Monitoring and detecting atrial fibrillation using wearable technology
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Atrial fibrillation (AFib) is diagnosed by analysis of the morphological and rhythmic properties of the electrocardiogram. It was recently shown that accurate detection of AFib is possible using beat-to-beat interval variations. This raises the question of whether AFib detection can be performed using a pulsatile waveform such as the Photoplethysmogram (PPG). The recent explosion in use of recreational and professional ambulatory wrist-based pulse monitoring devices means that an accurate pulse-based AFib screening algorithm would enable large scale screening for silent or undiagnosed AFib, a significant risk factor for multiple diseases. We propose a noise-resistant machine learning approach to detecting AFib from noisy ambulatory PPG recorded from the wrist using a modern research watch-based wearable device (the Samsung Simband). Ambulatory pulsatile and movement data were recorded from 46 subjects, 15 with AFib and 31 non symptomatic. Single channel electrocardiogram (ECG), multi-wavelength PPG and tri-axial accelerometry were recorded simultaneously at 128 Hz from the non-dominant wrist using the Simband. Recording lengths varied from 3.5 to 8.5 minutes. Pulse (beat) detection was performed on the PPG waveforms, and eleven features were extracted based on beat-to-beat variability and waveform signal quality. Using 10-fold cross validation, an accuracy of 95 % on out-of-sample data was achieved, with a sensitivity of 97%, specificity of 94%, and an area under the receiver operating curve (AUROC) of 0.99. The described approach provides a noise-resistant, accurate screening tool for AFib from PPG sensors located in an ambulatory wrist watch. To our knowledge this is the first study to demonstrate an algorithm with a high enough accuracy to be used in general population studies that does not require an ambulatory Holter electrocardiographic monitor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Atrial fibrillation as an independent risk factor for stroke: the Framingham study
Wolf, P. A., Abbott, R. D., & Kannel, W. B. (1991) · Stroke · doi:10.1161/01.str.22.8.983 · Cited by 7,388
Miyasaka, Y., Barnes, M. E., Gersh, B. J., Cha, S. S., Bailey, K. R., Abhayaratna, W. P., Seward, J. B., & Tsang, T. S. M. (2006) · Circulation · doi:10.1161/circulationaha.105.595140 · Cited by 2,564 · cited 1×
“the adult population [1] that is projected to exceed 4% by 2050 [2].”
BackgroundSubclinical atrial fibrillation and the risk of stroke
Healey, J. S., Connolly, S. J., Gold, M. R., Israel, C. W., Van Gelder, I. C., Capucci, A., Lau, C. P., Fain, E., Yang, S., Bailleul, C., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1105575 · Cited by 2,100 · cited 1×
“AFib is often described as a ’silent killer’ because it increases the risk of ischemic stroke by 5-fold [3], yet remains asymptomatic in nearly a third of the AFib population [4], [5], [6].”
BackgroundMass Screening for Untreated Atrial Fibrillation: The STROKESTOP Study
Svennberg, E., Engdahl, J., Al-Khalili, F., Friberg, L., Frykman, V., & Rosenqvist, M. (2015) · Circulation · doi:10.1161/circulationaha.114.014343 · Cited by 605
PULSE‐SMART: Pulse‐Based Arrhythmia Discrimination Using a Novel Smartphone Application
McMANUS, D. D., CHONG, J. W., SONI, A., SACZYNSKI, J. S., ESA, N., NAPOLITANO, C., DARLING, C. E., BOYER, E., ROSEN, R. K., FLOYD, K. C., et al. (2016) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.12842 · Cited by 156 · cited 1×
“More recent studies have utilized PPG measured from smart-phone cameras [12], but algorithms tailored for existing wearable devices are less well-developed.”
BackgroundAronsson, M., Svennberg, E., Rosenqvist, M., Engdahl, J., Al-Khalili, F., Friberg, L., Frykman-Kull, V., & Levin, L.-Å. (2015) · Europace · doi:10.1093/europace/euv083 · Cited by 154 · cited 1×
“Classical solutions for AFib screening include hand-held ECG devices, used periodically over multiple weeks [8], [9].”
