Performance evaluation of 15 kV SiC IGBT based medium voltage grid connected three-phase three-level NPC converter
The DOI matches its Crossref record; 19 of the 20 references it cites were found in a registry or an index.
Abstract
Cascaded converters are generally used for Medium Voltage (MV) grid connected applications due to the limitation in the voltage rating of available Silicon (Si) power devices. These converters find application in Active Power Filters, STATCOM or as Active Front End Converters for Solid State Transformers at the distribution voltage levels. The wide bandgap semiconductor devices have enabled the grid connected operation of non-cascaded converters. This results in high power density, less number of switching devices, high efficiency and control simplicity for three-phase MV grid interface. 15 kV SiC IGBT is one such device which can be switched at 5 kHz between MV and zero levels with forced air cooling. However, this device in a grid connected non-cascaded converter introduces few additional challenges which are analyzed in this paper. The paper investigates the performance of the grid connected converter using 15 kV SiC IGBT through simulations and experiments till 4.16 kV, 3-phase operation. The concerned areas of study are Total Harmonic Distortion (THD) at low currents, effect of practical sensor-feedback path errors, effect of switching ripple on the distribution transformer, effect of filter parasitic capacitance and elimination of high common mode current.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Characterization, Modeling, and Application of 10-kV SiC MOSFET
Wang, J., Zhao, T., Li, J., Huang, A. Q., Callanan, R., Husna, F., & Agarwal, A. (2008) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2008.926650 · Cited by 398
Madhusoodhanan, S., Tripathi, A., Patel, D., Mainali, K., Kadavelugu, A., Hazra, S., Bhattacharya, S., & Hatua, K. (2015) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2015.2412096 · Cited by 371 · cited 3×
“Thus, instead of using a single 140 mH inductor per phase, series connection of small inductors is considered for the design [12].”
BackgroundSelf-citationDuffey, C. K., & Stratford, R. P. (1989) · IEEE Transactions on Industry Applications · doi:10.1109/28.44238 · Cited by 364
Fazel, S. S., Bernet, S., Krug, D., & Jalili, K. (2007) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2007.900476 · Cited by 356
Das, M. K., Capell, C., Grider, D. E., Leslie, S., Ostop, J., Raju, R., Schutten, M., Nasadoski, J., & Hefner, A. (2011) · 2011 IEEE Energy Conversion Congress and Exposition · doi:10.1109/ecce.2011.6064129 · Cited by 226
Akagi, H., Fujita, H., Yonetani, S., & Kondo, Y. (2008) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2008.916713 · Cited by 192
Characterization of 15 kV SiC n-IGBT and its application considerations for high power converters
Kadavelugu, A., Bhattacharya, S., Ryu, S.-H., Van Brunt, E., Grider, D., Agarwal, A., & Leslie, S. (2013) · 2013 IEEE Energy Conversion Congress and Exposition · doi:10.1109/ecce.2013.6647027 · Cited by 108
Self-citationTransformer less Intelligent Power Substation design with 15kV SiC IGBT for grid interconnection
Hatua, K., Dutta, S., Tripathi, A., Baek, S., Karimi, G., & Bhattacharya, S. (2011) · 2011 IEEE Energy Conversion Congress and Exposition · doi:10.1109/ecce.2011.6064346 · Cited by 88
Self-citationMadhusoodhanan, S., Hatua, K., Bhattacharya, S., Leslie, S., Ryu, S.-H., Das, M., Agarwal, A., & Grider, D. (2012) · 2012 IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2012.6342807 · Cited by 80
Self-citationWang, F., Wang, G., Huang, A., Yu, W., & Ni, X. (2014) · 2014 IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2014.6954024 · Cited by 77
Design and comparison of medium voltage multi-level converters for industry applications
Krug, D., Malinowski, M., & Bernet, S. (2004) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias.2004.1348503 · Cited by 75
