun, Mohammad, Alsheikh, Gabriel, Alshurafa, Nabil, Lee, Sunghoon Ivan, Sarrafzadeh, Majid · 2014 · 2014 11th International Conference on Wearable and Implantable Body Sensor Networks
Cited by 63

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

Due to the exploding costs of chronic diseasesstemming from physical inactivity, wearable sensor systems toenable remote, continuous monitoring of individuals has increasedin popularity. Many research and commercial systems exist inorder to track the activity levels of users from general dailymotion to detailed movements. This work examines this problemfrom the space of smartwatches, using the Samsung GalaxyGear, a commercial device containing an accelerometer and agyroscope, to be used in recognizing physical activity. This workalso shows the sensors and features necessary to enable suchsmartwatches to accurately count, in real-time, the repetitions offree-weight and body-weight exercises. The goal of this work isto try and select only the best single axis for each activity byextracting only the most informative activity-specific features, inorder to minimize computational load and power consumptionin repetition counting. The five activities are incorporated in aworkout routine, and knowing this information, a random forestclassifier is built with average area under the curve (AUC) of: 974, with average accuracy of 93%, in cross validation to identify eachrepetition of a given exercise using all available sensors and AUCof: 950 with accuracy of 89:9% using the single best axis foreach activity alone. Adding a gyroscope with the accelerometerincreased the average AUC from: 968 to: 974, increasing theaccuracy of specific movements as much as 2%. Results show that, while a combination of accelerometer and gyroscope provide thestrongest classification results, often times features extracted froma single, best axis are enough to accurately identify movementsfor a personal training routine, where that axis is often, but notalways, an accelerometer axis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/bsn.2014.21

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 63

Metadata

Authors
Mortazavi, B. J., Pourhomayoun, M., Alsheikh, G., Alshurafa, N., Lee, S. I., & Sarrafzadeh, M.
Venue
2014 11th International Conference on Wearable and Implantable Body Sensor Networks
Publisher
IEEE
Published
2014-06
Pages
33-38
OpenAlex
W2059983432
Cited by
63
References
9
FWCI
3.78
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Determining the Single Best Axis for Exercise Repetition Recognition and Counting on SmartWatches. https://app.cochat.ai/papers/10.1109/bsn.2014.21
The paper
Mortazavi, B. J., Pourhomayoun, M., Alsheikh, G., Alshurafa, N., Lee, S. I., & Sarrafzadeh, M. (2014). Determining the Single Best Axis for Exercise Repetition Recognition and Counting on SmartWatches. 2014 11th International Conference on Wearable and Implantable Body Sensor Networks. https://doi.org/10.1109/bsn.2014.21

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.