Blood pressure estimation from pulse wave velocity measured on the chest
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Recently, monitoring of blood pressure fluctuation in the daily life is focused on in the hypertension care area to predict the risk of cardiovascular and cerebrovascular disease events. In this paper, in order to propose an alternative system to the existed ambulatory blood pressure monitoring (ABPM) sphygmomanometer, we have developed a prototype of small wearable device consisting of electrocardiogram (ECG) and photopelthysmograph (PPG) sensors. In addition, it was examined whether blood pressure can be estimated based on pulse wave transit time (PWTT) only by attaching that device on the surface of the chest. We indicated that our system could also sense tendency of time-dependent change of blood pressure by measuring pulse of vessel over the sternum while its propagation distance is short.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
The advantages of wearable green reflected photoplethysmography
Maeda, Y., Sekine, M., & Tamura, T. (2011) · Journal of Medical Systems · doi:10.1007/s10916-010-9506-z · Cited by 209
McCombie, D. B., Reisner, A. T., & Asada, H. H. (2006) · 2006 International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2006.260590 · Cited by 118
Cited by
Wearable Sensors for Remote Health Monitoring
Majumder, S., Mondal, T., & Deen, M. (2017) · Sensors · doi:10.3390/s17010130 · Cited by 1,375
Wearable health devices-vital sign monitoring, systems and technologies
Dias, D., & Paulo Silva Cunha, J. (2018) · Sensors · doi:10.3390/s18082414 · Cited by 919
“One is to estimate BP based on pulse wave transit time between the pulse wave obtained by photoplethysmography (PPG) and ECG (R-peak), both measured on the chest [25] or with the PPG signal acquired on the wrist [16].”
MethodRelation between blood pressure and pulse wave velocity for human arteries
Ma, Y., Choi, J., Hourlier-Fargette, A., Xue, Y., Chung, H. U., Lee, J. Y., Wang, X., Xie, Z., Kang, D., Wang, H., et al. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1814392115 · Cited by 309
Novel Methods for Pulse Wave Velocity Measurement
Pereira, T., Correia, C., & Cardoso, J. (2015) · Journal of Medical and Biological Engineering · doi:10.1007/s40846-015-0086-8 · Cited by 284
Optimising sampling rates for accelerometer-based human activity recognition
Khan, A., Hammerla, N., Mellor, S., & Plötz, T. (2016) · Pattern Recognition Letters · doi:10.1016/j.patrec.2016.01.001 · Cited by 171
Metadata
- Authors
- Puke, S., Suzuki, T., Nakayama, K., Tanaka, H., & Minami, S.
- Venue
- 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Publisher
- IEEE
- Published
- 2013-07
- Volume
- 2013
- Pages
- 6107-6110
- OpenAlex
- W2012880495
- Cited by
- 60
- References
- 3
- FWCI
- 9.90
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Blood pressure estimation from pulse wave velocity measured on the chest. https://app.cochat.ai/papers/10.1109/embc.2013.6610946
- The paper
- Puke, S., Suzuki, T., Nakayama, K., Tanaka, H., & Minami, S. (2013). Blood pressure estimation from pulse wave velocity measured on the chest. 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC). https://doi.org/10.1109/embc.2013.6610946
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.