From ICS Attacks' Analysis to the S.A.F.E. Approach: Implementation of Filters Based on Behavioral Models and Critical State Distance for ICS Cybersecurity
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In critical ICS infrastructures, the attack surface encompasses all devices, systems, and protocols used to monitor and control industrial processes. This includes components such as sensors, actuators, PLCs, SCADA systems, DCS, communication networks, and control software [123].”
From A Novel Risk-Based Methodology for Enhancing Industrial Control Systems Security: A Systematic Review and Case Study (2025) · cites this paper as [123]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guide to Industrial Control Systems (ICS) Security
Stouffer, K., Pillitteri, V., Lightman, S., Abrams, M., & Hahn, A. (2015) · doi:10.6028/nist.sp.800-82r2 · Cited by 1,377 · cited 1×
“Industrial Control Systems (ICSs) define the interactions between digital and physical layers in order to achieve an industrial objective, belonging to Operation Technology (OT) field [1].”
BackgroundA survey of intrusion detection techniques for cyber-physical systems
Mitchell, R., & Chen, I.-R. (2014) · ACM Computing Surveys · doi:10.1145/2542049 · Cited by 768 · cited 3×
“Moreover, Mitchell and Chen [32] have formalized techniques based on IDS to adapt them to ICSs.”
BackgroundMethodInfluentialCyber physical systems security: analysis, challenges and solutions
Ashibani, Y., & Mahmoud, Q. H. (2017) · Computers & Security · doi:10.1016/j.cose.2017.04.005 · Cited by 447
The Cybersecurity Landscape in Industrial Control Systems
McLaughlin, S., Konstantinou, C., Wang, X., Davi, L., Sadeghi, A.-R., Maniatakos, M., & Karri, R. (2016) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2512235 · Cited by 391 · cited 4×
“Based on McLaughlin et al. [22], Khorrami et al. [23] and databases [18], Fig.”
BackgroundInfluentialSecurity for Industrial Communication Systems
Dzung, D., Naedele, M., Von Hoff, T. P., & Crevatin, M. (2005) · Proceedings of the IEEE · doi:10.1109/jproc.2005.849714 · Cited by 386
A Multidimensional Critical State Analysis for Detecting Intrusions in SCADA Systems
Carcano, A., Coletta, A., Guglielmi, M., Masera, M., Nai Fovino, I., & Trombetta, A. (2011) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2010.2099234 · Cited by 259 · cited 1×
“Originally designed for continuous variables [34], an adaptation has been made for Discrete-Event System (DES) in [31] by using exploration state algorithm.”
MethodSecurity issues in SCADA based industrial control systems
Babu, B., Ijyas, T., Muneer, P., & Varghese, J. (2017) · 2017 2nd International Conference on Anti-Cyber Crimes (ICACC) · doi:10.1109/anti-cybercrime.2017.7905261 · Cited by 73 · cited 1×
“[13] focus theirs works on network vulnerabilities (code injection, buffer overflow, DOS).”
BackgroundFalse sequential logic attack on SCADA system and its physical impact analysis
Li, W., Xie, L., Deng, Z., & Wang, Z. (2016) · Computers & Security · doi:10.1016/j.cose.2016.01.001 · Cited by 71 · cited 2×
“Random attacks send information without considering the process knowledge, sequential attacks [16], [19] break the sequential logic defined by the control law, false command injections [20] corrupt orders in the control channel and FDI [21] where data is intercepted and spoofed.”
BackgroundSicard, F., Zamai, É., & Flaus, J.-M. (2018) · Diagnosability, Security and Safety of Hybrid Dynamic and Cyber-Physical Systems · doi:10.1007/978-3-319-74962-4_5 · Cited by 10 · cited 10×
“Since the beginning of this century, ICSs are targeted by hackers exploiting their components and architecture vulnerabilities as well as interoperability, to perform cyberattacks [8], [22].”
