A fully-integrated bandpass amplifier for extracellular neural recording
The DOI matches its Crossref record.
Abstract
This paper describes a fully-integrated bandpass amplifier for neural recording applications. Diode-connected sub-threshold-biased NMOS transistors in the feedback loop of the amplifier realize the high on-chip impedance necessary to eliminate the dc baseline potential of the electrode while amplifying neural field and action potentials. The amplifier has an in-band gain of 38.2dB, a dc gain of 0, an upper cutoff frequency of 24kHz and a low frequency cutoff of 66mHz. It consumes 92/spl mu/W from /spl plusmn/1.5V supplies and has an input-referred noise of 16.6/spl mu/Vrms integrated from 100Hz-10kHz. The amplifier occupies 0.082mm/sup 2/ in 3/spl mu/m features and is being used on a 64-site neural recording probe.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656
Self-citationKipke, D. R., Vetter, R. J., Williams, J. C., & Hetke, J. F. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814443 · Cited by 367
Microelectrodes, Microelectronics, and Implantable Neural Microsystems
Wise, K. D., Sodagar, A. M., Yao, Y., Gulari, M. N., Perlin, G. E., & Najafi, K. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2008.922564 · Cited by 335
Self-citationA 200 μW Eight-Channel EEG Acquisition ASIC for Ambulatory EEG Systems
Yazicioglu, R. F., Merken, P., Puers, R., & Van Hoof, C. (2008) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2008.2006462 · Cited by 271
An Implantable 64-Channel Wireless Microsystem for Single-Unit Neural Recording
Sodagar, A. M., Perlin, G. E., Yao, Y., Najafi, K., & Wise, K. D. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2009.2023159 · Cited by 218
“, using no off-chip components) is still relatively limited [37]–[40].”
BackgroundSelf-citation
Metadata
- Authors
- Olsson, R. H. I. I. I., Gulari, A. N., & Wise, K. D.
- Venue
- First International IEEE EMBS Conference on Neural Engineering, 2003. Conference Proceedings.
- Publisher
- IEEE
- Published
- 2003-12-22
- Pages
- 165-168
- ISSN
- 1948-3554 (ISSN-L)
- OpenAlex
- W2107738534
- Cited by
- 55
- References
- 0
- FWCI
- 12.20
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A fully-integrated bandpass amplifier for extracellular neural recording. https://app.cochat.ai/papers/10.1109/cne.2003.1196783
- The paper
- Olsson, R. H. I. I. I., Gulari, A. N., & Wise, K. D. (2003). A fully-integrated bandpass amplifier for extracellular neural recording. First International IEEE EMBS Conference on Neural Engineering, 2003. Conference Proceedings. https://doi.org/10.1109/cne.2003.1196783
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.