BackgroundSmart-watches: a potential challenger to the implantable loop recorder?
Carpenter, A., & Frontera, A. (2016) · Europace · doi:10.1093/europace/euv427 · Cited by 86 · cited 1×
“As wearable technologies become increasingly affordable and utilized by the general public, AFib detection algorithms that use photoplethysmography (PPG), now serve as an attractive alternative to existing ECG-based solutions [10].”
Background
Cited by
Hindricks, G., Potpara, T., Dagres, N., Arbelo, E., Bax, J. J., Blomström-Lundqvist, C., Boriani, G., Castella, M., Dan, G.-A., Dilaveris, P. E., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehaa612 · Cited by 9,971
Passive Detection of Atrial Fibrillation Using a Commercially Available Smartwatch
Tison, G. H., Sanchez, J. M., Ballinger, B., Singh, A., Olgin, J. E., Pletcher, M. J., Vittinghoff, E., Lee, E. S., Fan, S. M., Gladstone, R. A., et al. (2018) · JAMA Cardiology · doi:10.1001/jamacardio.2018.0136 · Cited by 566
Photoplethysmography based atrial fibrillation detection: a review
Pereira, T., Tran, N., Gadhoumi, K., Pelter, M. M., Do, D. H., Lee, R. J., Colorado, R., Meisel, K., & Hu, X. (2020) · npj Digital Medicine · doi:10.1038/s41746-019-0207-9 · Cited by 300
“Some studies used CNNs only for automatic feature extraction.51 In one study, an aggregated model of two serially connected CNNs was proposed, where the former detects clean segments from which the latter identifies instances of AF.51 Some DL models were trained with hybrid input data (i.e., time series and images) in…”
MethodInfluentialWearable sensors enable personalized predictions of clinical laboratory measurements
Dunn, J., Kidzinski, L., Runge, R., Witt, D., Hicks, J. L., Schüssler-Fiorenza Rose, S. M., Li, X., Bahmani, A., Delp, S. L., Hastie, T., et al. (2021) · Nature Medicine · doi:10.1038/s41591-021-01339-0 · Cited by 244
The WATCH AF trial: SmartWATCHes for detection of atrial fibrillation
Dörr, M., Nohturfft, V., Brasier, N., Bosshard, E., Djurdjevic, A., Gross, S., Raichle, C. J., Rhinisperger, M., Stöckli, R., & Eckstein, J. (2019) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2018.10.006 · Cited by 245
How useful is the smartwatch ECG?
Isakadze, N., & Martin, S. S. (2020) · Trends in Cardiovascular Medicine · doi:10.1016/j.tcm.2019.10.010 · Cited by 234
Self-citationNoseworthy, P. A., Kaufman, E. S., Chen, L. Y., Chung, M. K., Elkind, M. S. V., Joglar, J. A., Leal, M. A., McCabe, P. J., Pokorney, S. D., Yao, X., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000740 · Cited by 171
Atrial fibrillation and stroke prevention: 25 years of research at EP Europace journal
Lip, G. Y. H., Proietti, M., Potpara, T., Mansour, M., Savelieva, I., Tse, H. F., Goette, A., Camm, A. J., Blomstrom-Lundqvist, C., Gupta, D., et al. (2023) · Europace · doi:10.1093/europace/euad226 · Cited by 164
A deep learning approach to monitoring and detecting atrial fibrillation using wearable technology
Shashikumar, S. P., Shah, A. J., Li, Q., Clifford, G. D., & Nemati, S. (2017) · 2017 IEEE EMBS International Conference on Biomedical & Health Informatics (BHI) · doi:10.1109/bhi.2017.7897225 · Cited by 164
Self-citationSmart Wearables for the Detection of Cardiovascular Diseases: A Systematic Literature Review
Moshawrab, M., Adda, M., Bouzouane, A., Ibrahim, H., & Raad, A. (2023) · Sensors · doi:10.3390/s23020828 · Cited by 120
“[47] 2017 Atrial Fibrillation Electrocardiogram Photoplethysmogram Samsung Simband wrist band smart watch Convolutional Neural Network Elastic Net Logistic model Private Data Accuracy: 91.”