BackgroundMethodInfluentialSelf-citation
Research works printed but not linked: 27
- sicard, 2017, Cyberdéfense des systèmes de contrôle-commande industriels: une approche par filtres basée sur la distance aux états critiques pour la sécurisation face aux cyberattaques, C&esar 2017
- sicard, 2017, Distance Concept Based Filter Approach for Detection of Cyberattacks on Industrial Control Systems, presented at the IFAC World Congress GdR MACS Young PhD Researchers-Toulouse
- stoler, 2018, Anatomy of the Triton Malware Attack
- villemeur, 1992, Reliability Availability Maintainability and Safety Assessment, 2
- 10.1016/0951-5240(91)90043-X · DOI
- 10.1016/j.procir.2012.07.110 · DOI
- 10.1109/CPRE.2016.7914914 · DOI
- 10.1109/TELFOR.2012.6419513 · DOI
- 10.1109/WCICSS.2016.7882935 · DOI
- 10.1049/iet-cps.2016.0019 · DOI · Paper page
- 0, ICS-CERT/The Industrial Control Systems Cyber Emergency Response Team
- 10.1145/2732198.2732200 · DOI · Paper page
- cherepanov, 2017, A new threat for industrial control systems (WIN32/INDUSTROYER), ESET, 17
- 10.1016/j.procir.2014.03.115 · DOI · Paper page
- bock, 2017, Ukrainian power grids cyberattack, INTECH, 64, 32
- 10.1016/j.rser.2016.01.025 · DOI · Paper page
- 1991, A Reference Model for Computer Integrated Manufacturing (CIM) A Description from the Viewpoint of Industrial Automation
- 0, Schneider Electric Triconex Tricon (Update A) | ICS-CERT
- kamel, 2013, Programmable Logic Controllers-Industrial Control
- 10.1080/23742917.2016.1252211 · DOI · Paper page
- 10.1177/1748006X15623089 · DOI
- gao, 2010, On SCADA control system command and response injection and intrusion detection, ECrime Researchers Summit (eCrime) 2010, 1
- wang, 2014, SRID: State Relation Based Intrusion Detection for False Data Injection Attacks in SCADA, Computer Security - ESORICS 2014, 401, 10.1007/978-3-319-11212-1_23 · DOI
- 10.1109/MSPEC.2013.6471059 · DOI · Paper page
- 10.1109/MDAT.2016.2594178 · DOI
- 10.1109/IECON.2011.6120048 · DOI · Paper page
- falliere, 2011, W32. stuxnet dossier, Symantec Security Response Version 1 4
Cited by
SICARD, F., ZAMAI, É., & FLAUS, J.-M. (2019) · Reliability Engineering & System Safety · doi:10.1016/j.ress.2019.03.020 · Cited by 25
Self-citationDavid Echeverría López, A., Amor Pinilla, M., & Carvajal Mora, H. R. (2025) · IEEE Access · doi:10.1109/access.2025.3609252 · Cited by 1
“This includes components such as sensors, actuators, PLCs, SCADA systems, DCS, communication networks, and control software [123].”
Metadata
- Authors
- Franck, S., Cedric, E., Eric, Z., & Jean-Marie, F.
- Venue
- 2018 2nd Cyber Security in Networking Conference (CSNet)
- Publisher
- IEEE
- Published
- 2018-10
- Pages
- 1-8
- Cited by
- 8
- References
- 9
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: From ICS Attacks' Analysis to the S.A.F.E. Approach: Implementation of Filters Based on Behavioral Models and Critical State Distance for ICS Cybersecurity. https://app.cochat.ai/papers/10.1109/csnet.2018.8602960
- The paper
- Franck, S., Cedric, E., Eric, Z., & Jean-Marie, F. (2018). From ICS Attacks' Analysis to the S.A.F.E. Approach: Implementation of Filters Based on Behavioral Models and Critical State Distance for ICS Cybersecurity. 2018 2nd Cyber Security in Networking Conference (CSNet). https://doi.org/10.1109/csnet.2018.8602960
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.