Cited by 18Neurological disorders and treatmentsMuscle activation and electromyography studiesMotor Control and Adaptation

Development of a closed-loop system for tremor suppression in patients with Parkinson's disease

Xu, F. L., Hao, M. Z., Xu, S. Q., Hu, Z. X., Xiao, Q., Lan, N.·2016·2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)

Abstract

More than 70% of patients suffering Parkinson's disease (PD) exhibit resting tremor in their extremities, hampering their ability to perform daily activities. Based on our earlier studies on corticospinal transmission of tremor signals [10,11], we hypothesize that cutaneous afferents evoked by surface stimulation can produce an inhibitory effect on propriospinal neurons (PN), which in turn will suppress tremor signals passing through the PN. This paper presents the development of a closed-loop system for tremor suppression by transcutaneous electrical nerve stimulation (TENS) of sensory fibers beneath the skin. The closed-loop system senses EMGs of forearm muscles, and detects rhythmic bursting in the EMG signal. When a tremor is detected by the system, a command signal triggers a stimulator to output a train of bi-phasic, current regulated pulses to a pair of surface electrodes. The stimulation electrode is placed on the dorsal hand skin near the metacarpophalangeal joint of index finger, which is innervated by the superficial radial nerve that projects an inhibitory afferent to PNs of forearm muscles. We tested the closed-loop system in 3 normal subjects to verify the algorithm and in 2 tremor dominated PD subjects for feasibility of tremor detecting and suppression. Preliminary results indicate that the closed-loop system can detect tremor in all subjects, and tremor in PD patients was suppressed significantly by electrical stimulation of cutaneous afferents.

Integrity signals

Registry

Crossref · 10.1109/embc.2016.7591063

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Hao et al.'s surface electrical stimulation on the dorsal hand in eight PD patients reduced average peak spectral amplitude by 61.6 ± 8.9% and average EMG activity by 47.9 ± 25.8%.

    “Although tremulous movements and EMG signals seemed to be increased in some trials due to the stimulation, both metrics decreased their severity in most cases, resulting in an average peak spectral amplitude reduction of 61.6 ± 8.9% and an average EMG activity reduction of 47.9 ± 25.8%.”

    From A Review on Wearable Technologies for Tremor Suppression (2021) · cites this paper as [80]

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Xu, F. L., Hao, M. Z., Xu, S. Q., Hu, Z. X., Xiao, Q., & Lan, N.
Affiliations
Shanghai Jiao Tong University (CN)
Venue
2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
Publisher
IEEE
Published
2016-08
Volume
2016
Pages
1782-1785
ISSN
2375-7477 (ISSN-L)
OpenAlex
W2532054287
Cited by
18
References
13
Citations by year
2025: 2 · 2024: 2 · 2023: 4 · 2022: 4 · 2021: 2 · 2020: 2 · 2019: 2
FWCI
5.06
Type
conference paper
Language
en
Open access
closed
Locations
  • Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Neurology › Neurological disorders and treatments
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
Keywords
Parkinson's disease, resting tremor, tremor suppression, closed-loop stimulation, transcutaneous electrical nerve stimulation, cutaneous afferents, propriospinal neurons, superficial radial nerve, sensory feedback
MeSH terms
Electric Stimulation, Electromyography, Forearm, Humans, Parkinson Disease, Tremor, Muscle, Skeletal

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review