Fabrication of multi-layer, high-density micro-electrode arrays for neural stimulation and bio-signal recording
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The electrode-tissue interface is of principal importance in neuroprosthesis. Indeed the successes of the cochlear implant and other therapeutic devices are directly attributable to the design and fabrication techniques of their interfaces with neural tissue, that is, the electrode or electrode array. Traditional fabrication techniques are often labor-intensive and do not lend themselves to automation thereby increasing the cost of the electrode, and owing to fabrication variability, potentially compromising the reliability of the devices incorporating them. Exacerbating the difficulties in electrode fabrication further is the fact that only a handful of materials have been demonstrated to be biologically inert. These same materials are often among the most difficult to utilize in the fabrication of neural electrodes. In the present paper, a new methodology for automated fabrication of high-density electrode arrays is presented. Using exclusively biologically-inert raw materials, laser machining techniques combined with multiple layer structuring is shown to achieve feature sizes of the order of 25 mum. As an illustrative example, a 98 electrode array for interfacing with surviving retinal tissue through a visual prosthesis for the blind is presented. Overall dimensions of the array are of the order of 8.7 times 9.4 mm, consistent with approximately 25 degrees of visual field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078 · cited 1×
“Recently, the authors began the fabrication of micro-machined devices using laser ablation of the noble metal platinum and the silicone elastomer, polydimethylsiloxane (PDMS) as these are established biomaterials [1].”
Background
Cited by
Focal activation of the feline retina via a suprachoroidal electrode array
Wong, Y. T., Chen, S. C., Seo, J. M., Morley, J. W., Lovell, N. H., & Suaning, G. J. (2009) · Vision Research · doi:10.1016/j.visres.2009.02.018 · Cited by 109
Self-citationGiagka, V., & Serdijn, W. A. (2018) · Bioelectronic Medicine · doi:10.1186/s42234-018-0010-y · Cited by 58
Lamont, C., Grego, T., Nanbakhsh, K., Shah Idil, A., Giagka, V, Vanhoestenberghe, A., Cogan, S., & Donaldson, N. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abf0d6 · Cited by 28
“Similar to the methods described in [28], we diluted the MED3-4013 pre-polymer in n-Heptane (99%, Fisher Scientific) to improve its viscosity and allow for dip-coating.”
MethodMicrochannel neural interface manufacture by stacking silicone and metal foil laminae
Lancashire, H. T., Vanhoestenberghe, A., Pendegrass, C. J., Ajam, Y. A., Magee, E., Donaldson, N., & Blunn, G. W. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/034001 · Cited by 13
“5 mm) by vertically separating electrode tracks [18] and can be used to create devices with microfluidic channels [19, 20].”
BackgroundMethod
Metadata
- Authors
- Suaning, G. J., Schuettler, M., Ordonez, J. S., & Lovell, N. H.
- Venue
- 2007 3rd International IEEE/EMBS Conference on Neural Engineering
- Publisher
- IEEE
- Published
- 2007-05
- Pages
- 5-8
- ISSN
- 1948-3554 (ISSN-L)
- OpenAlex
- W2134528703
- Cited by
- 34
- References
- 1
- FWCI
- 9.09
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.