Powering and communicating with mm-size implants
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
This paper deals with system level design considerations for mm-size implantable electronic devices with wireless connectivity. In particular, it focuses on neural sensors as one application requiring such miniature interfaces. Common to all these implants is the need for power supply and a wireless interface. Wireless power transfer via electromagnetic fields is identified as a promising option for powering such devices. Design methodologies, system level trade-offs, as well as limitations of power supply systems based on electromagnetic coupling are discussed in detail. Further, various wireless data communication architectures are evaluated for their feasibility in the application. Reflective impulse radios are proposed as an alternative scheme for enabling highly scalable data transmission at <;1pJ/bit. Finally, design considerations for the corresponding reader system are addressed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896 · cited 1×
“In some applications neural probes of 10s of mm(2) large are used [2]; in others, much smaller systems are desirable to enable chronic recordings by minimizing micromotion in vivo [3].”
BackgroundChronic, multisite, multielectrode recordings in macaque monkeys
Nicolelis, M. A. L., Dimitrov, D., Carmena, J. M., Crist, R., Lehew, G., Kralik, J. D., & Wise, S. P. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1934665100 · Cited by 740
Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex
Rousche, P. J., & Normann, R. A. (1998) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(98)00031-4 · Cited by 646 · cited 1×
“In some applications neural probes of 10s of mm(2) large are used [2]; in others, much smaller systems are desirable to enable chronic recordings by minimizing micromotion in vivo [3].”
BackgroundOptimal Frequency for Wireless Power Transmission Into Dispersive Tissue
Poon, A. S. Y., O'Driscoll, S., & Meng, T. H. (2010) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2010.2044310 · Cited by 469 · cited 2×
“However, recent research has shown that, for very small receive antenna sizes, the optimum frequency that minimizes the link loss can be significantly higher [9].”
Background
Cited by
Wireless Recording in the Peripheral Nervous System with Ultrasonic Neural Dust
Seo, D., Neely, R. M., Shen, K., Singhal, U., Alon, E., Rabaey, J. M., Carmena, J. M., & Maharbiz, M. M. (2016) · Neuron · doi:10.1016/j.neuron.2016.06.034 · Cited by 557
“…(EM) energy coupling and communication, which becomes extremely inefficient in systems smaller than 5 mm due to the inefficiency of coupling radio waves at these scales within tissue (Rabaey et al., 2011; Seo et al., 2013; see also Size Scaling and Electromagnetics in the Supplemental Information).”
Self-citationOptimal Design of Wireless Power Transmission Links for Millimeter-Sized Biomedical Implants
Ahn, D., & Ghovanloo, M. (2016) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2370794 · Cited by 246
“In [19] and [20] it was suggested that the operating frequencies around 300 MHz and below are optimal for 1 2 mm-sized single-loop square coil.”
BackgroundNeural Dust: An Ultrasonic, Low Power Solution for Chronic Brain-Machine Interfaces
Seo, D., Carmena, J. M., Rabaey, J. M., Alon, E., & Maharbiz, M. M. (2013) · arXiv · doi:10.48550/arxiv.1307.2196 · Cited by 172
Self-citationModel validation of untethered, ultrasonic neural dust motes for cortical recording
Seo, D., Carmena, J. M., Rabaey, J. M., Maharbiz, M. M., & Alon, E. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2014.07.025 · Cited by 158
Self-citationZargham, M., & Gulak, P. G. (2015) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2328318 · Cited by 115
“According to [52] the maximum allowed power density is 500 to keep temperature changes below 1 .”
Background
Metadata
- Authors
- Rabaey, J. M., Mark, M., Chen, D., Sutardja, C., Tang, C., Gowda, S., Wagner, M., & Werthimer, D.
- Venue
- 2011 Design, Automation & Test in Europe
- Publisher
- IEEE
- Published
- 2011-03
- Pages
- 1-6
- OpenAlex
- W2151445124
- Cited by
- 46
- References
- 4
- FWCI
- 6.52
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Powering and communicating with mm-size implants. https://app.cochat.ai/papers/10.1109/date.2011.5763123
- The paper
- Rabaey, J. M., Mark, M., Chen, D., Sutardja, C., Tang, C., Gowda, S., Wagner, M., & Werthimer, D. (2011). Powering and communicating with mm-size implants. 2011 Design, Automation & Test in Europe. https://doi.org/10.1109/date.2011.5763123
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.