BackgroundAtrial fibrillation detection from wrist photoplethysmography signals using smartwatches
Bashar, S. K., Han, D., Hajeb-Mohammadalipour, S., Ding, E., Whitcomb, C., McManus, D. D., & Chon, K. H. (2019) · Scientific Reports · doi:10.1038/s41598-019-49092-2 · Cited by 120
Mobile health applications for the detection of atrial fibrillation: a systematic review
Lopez Perales, C. R., Van Spall, H. G. C., Maeda, S., Jimenez, A., Laţcu, D. G., Milman, A., Kirakoya-Samadoulougou, F., Mamas, M. A., Muser, D., & Casado Arroyo, R. (2021) · EP Europace · doi:10.1093/europace/euaa139 · Cited by 77
Varma, N., Cygankiewicz, I., Turakhia, M. P., Heidbuchel, H., Hu, Y.-F., Chen, L. Y., Couderc, J.-P., Cronin, E. M., Estep, J. D., Grieten, L., et al. (2021) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.120.009204 · Cited by 74
“…of a band that includes a single-channel ECG, multiwavelength photoplethysmography, and triaxial accelerometry recording simultaneously at 128 Hz (Nemati 2016),60 and others use a deep neural network based on photoplethysmography sensors to detect AF (https://…”
BackgroundEerikäinen, L. M., Bonomi, A. G., Schipper, F., Dekker, L. R. C., Vullings, R., de Morree, H. M., & Aarts, R. M. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aad2c0 · Cited by 61
“One option could also be to incorporate movement or signal quality information to the classification model as a feature (Nemati et al. 2016)(Shashikumar et al. 2017) to further improve accuracy and increase coverage.”
BackgroundDetection of atrial fibrillation using a wrist-worn device
Sološenko, A., Petrėnas, A., Paliakaitė, B., Sörnmo, L., & Marozas, V. (2019) · Physiological Measurement · doi:10.1088/1361-6579/ab029c · Cited by 45
Elevated body temperature is associated with depressive symptoms: results from the TemPredict Study
Mason, A. E., Kasl, P., Soltani, S., Green, A., Hartogensis, W., Dilchert, S., Chowdhary, A., Pandya, L. S., Siwik, C. J., Foster, S. L., et al. (2024) · Scientific Reports · doi:10.1038/s41598-024-51567-w · Cited by 31
“The TemPredict Study 26,27 was a prospective, worldwide, cohort study that continuously collected physiological metrics (e.g., body temperature) using an off-the-shelf wearable device (Oura Ring) with the primary aim of developing an algorithm to identify the onset of COVID-19.”
Eerikäinen, L. M., Bonomi, A. G., Dekker, L. R. C., Vullings, R., & Aarts, R. M. (2020) · Cardiovascular Digital Health Journal · doi:10.1016/j.cvdhj.2020.03.001 · Cited by 24
“These features have been used by setting thresholds to determine whether AF is present,(30,39,40) or they have been combined with machine learning to classify the rhythm.(19,20,22,27) The IBI series also has been evaluated”
Method
Metadata
- Authors
- Nemati, S., Ghassemi, M. M., Ambai, V., Isakadze, N., Levantsevych, O., Shah, A., & Clifford, G. D.
- Venue
- 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Publisher
- IEEE
- Published
- 2016-08
- Volume
- 2016
- Pages
- 3394-3397
- OpenAlex
- W2533802684
- Cited by
- 145
- References
- 7
- FWCI
- 26.60
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.