CoChat

Behavior of a five-phase surface-mounted permanent magnet motor under magnet demagnetization

Casadei, Domenico, Mengoni, Michele, Serra, Giovanni, Tani, Angelo, Zarri, Luca · 2011 · 8th IEEE Symposium on Diagnostics for Electrical Machines, Power Electronics & Drives
Cited by 18

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The condition monitoring of magnets status in permanent magnet synchronous motors is critical for industrial applications, and then it is receiving more and more attention. Multiphase motor drives are an attractive technology for high power applications. They have many degrees of freedom that can be used for many purposes, such as power density improvement, monitoring, and so on. In this paper, a characterization of rotor faults for five-phase surface-mounted permanent magnet synchronous motors is presented. The considered rotor fault is the demagnetization of the rotor magnet trailing edges, due to large stator currents. The non-invasive detection method is based on a Fourier transform of the back-emf induced in the α-β planes, and exploits the large number of degrees of freedom of a multiphase motor drive. The proposed approach is validated by means of a finite element analysis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/demped.2011.6063634

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Research works printed but not linked: 10

  1. 10.1109/TPEL.2006.886620 · DOI · Paper page
  2. haylock, 2006, Predicting and preventing demagnetization in permanent magnet motor drives, Proc Power Electronics Machines and Drives Conf, 474
  3. 10.1109/TIA.2007.900444 · DOI · Paper page
  4. 10.1109/ISIE.2008.4677217 · DOI · Paper page
  5. 10.1109/SLED.2010.5542805 · DOI
  6. 10.1109/TIA.2004.841021 · DOI · Paper page
  7. casadei, 2009, Magnets faults characterization for permanent magnet synchronous motors, Proc IEEE International Symposium on Diagnostics for Electric Machines Power Electronics and Drives SDEMPED, 1, 10.1109/DEMPED.2009.5292770 · DOI · Paper page
  8. 10.1049/iet-epa:20060342 · DOI · Paper page
  9. 10.1109/IEMDC.2005.195920 · DOI
  10. 10.1109/IECON.2005.1569139 · DOI · Paper page

Cited by

See all 18

Metadata

Authors
Casadei, D., Mengoni, M., Serra, G., Tani, A., & Zarri, L.
Venue
8th IEEE Symposium on Diagnostics for Electrical Machines, Power Electronics & Drives
Publisher
IEEE
Published
2011-09
Pages
265-271
OpenAlex
W1989723878
Cited by
18
References
1
FWCI
2.61
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Behavior of a five-phase surface-mounted permanent magnet motor under magnet demagnetization. https://app.cochat.ai/papers/10.1109/demped.2011.6063634
The paper
Casadei, D., Mengoni, M., Serra, G., Tani, A., & Zarri, L. (2011). Behavior of a five-phase surface-mounted permanent magnet motor under magnet demagnetization. 8th IEEE Symposium on Diagnostics for Electrical Machines, Power Electronics & Drives. https://doi.org/10.1109/demped.2011.6063634

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.