Zhu, N., Kang, J., Xu, D., Wu, B., & Xiao, Y. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2162748 · Cited by 60
High performance, ultra high voltage 4H-SiC IGBTs
Ryu, S., Capell, C., Cheng, L., Jonas, C., Gupta, A., Donofrio, M., Clayton, J., O’Loughlin, M. J., Burk, A. A., Grider, D. E., et al. (2012) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2012.6342311 · Cited by 57
Self-citationRothmund, D., Ortiz, G., & Kolar, J. W. (2014) · 2014 IEEE 36th International Telecommunications Energy Conference (INTELEC) · doi:10.1109/intlec.2014.6972199 · Cited by 57
Experimental switching frequency limits of 15 kV SiC N-IGBT module
Kadavelugu, A., Bhattacharya, S., Ryu, S., Brunt, E. V., Grider, D. E., & Leslie, S. G. (2014) · International Power Electronics Conference (IPEC) · doi:10.1109/ipec.2014.6870034 · Cited by 35
Self-citationMadhusoodhanan, S., Bhattacharya, S., & Hatua, K. (2013) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2013.6647331 · Cited by 29
Self-citationMedium voltage power converter design and demonstration using 15 kV SiC N-IGBTs
Kadavelugu, A., Mainali, K., Patel, D., Madhusoodhanan, S., Tripathi, A., Hatua, K., Bhattacharya, S., Ryu, S., Grider, D., & Leslie, S. (2015) · Applied Power Electronics Conference · doi:10.1109/apec.2015.7104530 · Cited by 27
Self-citationGrid connected CM noise considerations of a three-phase multi-stage SST
Tripathi, A. K., Madhusoodhanan, S., Mainali, K., Kadavelugu, A., Patel, D. C., Bhattacharya, S., & Hatua, K. (2015) · International Conference on Power Electronics and ECCE Asia (ICPE-ECCE Asia) · doi:10.1109/icpe.2015.7167873 · Cited by 18
Self-citationMadhusoodhanan, S., Bhattacharya, S., & Hatua, K. (2014) · 2014 IEEE Applied Power Electronics Conference and Exposition - APEC 2014 · doi:10.1109/apec.2014.6803424 · Cited by 14
Self-citation
Cited by
Hannan, M. A., Ker, P. J., Lipu, M. S. H., Choi, Z. H., Rahman, M. S. A., Muttaqi, K. M., & Blaabjerg, F. (2020) · IEEE Access · doi:10.1109/access.2020.2967345 · Cited by 339
Zhang, X., Li, H., Brothers, J. A., Fu, L., Perales, M., Wu, J., & Wang, J. (2016) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2016.2586107 · Cited by 143
A 15-kV class intelligent universal transformer for utility applications
Lai, J.-S., Lai, W.-H., Moon, S.-R., Zhang, L., & Maitra, A. (2016) · 2016 IEEE Applied Power Electronics Conference and Exposition (APEC) · doi:10.1109/apec.2016.7468139 · Cited by 88
Abu-Siada, A., Budiri, J., & Abdou, A. (2018) · Electronics · doi:10.3390/electronics7110298 · Cited by 69
Zhang, X., Li, H., Brothers, J., Wang, J., Fu, L.-X., Perales, M., & Wu, J. (2016) · Applied Power Electronics Conference · doi:10.1109/apec.2016.7468138 · Cited by 37
Metadata
- Authors
- Madhusoodhanan, S., Mainali, K., Tripathi, A., Patel, D., Kadavelugu, A., Bhattacharya, S., & Hatua, K.
- Affiliations
- North Carolina State University (US)
- Indian Institute of Technology Madras (IN)
- Venue
- 2015 IEEE Energy Conversion Congress and Exposition (ECCE)
- Publisher
- IEEE
- Published
- 2015-09
- Pages
- 3710-3717
- OpenAlex
- W1940500377
- Cited by
- 13
- References
- 20
- Citations by year
- 2025: 1 · 2024: 1 · 2022: 1 · 2020: 2 · 2019: 1 · 2018: 3 · 2016: 4
- FWCI
- 2.89
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- IEEE Energy Conversion Congress and Exposition (ECCE) (publishedVersion)
- Funders
- National Science Foundation
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Silicon Carbide Semiconductor Technologies
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Quality and Harmonics
- Keywords
- SiC IGBT, medium-voltage grid connection, three-level neutral point clamped converter, wide bandgap semiconductors, total harmonic distortion, switching ripple, distribution transformers, common-mode current, active front-end converter, solid-state transformer, STATCOM
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.